GATEMASTER 900 HD Installation Manual Download Page 2

        Swing Gate Opener Manual 

 

Warnings 

 

Please read this instruction manual carefully before the installation of gate operator system. 

 

A wired photo eye sensor must be installed for this gate operator to function properly 

(UL325-2016) 

 

This manual is exclusively for qualified installation personnel. We are not responsible for 

improper installation and failure to comply with local electrical and building regulations. 

 

* Be aware of the hazards that may exist in the procedures of installation and operation of 

the gate-automated system. Besides, the installation must be carried out in conformity with 

local standards and regulations. 

 

* If the system is correctly installed and used following all the standards and regulations, it 

will ensure a high degree of safety. 

 

* Make sure that the gates work properly before installing the gate-automated system and 

confirm the gates are appropriate for the application. 

 

* Do not let children operate or play with the gate-automated system. 

 

* Do not cross the path of the gate-automated system when operating  

 

* Please keep all the control devices and any other pulse generator away from children to 

avoid the gate-automated system being activated accidentally. 

 

* Do not make any modifications to any components that is not in this manual. 

 

* Do not try to manually open or close the gate before you release the gear motor. 

 

* If there is a failure that cannot be solved and is not mentioned in this manual, please 

contact qualified installation personnel. 

 

* Do not use the gate-automated system before all the procedures and instructions have been 

carried out and thoroughly read. 

 

* Test the gate-automated system weekly and have qualified installation personnel to check 

and maintain the system at least every 6 months. 

 

* Install warning signs on the both sides of the gate to warn the people in the area of 

potential hazards. 

 

Technical Characteristics 

Motor: 24VDC motor with mechanical release 

Gear type: Worm gear 

Max absorbed power: 144W 

Peak thrust: 3500N 

Nominal thrust: 3000N 

Stroke length: 300mm 

 

 

Power supply: 110VAC converted to 24VDC with 

built in transformer 

Nominal input power: 2A 

Maximum operating current: 5.5A for maximum 10 

seconds 

Maximum gate weight: 500 lbs. per leaf 

Maximum gate length: 14 ft. 

Duty cycle: 20% 

 

Summary of Contents for 900 HD

Page 1: ...GATEMASTER 900 HD Installation Manual...

Page 2: ...tem when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated accidentally Do not make any modifications to...

Page 3: ...cluded and must be purchased separately Description of the Automation The following diagram of typical installation describes some terms and accessories of a gate automation system Motors Components I...

Page 4: ...ot meet the requirements Make sure the gate structure conforms to the criteria of automatic operation and force regulations Make sure there is no serious friction existing in the opening or closing tr...

Page 5: ...If the gate is OPENED OUTWARD please leave at least 70 mm 3 inches between the post brackets and the gate Using the leaf opening angle as criteria to make sure all criteria in Figure 17 can be met...

Page 6: ...oth vertical and rigid Arrange the cable conduit for power supply cable of the motors Loosen the two screws and remove the back cover of the motor as shown in photo Place the gate leaves in the closed...

Page 7: ...gure 22 Refer to Figure 23 the distance between gate attach bracket mounting hole of the motor and post bracket mounting hole is 796mm 31 the gate attach Figure 23 Now the post bracket is securely fas...

Page 8: ...plate on the release part to OPEN position See Figure 29 Push out the release part to the end See Figure 30 Use the release key to turn the pin ani clockwise to the end See Figure 31 Figure 29 Figure...

Page 9: ...or and mount the control box using such fasteners as you see fit Also mount a watertight junction box underneath the control box for 110vac Single gate installation Run the two pair wire from the actu...

Page 10: ...sor 5 COM terminal is COMMON used for connecting the ground of external devices 6 Infrared terminal is used for connecting photo eye sensor 7 12V DC output is used for connecting photo eye sensor Cont...

Page 11: ...utton for about 5 second if with one buzzer sound and indicator LED light on then now means remove remote successfully Setting of the control board After power on digital display will self check from...

Page 12: ...g time setting There is 0 33s for optional 0s means without high speed running gate opener would keep running in slow speed Max high speed running time 33s Each time you press and release the INC butt...

Page 13: ...rm output control setting finished factory set 0 8 To set lock time When digital display indicates Pb the gate opener is on lock time control setting The lock control time means the time we could cont...

Reviews: