Note: The supply line must be equipped with an approved manual shutoff valve.
This valve should be located in the same room as the cooktop and should be in a
location that allows ease of opening and closing. Do not block access to the
shutoff valve. The valve is for turning on or shutting off gas to the appliance.
Once regulator is in place, open the shutoff valve in the gas supply line.
Wait a few minutes for gas to move through the gas line.
Gas Connection And Check
The cooktop valve is in the closed state, open the gas supply valve, coated
the connector with moderate amounts of soapy water, if there is air bubbles that it
means there is leakage, tighten the connector and test again. If repeat 3 to 4
times and there is still air bubbles, notify professionals to deal with it.
* Note: Leak testing of the appliance shall be conducted according to the
manufacturer’s instructions. The inspection places as below picture:
Manual shutoff valve
open position
To gas cooktop
To gas supply line
Fig.17
Leakage test places
17