background image

|  Care and Cautions  |  User Guide  |  

5

Overall Warnings

Damage  caused  by  misuse  may  void  the 

manufacturer’s warranty. Failure to comply with 

the following guidelines may result in injury or 

damage to the equipment. Additional warnings 

are found throughout the document.

GENERAL

This  simulator  is  constructed  of  material  that 

approximates skin texture. Therefore, in handling 

the model, use the same gentle techniques as 

you would in working with a patient.

Do not wrap this or any other Gaumard product 

in newsprint.

Indelible marks made with ballpoint pens, ink or 

marker cannot be removed. 

Do not use alcohol, acetone, Betadine® or any 

other antiseptic which contains iodine in this or 

any Gaumard® simulator. These products could 

damage or stain the skin of the simulator.

STORAGE

Improper  storage  may  damage  the  simulator.  

Keep it stored in the box and/or bag provided.

Store  the  simulator  in  a  cool,  dry  place.  

Extended  storage  should  be  between  32  -  85 

degrees  F  (0-29  Celsius).  Other  temperatures 

will  cause  the  simulator  to  soften  and  slowly 

warp.

Do not stack or store heavy materials on top 

of the box and/or bag.

It is acceptable to operate the simulator at an 

ambient temperature of 95 degrees Fahrenheit 

(35 Celsius).

CLEANING

Clean  the  skin  of  the  simulator  after  every 

training  session.  The  skin  should  be  cleaned 

with a cloth, dampened with diluted liquid dish 

washing soap.

Do not clean with harsh abrasives.

Dry thoroughly. 

The  simulator  is  “splash-proof”  but  not  water-

proof.  Do not submerge or allow water to enter 

the interior of the simulator.

Summary of Contents for S230.7

Page 1: ...tion Simulator S230 7 Gaumard Simulators for Health Care Education Advanced Patient Care Male Catheterization Simulator is an interactive educational system developed to assist a certified instructor...

Page 2: ...2 User Guide Obstetric Susie...

Page 3: ...5 General 5 Storage 5 Cleaning 5 Getting Started Overview 7 Appearance 7 Simulator 7 Other 7 Contents 7 Terminology 7 Equipment Set Up Filling the Sacs 9 Working with the Simulator Simulator Features...

Page 4: ...4 User Guide Care and Cautions Care and Cautions...

Page 5: ...his or any Gaumard simulator These products could damage or stain the skin of the simulator STORAGE Improper storage may damage the simulator Keep it stored in the box and or bag provided Store the si...

Page 6: ...6 User Guide Getting Started Getting Started...

Page 7: ...OR Full size adult lower torso with leg stumps OTHER One year limited warranty Contents Item Quantity Description 1 1 Real size lower human torso with male genitalia 2 1 Internal suprapubic bag 3 1 In...

Page 8: ...8 User Guide Equipment Set Up Equipment Set Up...

Page 9: ...imulator ensure the clamp is tightened 3 Insert the hose from the external bladder tank to the simulator s abdominal port 4 To fill the internal bladder tank raise the external bladder tank above the...

Page 10: ...10 User Guide Working with the Simulator Working with the Simulator...

Page 11: ...ter will lead to here 3 Please refer to Filling the Sacs in Chapter 3 Equipment Set Up to prepare the simulator for use 4 Apply lubricant to catheter 5 Continue procedure following aseptic technique A...

Page 12: ...er inflate as this may damage the airbag MALE CATHETERIZATION The urethra is connected to an internal urinary bladder Leakage is minimized through removable internal valves located between the urethra...

Page 13: ...Appendix User Guide 13 Appendix...

Page 14: ...le Any subsequent purchasers or users of the product acquire the product as is and this limited warranty does not apply This limited warranty applies only to the products manufactured and produced by...

Page 15: ...A Office hours Monday Friday 8 30am 4 30pm EST GMT 5 4 Summer Time General Information Gaumard ZOE Michelle Mike PEDI Susie Simon Susie Simon Code Blue SIMA Models SIMA GYN AID Virtual Instruments Cod...