background image

4

ATP1000 Touchpad/Display Installation Instructions

3. Enter program mode by pressing 

8

 + installer/dealer 

CODE

 

0

 + 

0

 and program the 

panel using the panel 

Installation Instructions.

4. When programming is completed, simply disconnect the programming touchpad.

To connect a programming touchpad to a Concord panel with software versions 1.0–1.6:

1. Disconnect AC and backup battery power.
2. Connect the cable plug onto the panel Programming Touchpad Header pins (see Figure 5).
3. Reconnect the AC and backup battery power. The touchpad briefly displays ***********, 

SCANNING BUS DEVICES, 

then shows a time and date display.

Note  

If the touchpad does not respond as described in step 3, there may be a bus conflict. To correct this, 
change the touchpad unit number as described in the section “Changing the Touchpad Unit Number.”

Removing the programming touchpad from Concord panels with software versions 1.0–1.6:

To prevent a trouble condition, you must delete the programming touchpad unit number from 
Concord panel memory 

before

 disconnecting it.

1. After programming is completed, return to the 

ACCESSORY MODULES 

menu, then press 

ƒ

The display should read 

BUS DEVICES.

2. Press 

ƒ

. The display shows the lowest unit number and its device name.

3. Press 

A

 or 

B

 until the display shows the programming touchpad unit number.

4. Press 

D

 to delete the device and its unit number from panel memory. The display shows:

UNIT - TYPE
14-NONE

5. Exit program mode and disconnect the programming cable from the panel header.

Testing

Note  

Contact the central monitoring station before activating alarms, to avoid dispatching local police and fire 
departments.

Test the touchpad by arming/disarming the system, activating the touchpad panics, bypassing 
sensors, and by turning chime and lights on/off to verify correct operation. Refer to the panel 

User’s Manual

 

for complete system operating instructions.

Adjusting 
Display 
Brightness and 
Contrast

The touchpad display can be adjusted for easier viewing to help compensate for lighting condi-
tions in the touchpad location.

The brightness adjustment lightens or darkens the background. The contrast adjustment lightens 
or darkens the text.

To adjust display brightness:

1. Enter user programming mode by pressing 

9

 + 

user, partition, or system master 

CODE

The display shows 

SYSTEM MENU, 

then 

TIME AND DATE 

(Concord panels with software versions 1.0–1.6 display 

USER CODES.

)

2. Press 

B

 until the display shows 

OPTIONS

, then press 

ƒ

. The display shows 

DOWNLOAD-

ING ON/OFF (current setting)

.

3. Press 

twice and the display shows 

TOUCHPAD BRIGHTNESS 2

 (default setting).

4. Enter a setting from 

(darkest background) to 

3

 (brightest background), then press 

ƒ

.

5. The display flashes the entered selection, then stops after pressing 

ƒ

 and displays the new set-

ting and brightness level.

6. Exit user programming mode.

To adjust display contrast:

1.

Enter configuration mode by pressing the 

D

 and 

6

 buttons together for at least two seconds. 

The display shows 

DA nnn

.

2.

Press and release the 

1

 and 

2

 buttons together repeatedly, until the desired contrast level is 

displayed.

3.

Press 

 and the display briefly shows 

DONE

, then shows the time and date.

Summary of Contents for ATP1000

Page 1: ...ncluded Panhead screws for gang box installation Saw or utility knife for cutting wallboard Installation Guidelines Mount the touchpad in an environmentally controlled area 32 F to 120 F 0 C to 49 C When mounting the touchpad allow at least 3 inches below it for the swing down cover Do not exceed the maximum available power See the panel installation instructions for max imum available power Table...

Page 2: ... not overtighten screws or the mounting plate may bind and prevent the touchpad from mounting properly 5 For wall mount installations cut a hole in the wall in the wire access area of the mount ing plate to pull the wiring cable through Wiring the Touchpad to the Panel 1 Remove panel AC and backup battery power 2 Run a 4 conductor 18 to 22 gauge wire from the panel to the touchpad location see Tab...

Page 3: ...lay shows SYSTEM PROGRAMMING 9 Press A or B until the display shows EXIT PROGRAMMING READY then press ƒ The touchpad should show the date and time display Programming To program options for the newly installed touchpad such as key beeps see the specific panel installation instructions Connecting the Touchpad for System Programming Only For installations that don t include an alphanumeric touchpad ...

Page 4: ...from the panel header Testing Note Contact the central monitoring station before activating alarms to avoid dispatching local police and fire departments Test the touchpad by arming disarming the system activating the touchpad panics bypassing sensors and by turning chime and lights on off to verify correct operation Refer to the panel User s Manual for complete system operating instructions Adjus...

Page 5: ...splay shows DA n where n is the new touchpad unit number 4 Do not use unit number 15 in Concord RF systems 5 Press to exit from the configuration mode Note If the new touchpad unit number was previously learned by the panel communication between the touchpad and the panel begins immediately However if the new touchpad unit number has never been Table 3 Troubleshooting Problem Action Solution Touch...

Page 6: ...omplete UL installation requirements for the system you are installing Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Interlogix can void the user s authority to operate the equipment FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits...

Reviews: