background image

PY800AC/PY1400AC SLIDING GATE OPERATOR

5

Fig.4

Fig.4

Fig.4

Fig.4

5.

5.

5.

5. Adjustment

Adjustment

Adjustment

Adjustment

Spring limit switch

To ensure safety, it is recommended to install limit switches at both

ends of the gate to prevent the gate from sliding out of the rails. The

rails must be installed horizontally.

Install the limit block as shown in Fig.5 and Fig.6. The spring limit

switch and blocks are used to control the position of the gate.

Release the gear with the key and push the sliding gate manually to

pre-determine the position, fix the block to the rack and lock the gear

by push up the release bar. Moving the gate electrically, adjust the

block to the proper position until the position of the opening and

closing meet the requirement.

Magnetic limit switch

To ensure safety, it is recommended to install limit switches at both

ends of the gate to prevent the gate from sliding out of the rails. The

rails must be installed horizontally.

Install the limit block as shown in Fig.4 and Fig.5. The magnetic of

limit switch and blocks are used to control the position of the gate.

 

Summary of Contents for PY1400AC

Page 1: ...Sliding Gate Operator User s Manual PY800AC PY1400AC PY800AC PY1400AC PY800AC PY1400AC PY800AC PY1400AC ...

Page 2: ... emergency emergency emergency purposes purposes purposes purposes 2 2 2 2 Important Important Important Important safety safety safety safety information information information information Carefully read and follow all safety precautions and warning before attempting to install and use this automatic gate operator Make Make Make Make sure sure sure sure the the the the Power Power Power Power su...

Page 3: ...00AC will handle gate weighting up to 800kg 1400 kg and up to 14m 20m if the proper installation procedures have been followed The PY800AC PY1400AC gate operator operates by forcing a drive rack by a drive gear The entire configuration is shown in the diagram below The gate operator must be installed on the inside of the gate Fig 1 Gate preparation Be sure the gate is properly installed and slides...

Page 4: ...to maintain proper stability The concrete pad should be approximately 450mm x 300mm x 200mm deep in order to providing for adequate weight and structure to insure proper stable installation Anchors see Fig 2 You can use anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator Gate operator Gear Groundsil...

Page 5: ...e package with rack on the rack element Lay the first piece of rack on the gear and weld the first nut on the gate Move the gate manually checking if the rack is resting on the gear and weld the second and third nut Bring another rack element near to the previous one Move the gate manually and weld the three nuts as the first rack thus proceeding until the gate is fully covered When the rack has b...

Page 6: ...gate Release the gear with the key and push the sliding gate manually to pre determine the position fix the block to the rack and lock the gear by push up the release bar Moving the gate electrically adjust the block to the proper position until the position of the opening and closing meet the requirement Magnetic limit switch To ensure safety it is recommended to install limit switches at both en...

Page 7: ...sh the sliding gate manually to pre determine the position fix the block to the rack and lock the gear by push up the release bar Moving the gate electrically adjust the block to the proper position until the position of the opening and closing meet the requirement Spring limit ...

Page 8: ...PY800AC PY1400AC SLIDING GATE OPERATOR 7 Gear Sliding gate Rack Limit block Magnetic Magnetic limit Fig 5 Spring limit Magnetic limit Fig 6 ...

Page 9: ...he supplied key in the lock Turn the key and pull down the release bar about 90 to release the gear Note Do not exceed 90 be careful not to use too much force otherwise the release bar will be damaged Open and close the gate manually Note If the gate bumps the mounting post and cannot be electric opened move the gate a few inches by hand thus you can release the gate with the key open and close th...

Page 10: ...tes notes notes of of of of control control control control board board board board a Power Input X1 E Earth L Live N Neutral PY800AC PY1400AC AC220V PY800ACU PY1400ACU AC110V b Caution light connect caution light wire toD1 and D2 terminal X3 PY800AC PY1400AC AC220V PY800ACU PY1400ACU AC110V c Output power supply 24VDC COM COM I R N C Infrared If the infrared beam is interrupted during closing the...

Page 11: ...ne lead of your keypad to CLS of terminal X4 and the other to the COM The keypad will function in single channel mode the DIP switch 1 should be turn to OFF For three button switch installation use the terminals for multi channel mode Connect open wire of external button switch to OPN of terminal X4 connect close wire of switch to CLS connect stop wire of switch to STP connect common wire of switc...

Page 12: ...ote control The remote control works in a single channel mode It has four buttons See Fig 12 Remote transmitter only one type The function of button 1 button 2 button3 and button 4 are the same With each press of the remote control button which has been programmed the gate will close stop open or stop cycle You can program learn button 1 button 2 and button 3 individually You also can program lear...

Page 13: ... turns off This indicates that all the remote controls have been erased completely Note Note Note Note Press the OPEN button of external button switch or remote control button which has been learned the gate will open the motor rotates clockwise and the LED2 is turns on The output voltage between D1 and D2 terminal X3 is AC220V 110V the voltage between V and U is AC220V 110V Press STOP button or t...

Page 14: ...ice device device device responds responds responds responds to to to to your your your your requested requested requested requested function function function function correctly correctly correctly correctly you you you you have have have have set set set set the the the the function function function function successfully successfully successfully successfully otherwise otherwise otherwise other...

Page 15: ...ocell photocell photocell If infrared beam is interrupted during closing the gate will reverse and go open immediately This feature will not function if the gate is in fully opened and closed positions or during opening Open Open Open Open priority priority priority priority The gate will return to open if press OPEN button of external button switch during closing Limit Limit Limit Limit switch sw...

Page 16: ...pen fails to close 1 Infrared beam is obstructed 2 Infrared photocell function is enable but the photocell has not been installed 1 Remove obstructions 2 Make sure the infrared photocell function is disable Remote transmitter does not work 1 Battery level may be low 2 Transmitter code is lost 1 Replace the battery inside the transmitter 2 Re program the transmitter The transmitter operating distan...

Page 17: ...PY800AC PY1400AC SLIDING GATE OPERATOR 16 No Item Quantity 1 PY800AC PY1400AC sliding gate operator 1 2 Transmitter 2 3 Release key 2 4 User s manual 1 ...

Page 18: ...UTLINE 1 Products introduction 1 2 Important safety precautions 1 3 Main technical parameters 1 4 Mechanical Installation 2 5 Adjustment 5 6 Wire Connecting 9 7 Turning and operation 11 8 Programming Process 13 9 Maintenance 15 10 Trouble Shooting 15 11 Packing list 16 ...

Reviews: