17
16
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the
instructions thoroughly before installing or servicing this equipment.
NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A NON-COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained.
Tools Required:
Thin (2.5mm diameter) flat Screw Driver, Adjustable spanner, Phillips head screw driver.
GAS PIPING
1. THIS APPLIANCE IS ONLY TO BE INSTALLED BY AN AUTHORISED PERSON.
2. Check with local and state plumbing and heating codes regarding sizing of the gas lines.
3. All gas pipe connections must be sealed with a gas pipe compound resistant to Natural Gas.
4. Installation of a drip leg if required in the gas supply line must conform to AS5601.
5. When checking for gas leaks, do not use an open flame. Use a soap and water solution and check for bubbles
indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping, accessible for test gauge connections, is required upstream of the gas
supply connection.
CONVERSION
ONLY