When the gas flow is blocked, the detector will go into alarm and disable the 

pump. Press the power/menu button to reactivate the pump.

Icon

Description

1

Alarm Condition

2

Pump Status

3

Calibration/Test Mode

4

Battery Indicator

5

Gas Readings

6

Gas Identifiers

6

5

1

3

2

4

READ FIRST BEFORE OPERATION

The Multi Gas Clip Pump

 is a personal safety device designed to detect the 

presence of hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and 

combustible gases (LEL). Before operation, ensure that you have been properly 

trained on the use of the detector and the appropriate actions to take in the 

event of an alarm condition.

Display Components

When a Gas Reading (5) exceeds its alarm threshold, the detector will go into
visual, vibrating and audible alarm. On the display, the   icon will appear

beside the Alarm Condition (1) and the associated Gas Identifier (6) will flash

off and on continuously.

 

Warning

 - Users must familiarize themselves with the icons in both

 

alarm and non-alarm states.

 

Warning

 - If the display is missing icons, or cannot be clearly read,

 

discontinue use and contact Gas Clip Technologies.

 

Warning

 - 

The IR LEL sensor will not detect hydrogen (H2) or acetylene

 (C2H2) gases however, due to their cross-sensitive nature, the CO sensor

 

will go into alarm well below 10% LEL.

Factory Default Alarms 

Sensor

LOW

HIGH

TWA

STEL

H

2

S

10 ppm

15 ppm

10 ppm

15 ppm

CO

35 ppm

200 ppm

35 ppm

50 ppm

O

2

19.5%

23.5%

LEL

10%

20%

Turning On the Detector 

To activate the detector, press and briefly hold down the power/menu button.

Activation tone will sound. Each Gas Identifier will show a chasing “0” for the

Gas Reading while it is stabilizing and self-testing. Once all Gas Identifiers

have completed the warm up and stabilization sequence, < 65 seconds, the

detector is ready to detect all applicable gases. Display will show:

Before each use, check that the gas inlet 

and alarm port are clear of any debris or 

obstructions.

Stabilizing

Fully operational

Manually Calibrating the Detector

Continuously hold down the power/menu button through the “OFF” 

countdown and the “CAL” countdown that follows. During these countdowns, 

the detector will beep and flash 8 times with a pause between countdowns. 

Display will show:

                                                                                      (pause)

Release the power/menu button when the display shows “AUTO ZERO”                     

followed by “APPLY GAS”. Connect a hose from a demand flow regulator on a 

gas cylinder to the detector's gas inlet and apply gas. Calibration is complete 

once the detector goes into alarm and the next calibration due date is 

displayed. Turn gas off and remove hose from regulator. Display will show:

                                                                                                   

                                                                                  (connect hose)

 Note: Calibration can also be done using the MGC Pump Clip Dock.

To confirm that there are no leaks in the 

sampling system, perform a blocked flow 

test 1.) daily and 2.) any time the sampling 

system is changed.

Turning Off the Detector 

Press and hold down the power/menu button until the “OFF” countdown is 

complete. During the countdown, the detector will beep and flash 4 times 

then turn off. Display will show: