GatesAir
B-1
Intraplex Products
Appendix B – Data Rate Selection Table
Table B-1 gives a complete listing of all available data rates for a DS-64NC module, with the settings
for S4, positions 1-10 to select these rates. For each switch position, 0 = UP, 1 = DOWN. The table
also lists the number of 64 kbps time slots occupied by a data signal at each rate, when the module is
set up to use either 64 or 56 kbps per time slot.
Table B-1. DS-64NC Module Data Rate Selection
Data
Rate
(kbps)
S4, Positions 1-10 Settings:
0 = UP, 1 = DOWN
Number of Time Slots Occupied
at This Rate
1
2
3
4
5
6
7
8
9
10
64 kbps/Slot
56 kbps/Slot
8
0
0
0
0
0
0
0
1
0
0
1
1
16
0
0
0
0
0
0
1
0
0
0
1
1
24
0
0
0
0
0
0
1
1
0
0
1
1
32
0
0
0
0
0
1
0
0
0
0
1
1
40
0
0
0
0
0
1
0
1
0
0
1
1
48
0
0
0
0
0
1
1
0
0
0
1
1
56
0
0
0
0
0
1
1
1
0
0
1
1
64
0
0
0
0
1
0
0
0
0
0
1
2
72
0
0
0
0
1
0
0
1
0
0
2
2
80
0
0
0
0
1
0
1
0
0
0
2
2
88
0
0
0
0
1
0
1
1
0
0
2
2
96
0
0
0
0
1
1
0
0
0
0
2
2
104
0
0
0
0
1
1
0
1
0
0
2
2
112
0
0
0
0
1
1
1
0
0
0
2
2
120
0
0
0
0
1
1
1
1
0
0
2
3
128
0
0
0
1
0
0
0
0
0
0
2
3
136
0
0
0
1
0
0
0
1
0
0
3
3
144
0
0
0
1
0
0
1
0
0
0
3
3
112
0
0
0
0
1
1
1
0
0
0
2
2
120
0
0
0
0
1
1
1
1
0
0
2
3
128
0
0
0
1
0
0
0
0
0
0
2
3
136
0
0
0
1
0
0
0
1
0
0
3
3
144
0
0
0
1
0
0
1
0
0
0
3
3
152
0
0
0
1
0
0
1
1
0
0
3
3
160
0
0
0
1
0
1
0
0
0
0
3
3
168
0
0
0
1
0
1
0
1
0
0
3
3
176
0
0
0
1
0
1
1
0
0
0
3
4
184
0
0
0
1
0
1
1
1
0
0
3
4
192
0
0
0
1
1
0
0
0
0
0
3
4
200
0
0
0
1
1
0
0
1
0
0
4
4
208
0
0
0
1
1
0
1
0
0
0
4
4
Summary of Contents for Intraplex DS-64NC
Page 2: ......
Page 8: ...No header here iv GatesAir Intraplex Products This page is left blank intentionally...
Page 10: ......
Page 11: ...1 2 GatesAir Intraplex Products This page is left blank intentionally...
Page 12: ......
Page 32: ......
Page 33: ...2 20 GatesAir Intraplex Products This page is left blank intentionally...
Page 34: ......