7
6
Burner Operation & Ignition
System Check
1. Turn the control knob clockwise to “OFF”
position.
2. Connect the regulator to the gas bottle. Turn
the gas supply “ON” at the cylinder. Check
with the use of soapy water for any gas
leakage between the bottle and the regulator
3. Open the door then push down the control
knob and keep pressing whilst turning anti-
clockwise to the “HIGH” (a clicking sound is
heard), this will light the burner. If the burner
does not light,repeat this process.
4. If the burner still does not light, turn the control
knob to ‘OFF’ wait 5 minutes and repeat
step 3.
5. Adjust the heat by turning the knob to the
High/Low position.
6. To turn the appliance ‘OFF’, turn the cylinder
valve to the ‘OFF’ position and then the control
knob on the appliance clockwise to the ‘OFF’
position.
Problem: Burner will not ignite
Possible Reason
Solution
Valve on cylinder
is closed
Open valve on cylinder
Control knob is off
Turn knob to high
when lighting
Igniter is faulty
Use a long match
Ignition System Check
LIGHTING PROCEDURE
LCC27 Cylinder Connection Device