background image

Tools required: 

Components required: 

UL approved 18 AWG (0.82mm 

) supply

wire 

End caps 

Light guide connectors  

Mounting clips  

Weather box 

22 AWG (0.33mm

2

) tie-wire 

#8 & #10 (M3 or M4) self drilling pan  
head screws  

#6 (M2) screws 

UL approved 22-14 AWG (0.33-2.08mm 

twist-on wire connectors  

Tetra  24 Volt Power Supply

Tetra Contour light engine

Tetra Contour light guide

Tools and Components 

* NOTE: xx = color code 

10 

11

12

(GERDXNLE1, GERCXNLE1, GEYAXNLE1, GEGLXNLE1, GEBLXNLE1, GEWHXNLE1, GEWWXNLE1) 

Installation Guide 

Tetra

®

Contour 

LED Lighting System 

GE 

Lighting Solutions

24 

Volt 

imagination at work 

10 

11 

12 

Wire stripper/cutter 

Tape measure 

 Screwdriver 

Electrical grade silicone 

Cordless drill 

®

Summary of Contents for Tetra Contour

Page 1: ...4 Volt Power Supply Tetra Contour light engine Tetra Contour light guide Tools and Components 1 2 3 4 5 6 7 8 NOTE xx color code 9 10 11 12 GERDXNLE1 GERCXNLE1 GEYAXNLE1 GEGLXNLE1 GEBLXNLE1 GEWHXNLE1 GEWWXNLE1 Installation Guide Tetra Contour LED Lighting System GE Lighting Solutions 24 Volt imagination at work m 4 4 2 t e e f 8 1 2 4 7 9 5 m 4 4 2 t e e f 8 3 10 11 12 8 1 2 4 3 5 Wire stripper cu...

Page 2: ... behind light engines 6 5 CAUTION Anytime light engine or supply wire is cut and wire is exposed electrical grade silicone must be applied see list on the next page for recommendations METHOD B with light guides 2 Push into clips If required cut wire loops between sections or through light engine refer to the Cutting Resolution table above NOTE Installation methods shown are for straight runs For ...

Page 3: ...one Connect two negatives Connect four positives Separate wires 7 Insert wire connectors into weather box Fill with electrical grade silicone and close box Weather box can be mounted using 8 M3 screws NOTE Weather box is required for all outdoor electrical connections Weather box can be painted Connect Power Supply Run a wire from the power supply to a section of Tetra Contour NOTE Power supply co...

Page 4: ...osure BWdc UU _ wer at fuse box or circuit breaker before installation RISK OF FIRE 5 f P 42 P S RP R STb DbT h D P__roved wire for input output connections Minimum size 18 AWG 0 82mm2 Optional Attaching Tetra Contour to Tetra Contour LS 2 Splice the white wire with red stripe of Tetra Contour LS to the two outside wires of Tetra Contour and splice the white wire of Tetra Contour LS to the center ...

Reviews: