Connection Examples 
 

The fittings can be installed from an external supply in a number of 
ways.  If the units are to be on, simply connect the CTRL terminal to 

the PWR terminal at the light fitting.  If the unit is to be switched, a 

switch can be placed between the CTRL and PWR terminal.  The BS-

DM1 can be wired into the circuit for full dimming control. 

 

 

The schematic above shows the use of a BS-PS1.  In this example, the 

fittings connected to O/P 1 will be controlled by the switch connected 

to the switch input on the BS-PS1.  They will also be affected by the 

‘TOPSET’ control.  This allows you to set the on level from 0-100%.  By 

connecting a BS-DM1 and removing the CTRL line from the power 

supply, the second set of fittings can be dimmed using the BS-DM1.  
These will not be affected by the switch on the BS-PS1. 