WARNING

• Improper installation, adjustment, alteration, service or maintenance can cause injury  

or property damage.

• Read the instructions thoroughly before installing or servicing this equipment.
• THIS APPLIANCE MUST NOT BE INSTALLED OR USED INDOORS.
• NATURAL GAS APPLIANCE. TO BE INSTALLED ONLY BY AN AUTHORISED PERSON.
• THE AUTHORISED PERSON WILL PROVIDE A CERTIFICATE OF COMPLIANCE.
• A Gasmate NGC30 or NGC40 AGA approved natural gas pressure regulator must be installed in the pipeline and 

be set at 1 kPa.

NATURAL GAS CONVERSION

TO BE INSTALLED ONLY ON OR IN A NON-
COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.

Tools Required: 
Screw driver, adjustable spanner, Phillips head screw 
driver.

GAS PIPING 

1.   This appliance is only to be installed by an authorised 

person.

2.   Check with local and state plumbing and heating 

codes regarding sizing of the gas lines.

3.   All gas pipe connections must be sealed with a gas 

pipe compound resistant to Natural Gas.

4.   Installation of a drip leg if required in the gas supply 

line must conform to AS5601.

5.   When checking for gas leaks, do not use an open 

flame.  Use a soap and water solution and check for 
bubbles indicating gas leakage.

6.   Installation of 1/8” NPT plugged tapping, accessible 

for test gauge connections, is required upstream of 
the gas supply connection.

Warning 
Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. Read 
the instructions thoroughly before installing or servicing 
this equipment.

SERVICING INSTRUCTIONS
Appliances should be serviced at least annually and 
servicing must only be carried out by a Licensed Plumber 
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush. 
Inspect and clean all combustion air inlets, then replace 
the Burner ensuring it is firmly secured.

Minimum Clearance for Ventilation:
Rear - 50mm         Side - 50mm

NOTE TO THE INSTALLER:
The injector size is increased by removing the Propane 
Nozzle (outer brass cap) and leaving the Natural Gas 
Nozzle in place.  Ensure the Natural gas nozzle is still 
tight and in the correct position and the hole size is 
correct.  
To adjust the turndown/low remove the control knobs 
to allow access to the “LOW” adjustment screw. With a 
small blade screwdriver turn the brass screw fully anti-
clockwise.

TEST OPERATION OF APPLIANCE  
BEFORE LEAVING.

Conversion ONLY to be done by an authorised person.

Overall Dimensions

Length

Width

Height

BQ1096SL

933mm

609mm

255mm

Summary of Contents for SOHO

Page 1: ...MJ h Supplied fully assembled Complete with hose and regulator Operates on Propane or ULPG Gas Certified to Australian Standards Suitable for Natural Gas conversion Important Retain these instructions...

Page 2: ...th the hose and regulator supplied Your barbecue is designed for use with 9Kg propane gas cylinders certified to AS 2469 The cylinder should be filled by a reputable gas supplier and visually inspecte...

Page 3: ...r appliance Never test for gas leaks with a lit match or open flame Never light barbecue with hood closed or before checking to ensure the burner tubes are fully seated over gas valve orifices Never l...

Page 4: ...AND CYLINDER EXCHANGE DISCONNECT HOSE AT THE CYLINDER ONLY DO NOT DISCONNECT HOSE FROM APPLIANCE REMOVE TRANSIT PACKAGING MATERIAL BEFORE USE IMPORTANT Do not smoke when attempting to ignite the barb...

Page 5: ...leakage between the bottle and the regulator 4 Push down a control knob and keep pressing whilst turning anti clockwise to the HIGH position a clicking sound is heard this will light the burner If th...

Page 6: ...eel parts of this appliance are made from 304 430 grade stainless steel To preserve the appearance and corrosion resistance of the stainless steel material regular cleaning is required Although stainl...

Page 7: ...ays rub or wipe in the direction of the surface grain or original polish lines Some stainless steel cleaners may damage painted or plastic surfaces read the directions carefully Flash Back Spiders and...

Page 8: ...H in either the front or the rear should be incorporated within the cabinet Please refer to diagram below as an example 916mm 580mm BENCH CUT OUT DIMENSIONS 936mm 612mm The cutout size when sitting t...

Page 9: ...up the drip tray could protrude out from the BBQ but aligns up with the cabinet front Those brackets essentially just push forward the drip tray for that type of set up cabinetry 50mm BENCH CUT OUT DI...

Page 10: ...and water solution and check for bubbles indicating gas leakage 6 Installation of 1 8 NPT plugged tapping accessible for test gauge connections is required upstream of the gas supply connection Warnin...

Page 11: ...C REPRESENTATIONS OF OUTDOOR AREAS The following figures are diagrammatic representations of outdoor areas Rectangular areas have been used in these figures the same principles apply to any other shap...

Page 12: ...protection requirements https sitro com au support sds For any queries or assistance call Customer Service Australia Only 1300 174 876 Hours of operation Monday to Friday 8am 5pm EST Do not return to...

Page 13: ...04296 04 21 INSTALLATION INSTRUCTIONS Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www gasmate com au Aber Living N Z www gasmate co nz SOHO DROP IN BBQ HOOD Model NO BQ1096H...

Page 14: ...2 1 2...

Page 15: ...3 3...

Page 16: ...all Customer Service Australia Only 1300 174 876 Hours of operation Monday to Friday 8am 5pm EST Do not return to place of purchase Keep your purchase receipt this will be required to make any claims...

Reviews: