8. DO NOT use any pressure regulator or hose assembly
other than those supplied with the appliance.
Replacement pressure regulator and hose assembly
must be those specified. Replacement parts may be
obtained from the distributor.
9. Installation and use of this appliance must conform with
New Zealand Standard 5601 “Gas Installations”.
10. This appliance is designed to operate with a standard
9Kg LPG cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good condition.
When the cylinder is not in use, be sure to cover it with
a dust cap. A leak test should be performed with soapy
water whenever connecting a new cylinder. NEVER use
a flame to test for leaks.
12. The LPG cylinder must be turned off whenever the
appliance is not in use. When the appliance is to be
stored indoors, the LPG cylinder and the appliance must
be disconnected and the cylinder stored in accordance
with LPG Dangerous Goods Regulations.
13. Store the appliance upright in an area sheltered away
from weather conditions. The use of a cover is
recommended.
SAFETY FEATURES
The appliance has been designed with several safety
features which include a tip over switch and a flame
safeguard system which means if the pilot goes out it will
automatically turn off.
Regulator Safety Feature
All QCC regulators (the part that attaches to the gas
cylinder to regulate the flow of gas) have a safety feature
included that restricts gas flow in the event of a gas leak.
You can inadvertently activate this safety feature without
having a gas leak. This typically occurs when you turn on
the gas using the appliance control knob before you turn on
the gas cylinder valve. If the gas regulator safety feature
activates, the appliance will operate with reduced output as
gas flow is restricted.
These steps should be taken first to reset the gas regulator
safety device:
1. Turn gas cylinder valve off.
2. Turn appliance off.
3. Disconnect the regulator from the gas cylinder.
4. Wait 30 seconds.
5. Reconnect the regulator to the gas cylinder.
6. Leak test the connection using a soapy water solution.
Ensure no bubbles appear before proceeding.
7. Slowly open the gas cylinder valve all the way. Do not
put excessive force on the valve at the full open
position, to avoid damaging the valve.
8. Light the appliance as per the instructions provided.
Any modification to the appliance not described in the
installation instructions may compromise the safety of this
appliance. Special concern is as follows:
(1) DO NOT bypass thermocouple safety burner;
(2) DO NOT operate appliance without the guards or
reflector;
(3) DO NOT shorten post length;
Clothing or other flammable materials should not be hung
from the appliance, or placed on or near the appliance.
The area above the post may be extremely hot.
Direct contact with these metal surfaces should be avoided
in order to prevent burns or clothing ignition.
Q.C.C. Cylinder Connection Device
Screw the coupling nut of regulator into the cylinder valve outlet.
Minimum Clearance from Combustibles:
Side
600mm
Rear
600mm
Ceiling
600mm
Below
830mm
340
900
830
535
600
Side Clearance
600
Top Clearance
30
Gas
Connection
Point
Summary of Contents for GM120-001