You can program each port in your TeleCraft unit to have one of eight calling privileges.
Note that regardless of the restriction level, you cannot block calls to 911.
1.
No restrictions.
The port can make any call.
2.
Internal calls only.
The port can make internal (intercom) calls only. Any call that requires an external
line (except 911) is blocked.
3.
Allowed list 1.
Calls within your area code, and calls matching your allowed list 1 can proceed.
4.
Allowed list 2.
Calls within your area code, and calls matching your allowed list 2 can proceed.
5.
Allowed lists 1 and 2.
Calls within your area code, and calls matching your allowed list 1 or allowed list 2
can proceed.
6.
Disallowed list 1.
Calls matching your disallowed list 1 cannot proceed. You cannot block calls to 911.
7.
Disallowed list 2.
Calls matching your disallowed list 2 cannot proceed. You cannot block calls to 911.
8.
Disallowed lists 1 and 2.
Calls matching your disallowed list 1 or 2 cannot proceed. You cannot block calls to
911.
External line lists
You can compose 4 external line lists as follows.
•
Any list can include up to 6 external lines.
•
Any external line can be included in any list
•
Any external line can be included in more than one list.
Every port is associated with one of the external line lists for (a) making outside calls, and
(b) receiving calls from outside. A port can use the same list for incoming and out-going
calls, if desired.
External lines: out-
going calls
Every port is associated with one of the external line lists for the purpose of making
outside calls.
For example, port 00 may be associated with list 1, and port 01 may be associated with
list 2. List 1 may include all available external lines while list 2 may include external line 3
only. Thus port 00 has access to all external lines while port 01 is allowed to make out-
going calls only on external line number 3.
TeleCraft Telephone Systems