background image

GM720A-YF A

/C Service Station

6

process. Please do not stop it. The used oil can be drained out automatically.

Warning: Strictly prohibit to press the Button switch of new & used oil bottles.

6) Recovery/Recycling

A

By this function, it will recover the refrigerant remained in the A/C system.

B

Operations:

B-1: Select the Recovery Function

and press the ENTER key.

B-2: Press the ENTER key to start.
B-3: After recovery over, it’ll drain the used oil automatically.

C

When finished, it’ll stop automatically.

Notice: After end, you can drain the used oil by manual.

7) Vacuum

A

By this function, it will clean the water vapor out from the A/C system.

B

It should be more than 15 minutes. Generally, it needs 15 minutes at least for the air conditioning only
with front wind and 20 minutes for with the front and rear wind.

C

Operations:

C-1: Select the Vacuum Function

and press the ENTER key.

C-2: Set the vacuum time.
C-3: Press the ENTER key to start.

D

When finished, it’ll stop automatically.

8) New oil adding

A

It must be able to do after vacuum process.

Warning: please do not press the switch of the new oil bottle anytime when the automotive air
conditioning system is not in vacuum state, otherwise it have the risk of explosive bottles!

B

Pour new oil into the new oil bottle.

Note: add new oil more 20ml than the used oil drained out to avoid the air into the air conditioning
system.

C

Method 1: Control by manual.

After vacuum, press the button switch of the new oil bottle to fill the new oil.

D

Method2

Control automatically.

D-1:

Select the New oi adding Function

and press the ENTER key.

Summary of Contents for GM720A-YF

Page 1: ...GM720A YF A C Service Station GM720A YF A C System Maintenance Centre...

Page 2: ...such as cooling fans alternators and heating components etc to avoid harm F Wear protective clothing gloves and goggles G As automotive air conditioning pipe flushing the operator must be fully famili...

Page 3: ...ew oil adding 6 9 Recharging 7 10 Auto Mode 7 11 Database 8 12 Equipment Maintanance 8 12 1 Exchange dry filter 8 12 2 Clean pipe of the unit 8 12 3 Calibration of load cell 8 12 4 Change vacuum pump...

Page 4: ...prove the cleaning effect D Using large size glass tube with LED backlighting can effectively observe the entire cleaning process E Vertically installing the HP LP gauges let the operator be able to o...

Page 5: ...unctions A Automatic flushing B Automatic recovering recycling C Automatic manual used oil drain D Vacuum timing E Automatic manual new oil injection F Quantitative recharging G Auto mode H Database I...

Page 6: ...rts descriptions HP gauge Operation panel LP gauge Dry filter service port TP gauge Switch for new oil adding New oil bottle Switch for used oil discharge Used oil bottle Printer LCD display HP Port L...

Page 7: ...lease refer to the chapter of Refrigerant supply D Please read this user manual carefully before operating 3 Preparations before Operation A To check if there has enough refrigerant in the tank The vo...

Page 8: ...irely to improve the performance of compressor And also it will recover the refrigerant remained in the A C system B Before flushing the pipeline of automotive A C system please turn on A C system and...

Page 9: ...eds 15 minutes at least for the air conditioning only with front wind and 20 minutes for with the front and rear wind C Operations C 1 Select the Vacuum Function and press the ENTER key C 2 Set the va...

Page 10: ...ng Note In the recharging process if shows the menu it means that you need to turn on the car air conditioning to complete the recharging process Later you should supply new refrigerant into the tank...

Page 11: ...er 12 2 Clean pipe of the unit A After a period of use such as 2months it should be run this function B It can clean up the pipe line of the machine 12 3 Calibration of load cell A When the load cell...

Page 12: ...the High pressure Alarm it need do this function B We advise that it should be done once a month 14 System function 14 1 Supply main tank internal tank A If the refrigerant amount in the main tank is...

Page 13: ...tank upside down M2 2 Connect the HP or LP coupler to the supplying connecter M2 3 Select the Recovery function and run it M2 4 When you see the total amount more than 4 5kg close the valve of the re...

Page 14: ...machine 15 2 Servicer info Here you can set and check the servicer and dealer information The way for setting Press and keys at same time into the setup state Use the and keys to select position Use...

Page 15: ...GM720A YF A C Service Station 12 16 Help Here you can check all of the help messages...

Page 16: ...GM720A YF A C Service Station 13 Declare We reserve the right to modify the contents of this document without prior notice to our customers...

Reviews: