background image

Wall Mounted 
Split Air-Conditioner

Owner’s Manual and Installation Instructions

GE Consumer & Industrial
Appliances

GE imagination at work

English

Summary of Contents for GE AIR 107

Page 1: ...Wall Mounted Split Air Conditioner Owner s Manual and Installation Instructions GE Consumer Industrial Appliances GE imagination at work English ...

Page 2: ...How to insert batteries 10 User notices 10 Care and maintenance 11 Troubleshooting 13 Installation instructions 15 Accessories and installation diagram 15 General installation instructions 16 Installing the indoor unit s 18 Installing the outdoor unit 23 Test operation and after installation check 25 Technical specifications 27 Models covered in this document GE GE AIR 107 GE AIR 109 GE AIR 112 GE ...

Page 3: ...alled at least 2 0 m from the ground Extreme temperature differentials can be harmful to health Do not use the air conditioner for drying clothes preserving foods or other functions for which it was not designed Splashing water on the unit may cause an electric shock and malfunction The ground earthing wire must be properly connected Do not connect the earth wire to a gas or water pipe lightning r...

Page 4: ...0 C HEAT mode not available on models GE AIR 326 and GE AIR 428 3 MODE button Select the desired mode of operation by pushing this button The unit can operate on AUTO COOL DRY FAN or HEAT modes Heat mode not available on models GE AIR 326 and GE AIR 428 4 FAN button Press this button to change fan speed There are three speeds to choose from or set the FAN to AUTO to let the unit control the air flo...

Page 5: ...control the speed of the indoor fan according to the target temperature HEAT mode operation not available on models GE AIR 326 and GE AIR 428 The microcomputer automatically controls the rate of heating It adjusts the operation of the unit according to the actual room temperature and the desired temperature If the room temperature is lower than the desired temperature the unit will heat the air of...

Page 6: ...emperature to save energy Keep the room approximately 5 C cooler than the outside temperature when operating in COOL mode Adjust the direction of the airflow appropriately Remember that warm air rises and cool air sinks so adjust the louver downward for heating and upward for cooling to take advantage of natural convection currents User notices CAUTION Always turn power off and remove the power plu...

Page 7: ...enter Please check for the following 1 Is a power connection loose 2 Is the circuit breaker activated 3 Is the voltage higher than 253 volts or lower than 198 volts 4 Is TIMER ON in operation 1 Is the set temperature suitable 2 Is the air inlet or outlet obstructed 3 Are the air filters dirty or clogged 4 Is the indoor fan speed set too low 5 Is there another heat source in the room 1 Is the remote...

Page 8: ... 2 5 4 5 Tapping screw 10 10 20 30 40 Plastic drain hose 1 1 2 3 4 Piping hole sleeve 2 2 4 6 8 Wrapping tape 1 1 2 3 4 Connection piping 1 1 2 3 4 Thermal insulation hose 1 1 2 3 4 Outdoor drain elbow 1 1 2 Outdoor drain stem 2 2 4 Air cleaner 2 2 4 6 8 Square ring 1 2 2 2 Immediately stop all operations disconnect the power and contact your nearest service center in the event any of the followin...

Page 9: ...er before beginning installation to avoid possible malfunctions When picking up and moving the unit be guided by trained and qualified personnel The ground connection of the air conditioner must be made correctly and securely to the recommended earth ground points Contact the service center if you have any question Installation in the following places may cause malfunction Any place where machine o...

Page 10: ...ter 11 Do not install the unit in the immediate vicinity of a laundry bath shower or swimming pool 12 The power plug must be accessible after the appliance is correctly positioned Install the rear panel 1 Always mount the rear panel horizontally 2 Fix the rear panel on the selected location with the screws supplied with the unit 3 Be sure the rear panel is firmly fixed The mounting must be able to w...

Page 11: ...d value to operate the air conditioner safely 7 Wiring work must conform to national standards Model GE AIR 107 GE AIR 109 GE AIR 112 PRO AIR 107 PRO AIR 109 PRO AIR 112 GE AIR 116 GE AIR 121 GE AIR 218 GE AIR 224 PRO AIR 218 GE AIR 326 GE AIR 428 PRO AIR I109 PRO AIR I112 Indoor terminal block N 2 4 5 ground N 2 3 4 5 N 2 3 ground N 1 2 3 ground N 1 2 3 ground Cable wire Blue black violet orange ...

Page 12: ...the connecting cable when fixing it with the wire clamp Make sure the wires are securely connected to the terminal block and the connecting cable is firmly held by the wire clamp Installing the outdoor unit Fig 3 Pipe diameter Torque mm Nm 6 35 15 20 9 52 31 35 12 7 50 55 15 8 60 65 Table 3 Install the piping hole 1 Make the piping hole Ø100 mm for models GE AIR 116 and GE AIR 121 and Ø80 mm for all...

Page 13: ...it is connected to the power grid or after a power cut AUTO TEST R U N STOP Air purging and leakage test For models with multiple indoor units this procedure must be executed for each indoor unit This procedure requires a manifold valve and a vacuum pump 1 Make sure the liquid side valve and gas side valve are set to the closed position and check pipes are connected properly 2 Remove service port ...

Page 14: ...in well Is the voltage in accordance with the rated voltage marked on the nameplate Is the electrical wiring and piping connection installed correctly and securely Has the ground connection been made securely to recommended earth ground points Is the power cord as specified Are the air inlet and outlet blocked Has the length of the connection pipe and the thermal capacity been verified Possible cons...

Page 15: ...770x250x180 770x250x180 770x250x180 907x290x195 907x290x195 770x250x180 770x250x180 770x250x180 770x250x180 Net weight outdoor unit kg 32 32 40 59 59 65 72 71 71 Unit dimensions outdoor unit mm wxhxd 848x540x260 848x540x260 848x540x260 950x700x340 950x840x340 950x700x340 950x840x340 950x840x340 950x840x340 All of the above information may be changed without notice The specifications on the nameplat...

Page 16: ...30 ...

Reviews: