Connection Examples
The fittings can be installed from an external supply in a number of
ways. If the units are to be on, simply connect the CTRL terminal to
the PWR terminal at the light fitting. If the unit is to be switched, a
switch can be placed between the CTRL and PWR terminal. The BS-
DM1 can be wired into the circuit for full dimming control.
The schematic above shows the use of a BS-PS1. In this example, the
fittings connected to O/P 1 will be controlled by the switch connected
to the switch input on the BS-PS1. They will also be affected by the
‘TOPSET’ control. This allows you to set the on level from 0-100%. By
connecting a BS-DM1 and removing the CTRL line from the power
supply, the second set of fittings can be dimmed using the BS-DM1.
These will not be affected by the switch on the BS-PS1.