MDE-4363G Atlas™ Fuel Systems Owner’s Manual · August 2018
Page 3-25
Changing the Price for the Mechanical Retail Pump
The Atlas Fuel System
Changing the Price for the Mechanical Retail Pump
Atlas (Gallon unit of measure)
Temporary pricing must have already been entered into the unit as outlined in the purging
section to allow dispensing and calibration. Follow the procedures given below:
• Current production Atlas pumps/dispensers are pre-calibrated to US gallons and
programmed to default programming values.
Note: Calibration verification is still required.
• They may be operated and purged in normal mode after entering the prices (add pricing
programming information from service manual or for mechanical units, from the
directions on the outside of the computer).
• Purging can be performed for units eventually to be converted to metric mode, when the
unit is in the gallon mode.
Figure 3-15: Mechanical Retail Pump PPU
Note: This section and the diagrams pertain to the mechanical models only.
1
Unlock and remove the front panel. Repeat this procedure for the other side.
2
The variator section of the computer register(s) is exposed to allow price changes. Slide the
variator cover of the computer register apart, to expose the price range arms.
Variator
Note: Directions for changing the price can be found on the outside of the variator cover.