Gast ROA Series Operation & Maintenance Manual Download Page 8

 

TROUBLE SHOOTING GUIDE

REASON

LOW

PRESSURE

HIGH

PRESSURE

LOW

VACUUM

EXCESSIVE

NOISE

OVER

HEATING  

WON'T

START

Dirty Filter

x

x

Dirty Muffler

x

x

x

Dirty Valves

x

x

Damaged Valves

x

x

x

x

Worn/Damaged Cup

x

x

Improper Cylinder
Shimming

x

x

x

x

x

x

Leaky Hose

x

x

Leaky Check Valve

x

Plugged  Vac. or
Press. Line

x

x

x

x

x

Low Voltage

x

x

x

x

Leaky Relief Valve

x

x

We have Gast Authorized Repair Facilities throughout the world.   For the most up-to-date listing,
contact one of our sales offices below:

European Sales & Service Headquarters
Beech House Knaves Beech Business Centre
Loudwater, High Wycombe Bucks, England HP10 9SD
Tel:   +44  1628 551500
Fax:  +44  1628 551590
www.gastmfg.com

Gast Hong Kong
Unit 12, 21/F, Block B
New Trade Plaza
6, On Ping Street, Shatin
N. T. Hong Kong
Ph:  (852) 2690 1008
Fax: (852) 2690 1012
www.gasthk.com

World Headquarters
P.O. Box 97
2550 Meadowbrook Rd.
Benton Harbor, MI 49023-0097
Ph: 269/926-6171
FAX: 269/925-8288
www.gastmfg.com

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2003 Gast Manufacturing Inc. All Rights Reserved.

Summary of Contents for ROA Series

Page 1: ...rosive gases and particulate material will damage unit Water vapor oil based contaminants or other liquids must be filtered out Consult your Gast Distributor Representative before using at high altitudes This pump is oil less and requires NO lubrication ROA RAA ROCKING PISTON OIL LESS PUMPS Operation Maintenance Manual WARNING PLEASE READ THIS MANUAL COMPLETELY BEFORE USING THIS PRODUCT SAVE THIS ...

Page 2: ...ced voltage conditions The wiring diagram supplied with the product provides required electrical information Check that power source is correct to properly operate the dual voltage motors Electrical Connection c Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other liquids Install t...

Page 3: ... cord is in good condition Check that the gage wire of the extension cord is the correct size wire to carry the current this product will draw An undersized cord is a potential fire hazard and will cause a drop in line voltage resulting in loss of power causing the product to overheat The following table indicates the correct size cord for length required and the ampere rating listed on the produc...

Page 4: ...ting periods 1 Disconnect plumbing 2 Operate product for at least 5 minutes without plumbing 3 Run at maximum vacuum for 10 to 15 minutes 4 Repeat step 2 5 Disconnect power supply 6 Plug open ports to prevent dirt or other contaminants from entering product SERVICE KIT INSTALLATION Gast will NOT guarantee field rebuilt product performance For performance guarantee the product must be returned to a...

Page 5: ... THE PURCHASE PRICE IN LIEU OF REPAIR OR REPLACEMENT GAST WILL NOT BE RESPONSIBLE OR LIABLE FOR INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND however arising including but not limited to those for use of any products loss of time inconvenience lost profit labor charges or other incidental or consequential damages with respect to persons business or property whether as a result of breach of warrant...

Page 6: ... Ring Cylinder 1 AH179 AH179 AH179 AH179 AH179 8 Cylinder 1 AJ342 AJ342 AJ342 AJ342 AJ342 9 Shims As AJ345 AJ345 AJ345 AJ345 AJ345 Req 10 Cup 1 AH175 AH175 AH175 AH175 AH175 11 Retainer Plate 1 AT715A AT715A AT715B AT715B AT715A 12 Connecting Rod 1 AT846 AT846A AT846N AT846G AT846G Assy 13 Fan 1 AF533 AF533 AF533 AF533 AF533 14 Grille 1 AH185 AH185 AH185 AH185 AH185 15 Screw 2 AT283 AT283 AT283 AT...

Page 7: ... AH817 7 O Ring Cylinder 2 AH179 AH179 AH179 8 Cylinder 2 AJ342 AJ342 AJ342 9 Shims As AJ345 AJ345 AJ345 Req 10 Cup 2 AH175 AH175 AH175 11 Retainer Plate 2 AT715B AT715B AT715A 12 Connecting Rod 2 AT846H AT846J AT846L Assy 13 Fan 1 AF533 AF533 AF533 13A Fan 1 AF533A AF533A AF533A 14 Grille 2 AH185 AH185 AH185 15 Screw 4 AT283 AT283 AT283 Service Kit 1 K756 K757 K756 K756 K757 Denotes parts include...

Page 8: ... listing contact one of our sales offices below European Sales Service Headquarters Beech House Knaves Beech Business Centre Loudwater High Wycombe Bucks England HP10 9SD Tel 44 1628 551500 Fax 44 1628 551590 www gastmfg com Gast Hong Kong Unit 12 21 F Block B New Trade Plaza 6 On Ping Street Shatin N T Hong Kong Ph 852 2690 1008 Fax 852 2690 1012 www gasthk com World Headquarters P O Box 97 2550 ...

Reviews: