background image

3

2

8.  DO NOT use any pressure regulator or hose assembly  
 

other than those supplied with the appliance.

 

Replacement pressure regulator and hose assembly   

 

must be those specified. Replacement parts may be   

 

obtained from the distributor.

9.  Installation and use of this appliance must conform with
 

New Zealand Standard 5601 “Gas Installations”.

10. This appliance is designed to operate with a standard
 

9Kg LPG cylinder with Approved Cylinder Connection.

11. The valve outlet must be maintained in good condition.
 

When the cylinder is not in use, be sure to cover it with

 

a dust cap. A leak test should be performed with soapy

 

water whenever connecting a new cylinder. NEVER use

 

a flame to test for leaks.

12. The LPG cylinder must be turned off whenever the
 

appliance is not in use. When the appliance is to be   

 

stored indoors, the LPG cylinder and the appliance must

 

be disconnected and the cylinder stored in accordance

 

with LPG Dangerous Goods Regulations. 

13. Store the appliance upright in an area sheltered away
 

from weather conditions. The use of a cover is  

 

 recommended.

SAFETY FEATURES

The appliance has been designed with several safety 
features which include a tip over switch and a flame 
safeguard system which means if the pilot goes out it will 
automatically turn off. 

Regulator Safety Feature

All QCC regulators (the part that attaches to the gas 
cylinder to regulate the flow of gas) have a safety feature 
included that restricts gas flow in the event of a gas leak. 
You can inadvertently activate this safety feature without 
having a gas leak. This typically occurs when you turn on 
the gas using the appliance control knob before you turn on 
the gas cylinder valve. If the gas regulator safety feature 
activates, the appliance will operate with reduced output as 
gas flow is restricted. 
These steps should be taken first to reset the gas regulator
safety device:

1.  Turn gas cylinder valve off.
2.  Turn appliance off.
3.  Disconnect the regulator from the gas cylinder.
4.  Wait 30 seconds.
5.  Reconnect the regulator to the gas cylinder.
6.  Leak test the connection using a soapy water solution.
 

Ensure no bubbles appear before proceeding.

7.  Slowly open the gas cylinder valve all the way. Do not
 

put excessive force on the valve at the full open  

 

 

position, to avoid damaging the valve.

8.  Light the appliance as per the instructions provided. 

Any modification to the appliance not described in the
installation instructions may compromise the safety of this
appliance. Special concern is as follows:

 

(1) DO NOT bypass thermocouple safety burner;

 

(2) DO NOT operate appliance without the guards or  

 

     reflector;

 

(3) DO NOT shorten post length;

Clothing or other flammable materials should not be hung
from the appliance, or placed on or near the appliance.
The area above the post may be extremely hot.
Direct contact with these metal surfaces should be avoided
in order to prevent burns or clothing ignition. 

Q.C.C. Cylinder Connection Device 

Screw the coupling nut of regulator into the cylinder valve outlet. 

Minimum Clearance from Combustibles:

Side

600mm

Rear

600mm

Ceiling

600mm

Below

830mm

340

900

830

535

600

Side Clearance

600

Top Clearance

30

Gas

Connection

Point

Summary of Contents for GM120-001

Page 1: ... service or maintenance can cause injury or property damage Read the instructions thoroughly before installing or servicing this appliance OPERATES ON LPG CARBON MONOXIDE H This appliance can produce carbon monoxide which has no odour Using it in an enclosed space eg boat caravan tent car campervan or house may cause death CARBON MONOXIDE HAZARD This appliance can produce car monoxide which has no...

Page 2: ...plexiglas or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or plastered Additional clearance may be required for glass painted surfaces and other materials which may be damaged by radiant or convection heat 4 The appliance must be located on a solid table which should be situated on a level and ad...

Page 3: ...n inadvertently activate this safety feature without having a gas leak This typically occurs when you turn on the gas using the appliance control knob before you turn on the gas cylinder valve If the gas regulator safety feature activates the appliance will operate with reduced output as gas flow is restricted These steps should be taken first to reset the gas regulator safety device 1 Turn gas cy...

Page 4: ...e turn cylinder off and tighten joint Wait 5 minutes before re testing and use a soapy water solution to check the joint If bubbles appear the connection will need to be re tightened Refer to page 6 for more detailed instructions on connecting the appliance to the cylinder Disconnecting 1 Ensure the burner control is in the OFF position 2 Ensure cylinder valve is in the full off position For stora...

Page 5: ... Attach flame screen to the base of burner using 3 16 bolts and washers STEP 3 Fix the safety guard by inserting the shanks to the notches on the burner base STEP 4 Secure the reflector with 3 pcs washers 3 pcs castle nuts STEP 5 Connect the gas hose to the heater see instructions on the next page ...

Page 6: ...heater is turned OFF at this point DO NOT ATTEMPT TO LIGHT THE HEATER STEP 8 Use a solution of soapy water dishwashing liquid and water is fine Brush it on or use a spray bottle as shown in the drawing Ensure the connections have a good coating STEP 9a If the connection is leaking bubbles will start to grow in the soapy solution If this happens shut off the gas supply at the cylinder STEP 9b Tighte...

Page 7: ...eep control knob pressed for 15 seconds then turn the control knob to LOW If the pilot flame doesn t ignite immediately turn control knob to OFF and wait 2 minutes between ignition attempts for gas to dissipate 3 For maximum heat turn control knob to HIGH 4 To turn off turn the control knob to PILOT Then press and turn the control knob to OFF 5 Turn off the valve on the gas cylinder and disconnect...

Page 8: ...d Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www gasmate com au Aber Hamilton N Z www gasmate co nz Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www sitro com au Aber Hamilton N Z www gasmate co nz SAFE APPLIANCE LOCATIONS This appliance shall only be used in an above ground open air situation with natural ventilation without stagnant areas where gas l...

Page 9: ...9 ...