Installing an Intel Management Module (IMM)
7
Find the IMM connector on the right side of the system board.
8
Grasp the module board by one edge and the plastic handling strap (close to the
mounting connector), align the board with the IMM connector on the system board,
then gently apply pressure to seat the module.
Make sure the module is fully seated and the nylon standoffs are inserted into the
corresponding holes in the system board.
9
Replace the memory boards or memory board air baffles into memory slots C and D
by following the instructions in
“Installing and removing memory boards” on
.
10
Replace the processor air baffle by following the instructions in
installing the processor air baffle” on page 67
11
Follow the instructions in
“Closing the server case” on page 72
12
Follow the instructions in
“Updating the BMC firmware” on page 47
Following the installation of a new Intel Management Module, you must reinstall the
GSM software (from a CD which accompanied your server) and update the FRU/SDR
(see
“FRU/SDR Load utility” on page 54
). When you subsequently reboot your server,
the GSM software will take over management of the server.
For information on the Embedded Web Server, see
.