INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION - OUTDOOR USE ONLY

d.  The flame pattern at the emitter grid 

should be visually checked whenever 

heater is operated. If flames extend 

beyond surface of the emitter grid or 

black spot is accumulating on the emitter 

grid or reflector, the heater should be 

turned off immediately. The heater should 

not be operated again until the unit is 

serviced and or repaired.

e.  Any cleaning agent used on the heater 

should be of a non-combustible and non-

corrosive nature.

f.  The stainless steel emitter grid normally 

does not require cleaning and should 

NEVER be painted.

7.  The hose must be protected from contact 

with hot or sharp surfaces both during use 

and while in storage. The hose assembly 

should be visually inspected prior to each 

use of the heater. If excessive abrasion or 

wear is evident, or the hose is cut, it must 

be replaced prior to operating the heater. 

The replacement hose assembly may be 

obtained from the manufacturer.

8. 

DO NOT use any pressure regulator or hose 

assembly other than those supplied with the 

appliance. Replacement pressure regulator 

and hose assembly must be those specified. 

Replacement parts may be obtained from 

the manufacturer or your local sales  

representative.

9.  Installation and use of this heater must 

conform with local codes or, in the 

absence of local codes, with the Standards 

of Storage and Handling of Liquefied 

Petroleum Gases.

10.  This heater is designed to operate with 

a standard 9Kg propane cylinder with 

Approved Cylinder Connection.

11.  The valve outlet must be maintained in good  

condition. When the cylinder is not in 

use, be sure to cover it with a dust cap. A 

leak test should be performed with soapy 

water whenever connecting a new cylinder. 

NEVER use a match to test for leaks.

12.  The gas cylinder must be turned off 

whenever the heater is not in use. When 

the heater is to be stored indoors, the 

propane cylinder and the heater must be 

disconnected and the cylinder stored in 

accordance with the Standard for Storage 

and Handling of Liquefied Gases.

13.  The heater has been designed with several 

safety features which include a tip over 

switch.

Screw the coupling nut of regulator into the 

cylinder valve outlet.

POL CYLINDER CONNECTION DEVICE

Type of Gas

Propane

Consumption

35 MJ/h

Operating Pressure

2.75 kPa

Injector Size

1.9 mm

Heater specifications can be found on the data 

label.

Any modification to the heater not described in 

the installation instructions may compromise the 

safety of this appliance. Special concern is as 

follows:
(1) 

DO NOT shorten post length;

(2) 

DO NOT bypass thermocouple safety;

(2) 

DO NOT operate heater without the reflector;

Clothing or other flammable materials should not 

be hung from the heater, or placed on or near 

the heater. The area above the burner may be 

extremely hot. Direct contact with these metal 

surfaces should be avoided in order to prevent 

burns or clothing ignition.

Summary of Contents for CH205MBODS

Page 1: ...Read the instructions thoroughly before installing or servicing this equipment Model No CH205MBODS The ideal solution for extending the season of outdoor entertaining Creates a stylish and attractive...

Page 2: ...or in the absence of local codes with the Australian Standard AS 5601 2 Adequate clearance around air openings into the combustion chamber clearances from combustible materials provisions for accessib...

Page 3: ...and Handling of Liquefied Petroleum Gases 10 This heater is designed to operate with a standard 9Kg propane cylinder with Approved Cylinder Connection 11 The valve outlet must be maintained in good co...

Page 4: ...ouse body with four M5 x 10mm long screws washers and nuts Attach the burner head upper using four M4 x 6mm long screws STEP 3 Locate the guards into the burner head support ensuring the pilot lightin...

Page 5: ...USE ONLY Minimum Clearance from Combustible Surfaces 500mm 1888mm 760mm 540mm Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable...

Page 6: ...d not spark Pilot won t stay lit Suspect thermocouple Corrosion of thermocouple contact Suspect valve Wind exceeding 16 kph Main burner will not light No gas Low gas pressure Blockage in orifice Manua...

Page 7: ...see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls t...

Page 8: ...all Customer Service Australia Only 1300 174 876 Hours of operation Monday to Friday 8 30am 5 30pm EST Do not return to place of purchase Keep your purchase receipt this will be required to make any c...