GDI GOLD X-FINDER Manual Download Page 5

 

Μ2: SILVER [Ag] 8700 Hz, Μ3: IRON [Fe] 16800 Hz, Μ4: LEAD [Pb] 4000 Hz, Μ5: ALUMINIUM [Al] 6800 Hz                                                                                                                      
Μ6: BRONZE 11800 Hz, Μ7: COPPER [Cu] 11200 Hz, Μ8: DIAMOND [C] 12200 Hz,                                                                                        
M9: WATER [H2O] 9500 Hz, M10: VOID 200 Hz, M11-M13*: FREE MODES 0 – 20000 Hz                                                               

( *free modes where the user stores manually -using the arrows- the preferred frequency  to experiment )   

FINE FREQUENCY TUNING 

By a single press of arrow key the element frequency                                                                                                                              
can be fine adjusted in steps of 1 Hz. Depress an arrow                                                                                                                                                      
key to adjust in steps of 100 Hz. It is worth to fine tune                                                                                                                                                  
the frequency slight higher or lower, to calibrate with                                                                                                                              
the operator conductivity, soil conditions and metal alloy                                                                                                                             
(for example gold karats). It is possible that various users notice small                                                                                                                               
changes to the frequencies they respond better. For that purpose move the frequency                                                                 
setting to a point more satisfactory to you. Correct frequency tuning results at intense                                               
antenna movement even prior to target line. Experiment with your own samples and                                                       
soil types. Put your own target sample over the ground, take care it makes a good                                                                                                      
contact alternatively wet with salt water. Alter the frequency and scan again.  Repeat                                                                            
as many times needed until the best response is received.  Note that some fresh targets                                                
have a weak or no response at all. Correct frequency tuning presents an intense antenna movement, 
starting before the target line and the antenna will lock to the target for a relatively large width.                                         
To 

reset all frequencies to the starting values

, hold the UP and MENU keys. The X-FINDER beeps 3 times 

and then makes a longer beep to confirm the reset. 

CENTERING THE TARGET 

Α. Triangulation method                                                                                                                                                      

Move 15 m. away sideways to the spot where the first reading is received and scan again. If an imaginary 
line is projected from the antenna at both spots, then those 2 lines intersect at the target center.                                   
In case the angle of the lines is closed the target is in a close proximity, if it is open, the target lies far away. 
Start moving towards the point of intersection. If you stand above and pass it, the antenna locks either                   
to the left or right side. 

 

 

 

 

 

 

 

 

 

 

Position 1                                                                                                            Position 2 

Target 

Triangulation method 

 

 

 

Summary of Contents for GOLD X-FINDER

Page 1: ...Long Range Locator Version 3 Firmware v1 06 May 2022 X FINDER youtube video guide https youtu be WkRnv9HlUDo users unexperienced to similar devices please note the conditions of operation at pages 2 3...

Page 2: ...the main unit telescopic antenna handle and 4 x AA batteries Pull the battery door and position the batteries in the correct order according the indications Extend the antenna to the desirable length...

Page 3: ...d practice sweeping at a normal speed not very slow as a stop and go action but a sweep at a constant movement Secondly lay sample targets over the ground surface outdoors as house has a lot many meta...

Page 4: ...e rest have to go through proper adjustment of their body and optimize their conductivity by practicing If another individual with a high body conductivity is with you let him amplify your adjustment...

Page 5: ...l types Put your own target sample over the ground take care it makes a good contact alternatively wet with salt water Alter the frequency and scan again Repeat as many times needed until the best res...

Page 6: ...selection screen press and hold simultaneously the DOWN and MENU keys The detection range is divided in 10 levels from low to high that are selectable using the arrow keys When selecting higher level...

Page 7: ...ION Once the target signal has been centered over a spot position sideways at 10 m distance a good amount of gold for example coins inside a net Let the samples over the ground surface or let them hal...

Page 8: ...iron lead aluminum copper bronze diamonds water cave voids 3 Free modes for user defined adjustable frequency version 1 06 VLF frequency range 0 20000 Hz Manual frequency tuning with 1 Hz fine precisi...

Page 9: ...9 GDI GEOPHYSICAL INSTRUMENTS 2022 193 Athinon avenue 12461 Athens Greece Tel 30 210 4905398 Web http www gdi detectors com...

Reviews: