4

Option: power input from side – Remove knockout 

in endcap and A) Install 1/2” conduit, or B) install 

AC power cord with strain relief. Plug unused hole 

on top with appropriate fitting.

120-277V: Connect the green (ground), black (line) 

and white (neutral) wires of the AC line to the 

similarly colored wires of the fixture’s power supply 

using UL listed wire connectors. Re-attach endcap.
347-480V: Connect the green (ground), red (line) 

and black (neutral) wires of the AC line to the 

similarly colored wires of the fixture’s power supply 

using UL listed wire connectors. Re-attach endcap.

When ordered as an option, continuous run fixtures use quick-connectors and keyhole fasteners to properly 

wire and align the joining fixtures.

A) Conduit

B) Power cord

3

4

Push the quick-connect assembly and excess 

wiring into the open end of one fixture end plate 

so only a small length of wire remains between 

joining fixtures.

Align keyholes with corresponding tabs and push 

fixtures together.

Continuous Run Installation

1

2

Completely hang the first fixture in the run. One 

end should be closed while the other end has 

quick-connect wiring. Using two people, hang the 

next fixture in the run, making sure to properly 

align quick-connectors.

Make all wiring connections between fixtures using 

the provided quick-connectors.

Closed end

First fixture in run

Open end

Summary of Contents for Albeo

Page 1: ...on électrique RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux N utilisez que des fils approuvés par UL ou IEC pour les entrées sorties de connexion Taille minimum 18 AWG Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer This device complies with part 15 of the FCC Rules Operation is subject to the followin...

Page 2: ...f the ceiling Fixture must be supported independently of an outlet box Loop chain cable through the two mounting brackets The mounting brackets come pre installed Loosen the screws to move the brackets to a desired location then re tighten Each mounting bracket can connect to a chain cable rod or be surface mounted Chain or Cable Mounting Carefully unpack unit and properly inspect for defects befo...

Page 3: ... wires from junction box to fixture wires see Step 4 under Electrical Connections for details Reattach lightbar to fixture and tighten screws Position the two mounting brackets at the ends of the fixture and tighten Attach the fixture to ceiling using appropriate hardware not supplied Ceiling Fixture wires Junction box Junction box AC line Open LED lightbar Move mounting brackets to ends Loosen sc...

Page 4: ...ndcap When ordered as an option continuous run fixtures use quick connectors and keyhole fasteners to properly wire and align the joining fixtures A Conduit B Power cord 3 4 Push the quick connect assembly and excess wiring into the open end of one fixture end plate so only a small length of wire remains between joining fixtures Align keyholes with corresponding tabs and push fixtures together Con...

Page 5: ...will not turn on Check that the color of the supply side wires match the color of the wires they are connected to Check that all wire connectors are properly connected Verify that your input voltage is within specs If you are using any additional controls i e wireless controls or motion sensors please also verify that those are working properly and that the unit is setup to interface with the cont...

Reviews: