4. START USING YOUR COOKER HOOD  

 

Touch control Icons with LED display 

 

 
 
 
 
 
(1)  After  power  connection,  buzzer  will  make  a  short  sound  and  the  cooker  hood 

keeps at the stand-by mode. 

(2)  Press the “Power” button, the LED will show the pre-set fan speed level 1, the fan 

speed  will  represent  1  (low)

 

2  (middle)  &  3  (high)

 

Press  the  “Power”  button 

again,  the  fan  speed  will  circularly  run  as  1-2-3-1-2BB.

 

When  re-start  the 

operation after stop, the fan speed will run as previous selection. 

(3)  Press “Lamp” button, the light will be on, press this button again, the light will be 

off. 

(4)  When the cooker hood is working, if press the “Delay” button, the hood will go into 

the  status  of  acquiescent  working  (acquiescent  time  is  9  mins).  When  time  is 
reached, the cooker hood will stop operation.  

 

5.TROUBLESHOOTING 

Fault 

Possible Cause 

Solution 

Light on, but motor 
does not work 

Fan switch turned off 

Select a fan switch position. 

Fan switch failed 

Contact your local agent. 

Motor failed 

Contact your local agent. 

Light does not work, 
motor does not work 

House fuses blown 

Replace fuses. 

Power cord loose or disconnected 

Refit cord to power outlet. 
Switch power outlet on. 

Oil leakage 

Leakage from the oil cup 

Refer to maintenance and cleaning 
section to clean the old cup 

Leakage from the mesh filter 

Refer to maintenance and cleaning 
section to clean the mesh filter 

Lights not working 

Broken/Faulty globes 

Contact your local agent. 

Insufficient suction 

The distance between the cooker 
hood and the gas top is too far 

Refit the cooker hood to the correct 
distance. 

The cooker hood 
inclines 

The fixing screw not tight enough 

Tighten the hanging screw and make it 
horizontal. 

 

NOTE:  

Any electrical repairs to this appliance must conform to your local, state and 
federal laws.Please contact the service centre if in any doubt before 

undertaking any of the above. Always disconnect the unit from the power source when 
opening the unit. 
 
 
 

Summary of Contents for HT-3590SG

Page 1: ...1 Chimney Cooker Hood Model HT 3590SG Installation Operation Manual...

Page 2: ...2 Content 1 Safety instructions 2 Product Dimension 3 Installation 4 Start using your cooker hood 5 Troubleshooting 6 Maintenance and cleaning 7 Product Specification 8 Environment protection...

Page 3: ...he ducting has no bends sharper than 90 degrees as this will reduce the efficiency of the cooker hood Warning Failure to install the screws or fixing device in accordance with these instructions may r...

Page 4: ...or if the filters are excessively greasy Do not install above a cooker with a high level grill Do not leave frying pans unattended during use because overheated fats or oils might catch fire Never lea...

Page 5: ...r cooker hood can be connected as below picture by means of an extraction duct enamel aluminum flexible pipe or non flammable material with an interior diameter of 150mm 3 1 The cooker hood should be...

Page 6: ...t is the highest Lay the expansion pipe to the exhaust outlet Fix the expansion pipe with the outlet and put the cooker hood onto the hook ix the outside chimney bracket on the outside chimney and be...

Page 7: ...se noise levels of the cooker hood Any installation work must be carried out by a qualified competent person Do not connect the ducting system of the cooker hood to any existing ventilation system whi...

Page 8: ...itch turned off Select a fan switch position Fan switch failed Contact your local agent Motor failed Contact your local agent Light does not work motor does not work House fuses blown Replace fuses Po...

Page 9: ...loth to remove any excess moisture left after cleaning Important Using neutral detergents and avoid using harsh cleaning chemicals strong household detergents or products containing abrasives as this...

Page 10: ...ith the new carbon filters 4 Place the mesh filter 5 Connect the power supply to the wall socket NOTE Make sure the filter is securely locked Otherwise it would loosen and cause dangerous When activat...

Page 11: ...accordance with Directive 2012 19 EU It will then be recycled or dismantled to minimize impacts on the environment electrical and electronic products are potentially dangerous for the environment and...

Page 12: ...12...

Page 13: ...13 75 65 90...

Page 14: ...14 65 150...

Page 15: ...acket 3 3 expansion pipe 3 4 outside chimney bracket inside chimney ST4 30mm 15 65 75 hook 2 Pic 2 expansion pipe 3 Pic 3 outside chimney bracket outside chimney ST4 30mm 4 Pic 4 inside cable tie outs...

Page 16: ...3 5 pic 5 16 5...

Page 17: ...17 1 Power 2 Speed LED 1 1 2 3 Speed 1 2 3 1 2 3 Lamp LED Lamp LED 4 Delay 9 2 2 30 01 45 86 7 9 ABCF DA01H EGI J50K 86 7 9 ABCF DAEGIH NL M Q0O PRSTUVWXY Z _0O PRSTUVWXY Q0O Q0O a bcd cdQ0O a...

Page 18: ...18 1 40 50 2 3 2 60 1 2...

Page 19: ...19 1 2 3 4 5 HT 3590SG 220 240V 50Hz 1 5W LED 1 385W 150mm 1000Me h 13...

Page 20: ...20 2012 19 EU 1 2 3...

Page 21: ...21 Sole Agent Araytron Technology Limited Service Hotline 852 2397 3066 Fax 852 2397 3055 Website www garwoods com hk...

Reviews: