NX-2192E PINPOINT SYSTEM
14
PROGRAMMING NODE INFORMATION FOR OUTPUTS 1 - 48
LOC
PAGE OUTPUT
Segment #1
Physical address
Segment #2
Output number
Segment #3
Error code
Notes
234
5
41
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
235
5
42
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
236
5
43
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
237
5
44
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
238
5
45
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
239
5
46
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
240
5
47
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
241
5
48
1 2 3 4 5 6 7 8
1 _ _ _ _ _ _ _
_
USE THE FOLLOWING TABLE FOR
EVEN NUMBERED LOCATIONS 242 – 336
(EVENT / TIME)
#
Event
#
Event
0
Always On
17
Alarm Memory
1
AC Fail (control or exp.) does
not follow AC Fail delay time
18 Entry
2
Low Battery (control or exp.)
19
Exit
3
Dynamic Battery Test Time
20
Entry or Exit
4 Listen
In
21 Armed
5 Line
Seizure
22 Disarmed
6
Telephone Line Fault
23
Ready to Arm
7
Program Mode
24
Not Ready to Arm
8
Over-current (control or exp.)
25
Fire
9
Box Tamper (control or exp.)
26
Fire Trouble
10 Siren Tamper (control or exp.)
27
Chime
11 Smoke Power Reset
28
Beeping Keypad
12 Yelping
Siren
29
♦
Aux 1 Keypad Function
13 Steady
Siren
30
♦
Aux 2 Keypad Function
14 Any
Siren
31
♦
Panic Keypad Function
15 Steady Siren (temporal)
32
♦
Code Entry ( locs 338 - 481)
16 Any Siren (temporal)
USE THE FOLLOWING TABLE FOR
ODD NUMBERED LOCATIONS 243 – 337
(SPECIAL FEATURES)
SEG 1
DESCRIPTION
SEG 2
DESCRIPTION
1 =
ON times in minutes
OFF if times in seconds
1 =
On if event activates output in
Partition 1
2 =
ON to latch until a code is
entered; OFF for timed
2 =
On if event activates output in
Partition 2
3 =
ON if output should stop time
when a code is entered
3 =
On if event activates output in
Partition 3
4 =
ON for inverted output
4 =
On if event activates output in
Partition 4
5 =
ON disables output during
listen-in (only events 12-16)
5 =
On if event activates output in
Partition 5
6 =
Reserved 6
=
On if event activates output in
Partition 6
7 =
Reserved 7
=
On if event activates output in
Partition 7
8 =
Reserved 8
=
On if event activates output in
Partition 8
LOC
PAGE
DESCRIPTION
SEG 1 DEFAULT
SEG 1 DATA
SEG 2 DEFAULT
SEG 2 DATA
242
6
EVENT / TIME – OUTPUT 1
14=Any Siren
0=Follow Evt
243
6
FEATURES – OUTPUT 1
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
244
6
EVENT / TIME – OUTPUT 2
14=Any Siren
0=Follow Evt
245
6
FEATURES – OUTPUT 2
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
246
6
EVENT / TIME – OUTPUT 3
14=Any Siren
0=Follow Evt
247
6
FEATURES – OUTPUT 3
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
248
6
EVENT / TIME – OUTPUT 4
14=Any Siren
0=Follow Evt
249
6
FEATURES – OUTPUT 4
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
250
6
EVENT / TIME – OUTPUT 5
14=Any Siren
0=Follow Evt
251
6
FEATURES – OUTPUT 5
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
252
6
EVENT / TIME – OUTPUT 6
14=Any Siren
0=Follow Evt
253
6
FEATURES – OUTPUT 6
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
254
6
EVENT / TIME – OUTPUT 7
14=Any Siren
0=Follow Evt
255
6
FEATURES – OUTPUT 7
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
256
6
EVENT / TIME – OUTPUT 8
14=Any Siren
0=Follow Evt
257
6
FEATURES – OUTPUT 8
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
258
6
EVENT / TIME – OUTPUT 9
14=Any Siren
0=Follow Evt
259
6
FEATURES – OUTPUT 9
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
260
6
EVENT / TIME – OUTPUT 10
14=Any Siren
0=Follow Evt
261
6
FEATURES – OUTPUT 10
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
262
6
EVENT / TIME – OUTPUT 11
14=Any Siren
0=Follow Evt
263
6
FEATURES – OUTPUT 11
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
264
6
EVENT / TIME – OUTPUT 12
14=Any Siren
0=Follow Evt
265
6
FEATURES – OUTPUT 12
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
266
6
EVENT / TIME – OUTPUT 13
14=Any Siren
0=Follow Evt
267
6
FEATURES – OUTPUT 13
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
268
6
EVENT / TIME – OUTPUT 14
14=Any Siren
0=Follow Evt
269
6
FEATURES – OUTPUT 14
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
270
6
EVENT / TIME – OUTPUT 15
14=Any Siren
0=Follow Evt
271
6
FEATURES – OUTPUT 15
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8
272
6
EVENT / TIME – OUTPUT 16
14=Any Siren
0=Follow Evt
273
6
FEATURES – OUTPUT 16
_ _ _ _ _ _ _ _
1 2 3 4 5 6 7 8