background image

 

 

SMS format: 5550000 

Remarks: 0000 is the initial default password and the actual use s subject to the actual password. 

 

6. Regular Upload Interval Setup   

The defaulted factory upload interval of this device is 2 minutes for getting the point and 10 minutes for 

uploading  one  piece  of  positioning  information.  The  user  may  change  such  parameter  according  to  actual 

demand.   

Command format: # command number 730# Sampling interval # Pieces of uploads # User password ## 

For example: #730#20#4#0000## 

Note: The parameter “20” indicates getting one point every 20s; after getting points accumulatively for 4 

times, upload one piece of positioning information with the upload interval as 20*4=80s. The user may change 

this parameter as the case may be.     

 

7. Function of Changing Password 

Send  the  SMS 

“#770#  User  new  password  #  User  old  password  ##”

  by  mobile  phone  to  the  terminal 

number,  after  successful  sending,  the  mobile  phone  with  such  setup  will  receive  one  piece  of  config  ok 

response information, as shown in the following figure:   

 

Send command to the terminal    The terminal will return confirmation message to the mobile phone 

 

8. Low-Voltage Alarming Function 

If the terminal of the ward has a very low power and needs to be powered off, the terminal of the ward will 

automatically upload one piece of low-voltage alarming command to the monitoring center number.   

 

9. Set APN Command   

Create the SMS “802#APN letters or digits, 4-20 bits # Log user name letters or digits 4-20 bits in # 

Log password letter or digits 4-20 bits in # terminal password 4 bits ##” and send it to the terminal; after 

executing this command, the terminal will automatically restart and connect to 

GPRS with APN set. 

 

Command example 1: #802#cmnet###0000## 

Command example 2: #802#CCDLEN#QIUXIA.21#RX0000#0000## 

After  this  command  is  executed,  APN  will  be  CCDLEN;  the  login  user  name  is  QIUXIA.21  and  login 

password is RX0000.   

Note: The default APN of this product is CMNET.   

 

 

Summary of Contents for PT350

Page 1: ...racker User Manual Edition 1 0 Copyright Feb 15 2009 GATOR GROUP CO LTD All rights reserved LA Brand http www gatorcn com China Printing WEB http www gatorcn com EMAIL vip12 gatorcn com Tel 86 755 230...

Page 2: ...responding to and Operation Method of Basic Functions 5 1 Location Inquiry 5 1 SMS Inquiry 5 2 Setup of Center Number 6 3 Bi directional Call Function 6 5 Monitoring Function 6 6 Regular Upload Interv...

Page 3: ...ose for the actual product the latter will prevail 3 The defaulted password of this product is 0000 Chapter II About the Device PT350 as a personal remote positioning device made up of GPS module and...

Page 4: ...Technical Specifications GSM module GSM850 1900Hz or GSM900 1800MHz two combinations GPS chip Latest GPS sensitivity 159dBm GPS center frequency L1 1575 42MHz GPS positioning accuracy 5 25m GSM posit...

Page 5: ...USB charging cable For the first charge in order to bring the performance of the battery into full play charge it above 12h Indicator of charging Red being charged Green charging completed III Instal...

Page 6: ...function to be opened in real time Chapter IV Commands Corresponding to and Operation Method of Basic Functions 1 Location Inquiry 1 SMS Inquiry Create 666 password command defaulted password as 0000...

Page 7: ...After the setup is successful press the CALL 1 button then the terminal will automatically dia the first phone number Press the CALL 2 button then the terminal will automatically dial the second phon...

Page 8: ...umber after successful sending the mobile phone with such setup will receive one piece of config ok response information as shown in the following figure Send command to the terminal The terminal will...

Page 9: ...Example 801 13900139000 0000 Notes After executing this command the user name of the terminal on GPRS mode is required to be set up according to actual demand After the setup is successful the termina...

Page 10: ...messages to the user according to the alarming setup For example 740 0000 After the fence is set the terminal will alarm in the case where it is moved about 3 5km out of the fence 3 Fence Reading Fun...

Page 11: ...to the server as the configuration way Point to Point Function1 Single Position 666 Password The unit will send the latitude and longitude information to the sender after send 666 Password in 700 Mod...

Page 12: ...rd The parameter 20 indicates getting one point every 20s after getting points accumulatively for 4 times upload one piece of positioning information with the upload interval as 20 4 80s When you set...

Page 13: ...asic point 750 100 1 0000 2 751 500 5 2234 5848N 11354 028 0000 This command is mean that the unit will get the gps satellite and get the correct then the first position will be the basic point after...

Page 14: ...GPRS network 3 Make sure that the SIM card has sufficient balance in order to avoid inconvenience in use 4 This device will not be able to work in case of power off and out of the service area even if...