MECHANICAL INSTALLATION
Location Selection
Select suitable places to install Modules. The module in the north latitude region shall
face south, and shall face north in the south latitude region.
Install Modules at the places with sufficient sunlight and without shade at any time. If a
module is shaded or even partially shaded, it will result in lower power output. A
permanent or regular shade will cause module damage, which will result in the invalidity
of product’s limited warranty.
Do not store, install or use Modules at the places where combustible gas is easily
generated or gathering.
The straight-line distance between the installation site and coastline shall not be shorter
than 1 km unless there is a writ ten approval from GCLSI or an engagement specified in
the contract.
Location Selection
Modules in the same string should be installed at the same angle. Modules installed in
different angles will receive different irradiation, which will cause current different. As a
result, it will decrease the operation efficiency of the system.
Please refer to Table 1 for the recommended mounting tilt angles of the Modules.
Local latitude
Mounting Tilt Angles
0°-15°
15°
15°-25°
Local latitude
25°-30°
Local la 5°
30°-35°
Local la 10°
35°- 40°
Local la 15°
>
40°
Local la 20°
Table 1 Mounting Tilt Angle of Modules