GAS AirOzone 150 User Manual Download Page 2

The AirO

3

zone uses ozone 

to completely remove 

odours from polluted air. 

When using the AirO

3

zone, 

safety precautions need 

to be observed. Therefore 

please read these 
instructions very carefully.

Safety instructions 

The AirO

3

zone is exclusively for 

industrial use. 

Warning electric shock

The AirO

3

zone generator 

makes use of high voltages. 

Do NOT touch conducting 

(metal) parts, inside the 

body of the AirO

3

zone when 

connected to the mains (230V)

Warning harmful GAS

Never turn on the AirO

3

zone 

unless it is correctly sealed into 

duct work, and air is flowing. 

Ozone is very harmful in high 

concentrations.

Installation instructions

AirO

3

zone should be installed in a ventilation duct after your fan and filter. At least 

five metres of ducting should be used after the AirO

3

zone, this is to let the ozone have 

sufficient time to react with the odours in the air.

The Ozone and air must be ducted outside.

The air from the duct cannot go to a closed area because of the high concentration 

of ozone. The ozone from the AirO

3

zone will react with odours in the air. All odours 

will be destroyed. It is possible that more ozone is produced than necessary to remove 

all the odours. 

Diameter (mm)

150

200

250

315

Ozone plates

1

2

3

5

Max Air Capacity (m

3

/h)

600

1200

1800

3000

Max power (w)

10

20

30

50

Ambient temperatures °C

-20°C + 50°C

Max Humidity

80%*

*Ozone production reduces with high  humidity.

Fully Serviceable

AirO

3

zone is a quality product made in the EU, however over time the corona 

discharge plates oxidise. Global Air Supplies can replace the plates. Contact us for 

more information.

 

[email protected]

Technical Data

CAUTION

CAUTION

Reviews: