background image

17 

 

DIP Switch #5:  Direction of gate opening.* 

(* 

Direction from the inside of the property where the opener is installed.)

 

 

 

DIP Switch #5:      OFF

 – Opens to the right.

 

 

 

 

 

 

 

DIP Switch #5:      ON – 

Opens to the left.

 

 

 

Note:  If opening is to the left, the Limit Switch wires on the control board (yellow & red) need to 
be reversed. The black wire stays the same. 

Summary of Contents for GA2000

Page 1: ...1 Sliding Gate Opener User s Manual Gat Model GA2000 Gate1Access LLC www gate1access com Email support gate1access com...

Page 2: ...might occur during use Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted Check that a differential switch with a 0...

Page 3: ...2pcs L Chain Bracket 2pcs M10 45Hex bolt 4PCS 10 Plain Washer 4pcs 10Sprin Washer 4pcs Chain Box 1pc M6X30 Stainless Steel AllenScrew 4pcs M12 Chain Bolt 2pc M12 Hex Nut 4Pcs 12 Spring Washer 4pcs 12...

Page 4: ...5cmX49 6cm L W H Features Easy to install and low maintenance Quick selection for gate open close direction Get the desired chain tension by adjusting the chain bolts Homelink compatible technology E...

Page 5: ...ns 9 10 Manual Operation 10 Installation of chain and chain brackets 11 13 Limit Switch Settings 14 Control Board 15 20 Wiring Instructions 15 Setting the DIP Switches 16 17 Direction of gate opening...

Page 6: ...e MUST reverse on contact with a rigid object or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate opener Failure to adjust and ret...

Page 7: ...ly installed and work freely in both directions prior to the installation of the gate opener Do not over tighten the opener clutch or pressure relief valve to compensate for a damaged gate E For gate...

Page 8: ...of a vehicular vertical lift gate 3 One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate 4 A hardwired contact sensor shall be located and its wiring arra...

Page 9: ...ult in property damage severe injury and or death Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailment Ens...

Page 10: ...te frame with the chain bolts Bolts and brackets supplied in package 5 Mount the chain box to the base plate by using screws and washers don t make the four screws too tight 6 Move the opener to the p...

Page 11: ...chain brackets figure which shows U bolt L bracket and chain bolt Use the U bolts square or round to attach the chain brackets to gate frame b If both the square bolts and round bolts are not fit for...

Page 12: ...ther master link 3 Connect the remaining 10ft chain provided to the left end of the chain coming out of the chain box using a master link a Measure the length of chain needed to get to the chain bolt...

Page 13: ...ckets 1 The chain brackets must be mounted to the same height as the chain on the guiding sprockets 2 The opener must be parallel to the gate 3 Make sure there is 1 distance at least between the chain...

Page 14: ...setting the open limit After adjusting the opener with chain and fixing the opener to the ground check if the gate is still in close position then moving the gate to the fully open position and start...

Page 15: ...Also the and terminals of the photocell s receiver should be connected to the 11 and 12 terminals in parallel Use another 2 core cable to connect the NO terminal of the receiver to the 21 terminal the...

Page 16: ...IP Switch 1 Limit switch NC normally closed or NO normally open DIP Switch 1 ON NO OFF NC This mode enables user to set the board to work with motor with NC or NO limit switch NOTE Factory default set...

Page 17: ...inside of the property where the opener is installed DIP Switch 5 OFF Opens to the right DIP Switch 5 ON Opens to the left Note If opening is to the left the Limit Switch wires on the control board y...

Page 18: ...8 ON Blue Button is Working OFF Blue Button is Not Working 2 Potentiometers The left potentiometer is to adjust the CLOSE stall force of the gate opener The right Potentiometer is used to adjust the...

Page 19: ...meter in counter clockwise direction Turning the stall force potentiometer toward to Light position to increase the reversing sensitivity Note 1 If the sensitivity setting is too higher the gate will...

Page 20: ...20 Control Board Wiring Diagram...

Page 21: ...control does not work a The distance you use the remote is too far away from the opener Try it again closer b Remote control is not suitable for receiver After making sure the codes are correct erase...

Page 22: ...sn t move a The clutch for emergency release is adjusted properly and is not slipping Maintenance Every six months check the following items for proper operation of the unit Lubricate shafts and sproc...

Reviews: