background image

10

 / 

44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Num

 

Name

 

Description

 

1

 

Power Switch

 

Power ON/OFF Switch

 

2

 

Port

 

Charging Port

 

3

 

LCD

 

Display Information

 

4

 

Refresh (Button)

 

Refresh State

 

5

 

Select (Button)

 

Select Wavelength

 

6

 

Parameter (Button)

 

Select dB/mW

 

Summary of Contents for Ofix GP-1000

Page 1: ...1 44 OFIX V1 0 User s Manual...

Page 2: ...improvements to the instrument s performance and functions The figures given in this manual may differ from those that actually appear on your screen Every effort has been made in the preparation of...

Page 3: ...ving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Page 4: ...pp Android 1 8 OFIX Viewer PC 1 Num Module Description 1 OTDR module Standard SM1550 2 OPM optical power meter module Optional 3 OTDR module Optional SM1310 1625 1650 Standard Accessary OFIX standard...

Page 5: ...the proper protective eyewear In addition avoid being exposed to the laser light It can cause blindness or damage to the eye Do Not Remove Covers The covers should be removed by Company s qualified pe...

Page 6: ...p Connect 2 4 2 OFIX OTDR Mobile App Measure 2 4 3 OFIX OTDR Mobile App Analyze 2 4 4 OFIX OTDR Mobile App Setting 3 Preparation 3 1 Turn on OFIX 3 2 Connecting the Fiber 4 Introduction of OTDR 4 1 Pu...

Page 7: ...r Module Optional 9 Background Information on Measurements 9 1 Viewing the Optical Pulse Measurement Waveform 9 2 Terminology 10 Diagnosis Center 10 1 FAQ 11 Specification 11 1 Physical Parameter 11 2...

Page 8: ...ts are OTDR and optical power meters that are meant for short distance less than 25km optical cable maintenance that are expanding rapidly in the wire wireless communications market In the communicati...

Page 9: ...9 44 Names and Functions of Parts OFIX Interface 2 1 3 4 5 6 O F I X...

Page 10: ...44 Num Name Description 1 Power Switch Power ON OFF Switch 2 Port Charging Port 3 LCD Display Information 4 Refresh Button Refresh State 5 Select Button Select Wavelength 6 Parameter Button Select dB...

Page 11: ...11 44 OFIX LCD 2 1 4 5 6 7 3...

Page 12: ...12 44 Num Name Display 1 OFIX Reading State 2 OTDR OTDR MODE 3 OPM OPM MODE 4 Bluetooth Bluetooth Status 5 Battery Power Indicator 6 Wavelength Wavelength 7 Unit Unit dB mW...

Page 13: ...13 44 OFIX Viewer PC 2 1 3 4 5 6 7 8...

Page 14: ...play Distance and Loss 2 Trace Trace Screen 3 Pointer To move left or right 4 Zoom Zoom In Out 5 A B Bar To set Start position and End position 6 Save Save as JPG BMP PNG PDF 7 Vertical Zoom To turn o...

Page 15: ...15 44 Num Function Description 1 Connect Choose Connect to OFIX 2 Measure ODTR Measure 3 Analyze Analyze to view saved SOR files 4 Config To View Settings 1 2 3 4 OFIX OTDR Mobile App Android...

Page 16: ...BLE devices around Choose your OFIX device Bluetooth name is on the back side of OFIX platform Num Function Description 1 Connect To enter Connect Menu 2 Find To display Bluetooth devices 3 Choose To...

Page 17: ...bar To choose distance or point we need 3 Zoom To Zoom in out or Reset Zoom 4 Measure Start To start Measure using OFIX 5 Clear To clear Screen 6 Info panel Display event information 7 Trace screen D...

Page 18: ...18 44 Num Function Description 1 Analyze To enter Analyze Menu 2 Open To choose automatically saved SOR file 3 Choose To open SOR file OFIX OTDR Mobile App Analyze 2 1 3...

Page 19: ...19 44 Num Function Description 1 Config To enter User Setting 2 User Config To view User Setting 3 Diagnostic To view H W S W version OFIX OTDR Mobile App Setting 1 2 3...

Page 20: ...han 5 Caution In case of low power OFIX will turn off automatically If it has not been used for an extended period of time after turned on OFIX to protect the internal battery connect the AC adapter P...

Page 21: ...r carefully to clean the contaminant 4 Repeat procedure 1 and 3 5 Prepare the optical port of OTDR module 6 Insect connector into optical port carefully Warning Caution 1 Insect connector carefully in...

Page 22: ...the tested fiber Optical attenuation coefficient of an optical fiber Single event loss such as the loss of a connection or a macro bending Or the loss of an end to end line on the tested optical fibe...

Page 23: ...a tested trace this may be caused by a connection point or some other reasons Anyway appearance of the reflection peak shows that the two connecting surfaces of the connection are smooth The smoother...

Page 24: ...e distance of the broken point of the initial connection is too close Curve with Non reflective Event There is a common phenomenon that an obvious step is on the middle of a tested trace it often caus...

Page 25: ...his phenomenon is often used in maintenance If a fiber is uncertain we can bend a fiber and make sure the bending radius is over limited then use real time testing function of the OTDR to confirm the...

Page 26: ...DR can generates a backward oblique trace which reflects several important attributes of an optical fiber When the light transmitting downward along the fiber meet a different density medium a part of...

Page 27: ...event usually it is an end face or a broken down point of a fiber Usually it is a Reflection event Reflection event The phenomenon on a trace that some power of the optical pulse is reflected called a...

Page 28: ...se width of transmit signal Average Number of average IOR Index of Reflection Setting Measurement Conditions Go to the Measure on the Main Screen of OFIX Mobile application Choose the parameter you ne...

Page 29: ...29 44 Setting to Auto Mode In Auto mode you could just proceed test by setting proper wavelength...

Page 30: ...30 44 Setting to Manual Mode In manual mode user could set proper range and pulse width manually...

Page 31: ...lication on your smartphone 2 Press Connect button on Main Screen of OFIX Mobile application 3 Choose the OFIX you want to connect 4 Press Measure button on Main Screen of OFIX Mobile application 5 Th...

Page 32: ...application on your smartphone 2 Press Measure button on Main Screen of OFIX Mobile application 3 Press Measure button 4 After Measurement was finished hold Blue bar and move it to the START point 5 T...

Page 33: ...33 44 File Operation OFIX Viewer 1 Connect your smartphone to PC 2 Open smartphone folder 3 Go to Phone GCIotdr Trace 1 sor 4 Choose the file you need 5 Click and open it...

Page 34: ...using OFIX Viewer 1 When you choose and opened SOR file you need 2 Hold and move A B bar to the point we want to measure 3 Above the graphic we can see the distance between A and B bar 4 Also we can s...

Page 35: ...button 3 Set Wavelength 4 Set Unit Optical Power Meter Module Optional OPM Module is used to quick get the power of terminal port at site REFRESH Refresh state of OFIX SELECT Switch Wavelength 850 13...

Page 36: ...36 44 Background Information on Measurements Viewing the Optical Pulse Measurement Waveform...

Page 37: ...to axis offset and angle offset Reflection due to connector connection Unlike the fused section a slight gap occurs in the connection section of connectors Because the group refraction index changes i...

Page 38: ...wer Replace a new battery 3 Install battery 4 Change another environment Battery doesn t work properly 1 Temperature is too high 2 Battery is nearly broken 1 Try to decrease temperature 2 Replace a ne...

Page 39: ...ata Storage Up to smartphone memory Interface TBD Working Temp 10 50 Storage Temp 20 70 Humidity 95 non condensation Dimension 188 L 102 W 37 D mm 0 55 kg battery included Accessories Main unit Power...

Page 40: ...00m 1 km 5km 10km 20km 30km 40km 50km Sampling resolution 2 5m Sampling point 12 000 point Linearity 0 05dB dB Scale indication X axis 4 70m div Y axis 0 09 5dB div Loss threshold 0 01dB Loss resoluti...

Page 41: ...41 44 Wavelength Range 1100 1620 nm Calibrated Wavelength 1300 1310 1490 1550 1625 1650nm Test Range 60 5 dBm Resolution 0 01dB Accuracy 0 35dB 1nW Modulation identification TBD OPM Module Optional...

Page 42: ...42 44 Dimension Unit mm...

Page 43: ...free of charge In no case will Company liabilities exceed the original purchase price of the product Warranty period is one year from the date of shipment to the original customer Exclusions The warr...

Page 44: ...CNU Cooperation Center for Industry W1 TEL 82 42 822 6781 FAX 82 42 822 6783 Web www gciinc co kr CEO ceo gciinc co kr Sales Department sales gciinc co kr Marketing Department marketing gciinc co kr G...