F4 PLUS

I-UK

SCHEMA ELETTRICO  / ELECTRICAL CONNECTIONS 

9

9

1

ON

ON

 M1

LAMP

LAMP

EARTH

230 V

ac ~ NEUTRAL

230 V

ac ~ PHASE

EARTH

FCC M2 (NC)

COM

FCA

 M2

 (NC)

FCC M1

 (NC)

FCA

 M1

 (NC)

PHOT

O

 (NC)

ST

ART

 (NO)

24V

ac

EL

 12V

ac

0V

ac

PED

 (NO)

ST

OP

 (NC)/SAF

.(8K2)

COM

COM

ANT

MOT

OR

OPEN

MOT

OR

CLOSE

MOT

OR

COM

 M2

MOT

OR

OPEN

MOT

OR

CLOSE

MOT

OR

COM

2

FORCE

M1-M2

RUN

TIME

P.S.

TIME

PAUSE

F1-5A

F2T

-160mA

RX

L1

230V

ac

40W MAX

LED

L1
L2
L3
L4
L5
L6

POWER

PED

START

PHOTO

STOP

FCA M1

L7
L8

FCC M1

FCA M2

L9

FCC M2

L10

SAFETY (8K2)

L11

-

POWER

DIP1

DIP2

M1

M2

M3

M4

L2 L3 L4 L5 L6

L7 L8

L9

L10

L11

Summary of Contents for F4 PLUS AS05850

Page 1: ...I UK Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CONNECTIONS F4 PLUS F4 PLUS AS05850 ...

Page 2: ... START NO 24Vac EL 12Vac 0Vac PED NO STOP NC SAF 8K2 COM COM ANT MOTOR OPEN MOTOR CLOSE MOTOR COM M2 MOTOR OPEN MOTOR CLOSE MOTOR COM 2 FORCE M1 M2 RUN TIME P S TIME PAUSE F1 5A F2T 160mA RX L1 230Vac 40W MAX LED L1 L2 L3 L4 L5 L6 POWER PED START PHOTO STOP FCA M1 L7 L8 FCC M1 FCA M2 L9 FCC M2 L10 SAFETY 8K2 L11 POWER DIP1 DIP2 M1 M2 M3 M4 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 ...

Page 3: ...230Vac PHASE NEUTRAL INTERRUTTORE DIFFERENZIALE RESIDUAL CURRENT DEVICE INTERRUTTORE MAGNETOTERMICO OVERCURRENT CIRCUIT BREAKER M2 M2 4 4 COLLEGAMENTO LAMPEGGIANTE FLASHING LIGHT CONNECTION LAMP LAMP 230 Vac 40W max M1 ON 9 OFF DIP1_9 ON on off on off M4 M1 230 Vac 40W max LAMP LAMP on off on off ON OFF DIP2_2 OFF DIP1_9 ON ...

Page 4: ... 2 Min 4 6 COLLEGAMENTO LUCE DI CORTESIA COURTESY LIGHT CONNECTION ON 9 OFF DIP1_9 OFF 4 LAMP LAMP M1 4 7 COLLEGAMENTO DISPOSITIVI DI COMANDO CONTROL DEVICES CONNECTION COM START NO PED NO M3 on off on off ON 2 OFF DIP2_2 ON 4 8 COLLEGAMENTO ELETTROSERRATURA ELECTRICAL LOCK CONNECTION M3 EL 12Vac 0Vac on off 2 Min ...

Page 5: ...S MANUAL FOR DETAILED CONNECTION DIAGRAMS COLLEGAMENTO FOTOCELLULE PHOTOCELLS CONNECTION 4 9 2 3 RX TX M1 1 2 3 4 M2 1 2 3 RX TX M1 1 2 3 4 M2 1 AU02000 SINCRONIZZATE SYNCHRONIZED PHOTO NC 24Vac 0Vac M3 PHOTO NC 24Vac 0Vac M3 8K2 4 11 COLLEGAMENTO DISPOSITIVO DI SICUREZZA 8K2 SAFETY DEVICE CONNECTION 8K2 8K2 M3 STOP NC SAF 8K2 COM ON 1 OFF DIP2_1 ON 4 31 COLLEGAMENTO STOP STOP CONNECTION 12 ON 1 O...

Page 6: ...BLED FCCM1ABILITATO FCCM1ENABLED FCCM1DISABILITATO FCCM1DISABLED FCCM2ABILITATO FCCM2ENABLED FCCM2DISABILITATO FCCM2DISABLED FCAM2ABILITATO FCAM2ENABLED FCAM2DISABILITATO FCAM2DISABLED INGRESSOPHOTODISABILITATO PHOTOINPUTDISABLED INGRESSOPHOTOABILITATO PHOTOINPUTENABLED MORSETTI7 8COMELUCEDICORTESIA TERMINALINPUTSN 7 8ASCOURTESYLIGHT MANTENIMENTOBLOCCOOLEODINAMICODISABILITATO HYDRAULICBLOCKMAINTEN...

Page 7: ...IME 2 SECONDS NOT ADJUSTABLE 31 TRIMMER PAUSE 18 PAUSE 3 SECONDS PAUSA 3 SECONDI PAUSE 103 SECONDS TEMPO PAUSA 103 SECONDI LEAF 1 SHIFT TIME CLOSING PHASE 20 SECONDS SFASAMENTO ANTA 1 IN CHIUSURA 20 SECONDI 31 TRIMMER RUN TIME 16 RUN TIME 103 SECONDS TEMPO DI LAVORO 103 SECONDI RUN TIME 2 SECONDS TEMPO DI LAVORO 2 SECONDI AUTOMATIC CLOSING DISABLED CHIUSURAAUTOMATICA DISABILITATA ...

Page 8: ...I DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC8786 05 2017 Rev 02 ...