Gasmate SOLARIS Series Operation, Installation, And Maintenance Manual Download Page 2

Table of Contents

Important Safety Rules

1

Product Overview 

2-3

Installation Servicing

4-6

Operation Instructions

7-11

RH200 Auto Electrical Diagram

12

RH200 Automatic Ignition Overview

13-14

Safe Appliance Locations

15

Troubleshooting

16

Spare Parts

17-18

2

Installation, Operation and Maintenance Instructions

1.  This appliance shall not be installed or used  

indoors, in buildings, garages or any other 
enclosed area.

2. 

DO NOT

 place articles on or against this 

appliance.

3. 

DO NOT

 use or store flammable materials near 

this appliance. 

4.  Children and adults should be alerted to the 

hazards of high surface temperatures, burns 
and clothing ignition.

5.  Children should be carefully supervised when 

they are in the area of the appliance.

6. 

NEVER

 hang anything including clothes or 

other flammable items on the appliance.

7.  

DO NOT

 operate this appliance unless it is 

fully assembled with burner guard in place.

8.  

DO NOT SPRAY AEROSOLS IN THE 
VICINITY OF THIS APPLIANCE WHILE IT IS 
IN OPERATION.

9.  Installation and repair should be done by a 

qualified service person. The appliance must 
be inspected before use and at least annually 
by a qualified service person.  It is imperative 
that control compartment, burners and 
circulating air passages of the heater be kept 
clean.

10.  This appliance must be only used in a well 

ventilated area. 

11.  Do not perform maintenance until heater has 

been turned off, and heater has cooled to 
room temperature.

12.  Do not expose the burner to water or moisture. 

The appliance must be protected from rain and 
wind.

13.  Avoid inhaling fumes emitted from the heater’s 

first use. Smoke and odour from the burning 
of oils used in manufacturing will appear. 
Both the smoke and odour will dissipate after 
approximately 20-30 minutes.

14.  Any modification to the heater not described in 

the installation instructions may compromise 
the safety of this appliance. Special concern is 
as follows:

(1) DO NOT bypass thermocouple safety burner;
(2) DO NOT operate appliance without the guard;
15.  Clothing or other flammable materials should 

not be hung from the appliance, or placed 
on or near the appliance. The area above the 
burner may be extremely hot. Direct contact 
with these metal surfaces should be avoided in 
order to prevent burns or clothing ignition.

16.  The appliance must be used or installed in a 

location such that it is  readily accessible for 
servicing and have no restriction of air flow to 
the air inlet of the heater’s casing.

17.  Special conditions that must be avoided, 

e.g. marine environment and any conditions 
necessary to ensure optimum performance.

IMPORTANT SAFETY RULES

 

Summary of Contents for SOLARIS Series

Page 1: ...tore or use gasoline or other flammable vapour and liquids in the vicinity of this or any other appliance DANGER Improper installation adjustment alteration service or maintenance can cause injury or...

Page 2: ...ent burners and circulating air passages of the heater be kept clean 10 This appliance must be only used in a well ventilated area 11 Do not perform maintenance until heater has been turned off and he...

Page 3: ...follows Minimum Clearance from Combustibles Side 1000 mm Bottom 2000 mm Ceiling 400 mm Combustible materials are considered to be wood compressed paper plant fibres plastic plexiglas or other materia...

Page 4: ...erformed with soapy water whenever connecting a new cylinder NEVER use a match to test for leaks 3 The propane cylinder must be turned off whenever the appliance is not in use When the appliance is to...

Page 5: ...signed for relocation to varying locations so the most preferable permanent location should be selected prior to installation TO BE INSTALLED ONLY BY AN AUTHORISED PERSON HEATER ASSEMBLY NOTE Recommen...

Page 6: ...ombustible materials In open locations subject to rain In indoor residential locations In areas without sufficient clearances refer below INSTALLATION AND SERVICING IMPORTANT This appliance must only...

Page 7: ...ge 3 4 Turn on the gas supply either at the mains or gas cylinder 5 Apply the soapy water solution to the 3 connections 6 If soap bubbles appear at any of the connections there is a gas leak 7 If a ga...

Page 8: ...ing Gas Requirements 4 Turn the power on at the power point 5 Automatic Ignition Once the power is turned on and gas is flowing to the unit it should automatically begin to ignite the heater Visually...

Page 9: ...ed to a ball valve socket containing an on off tap then simply turn the gas off at the tap If the heater is connected to a bayonet point then the hose will need to be disconnected from the bayonet soc...

Page 10: ...nstruction manual under the heading Gas Requirements 4 Igniting the unit Pull and hold down the ignition cord on right and maintain tension for approx 10 seconds to ignite the tiles Maintain the hold...

Page 11: ...e disconnected from the bayonet socket to shut the gas off Note The heater must be completely shut off for 10 minutes before being relighted This allows for any excess gas to dissipate and for the uni...

Page 12: ...ELECTRICAL DIAGRAM NOTE THIS DIAGRAM IS SPECIFICALLY FOR THE RH200 AND IS NOT APPLICABLE FOR THE RH205 RH200 SOLARIS DELUXE AUTO ELECTRICAL DIAGRAM WIRING DIAGRAM HONEYWELL CONTROL HONEYWELL GAS VALV...

Page 13: ...lished flame signal is lost during the safety time or during operation thereafter this will cause the ignition device to be reactivated within 1 second If the burner does not light within 25 seconds o...

Page 14: ...or cover outlet and inlet back on RH200 SOLARIS DELUXE AUTO ELECTRICAL DIAGRAM OPERATION DATA HONEYWELL VALVE The VK series gas control have been specially developed for application in domestic applia...

Page 15: ...which the appliance is used shall comply with the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover see Example 1 Within a partia...

Page 16: ...t out a RH205 Only Faulty thermocouple Replace tighten thermocouple Contact Licenced Gas Installer b Poor gas supply Trace back to source clear where necessary Contact Licenced Gas Installer c Faulty...

Page 17: ...wing parts must be installed by a licenced installer Failure to follow this direction can be dangerous and will void the warranty DESCRIPTION PART Ceramic Tile Assembly 91 RH200CTA Ion Sensor 91 RH200...

Page 18: ...st be installed by a licenced installer Failure to follow this direction can be dangerous and will void the warranty DESCRIPTION PART Ceramic Tile Assembly 91 RH200CTA Natural Gas Injector 91 RH200INJ...

Page 19: ...19 NOTES...

Page 20: ...e call Customer Service Australia Only 1300 174 876 Hours of operation Monday to Friday 8am 5pm EST Do not return to place of purchase Keep your purchase receipt this will be required to make any clai...