TROUBLE SHOOTING GUIDE
REASON
LOW
PRESSURE
HIGH
PRESSURE
LOW
VACUUM
EXCESSIVE
NOISE
OVER
HEATING
WON'T
START
Dirty Filter
x
x
Dirty Muffler
x
x
x
Dirty Valves
x
x
Damaged Valves
x
x
x
x
Worn/Damaged Cup
x
x
Improper Cylinder
Shimming
x
x
x
x
x
x
Leaky Hose
x
x
Leaky Check Valve
x
Plugged Vac. or
Press. Line
x
x
x
x
x
Low Voltage
x
x
x
x
Leaky Relief Valve
x
x