1

CONTENTS

1. SAFETY PRECAUTIONS..................................................................2
2. IMPORTANT SAFETY INSTRUCTIONS ..........................................4
3. AIR CONDITIONER FEATURES.......................................................5
4. CONTROL PANEL OPERATION.......................................................6
5. DIP SWITCHES CONFIGURATION...................................................8
6. INSTALLATION..................................................................................11

 

8. TROUBLESHOOTING.......................................................................14

 

7. CARE AND CLEANING.....................................................................13

 

Inside you will find many helpful hints on how to properly use and maintain your air 

conditioner. Just a little preventive care on your part can save you a great deal of time 

and money over the life of your air conditioner. You'll find many answers to common 

problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting 

Tips first, you may not need to call for service at all.

   

Read This Manual

!

CAUTION

   This appliance can be used by children aged 8 years and above, as well as persons 

   with reduced physical, sensory, or mental capabilities or lack of experience and

   knowledge, if they have been given supervision or instruction concerning use of the

   appliance in a safe way and understand the hazards involved. Children shall not play

   with the appliance. Cleaning and user maintenance shall notbe made by children without

   supervision. (applicable for European countries).

   This appliance is not intended for use by persons (including children) with reduced

   physical, sensory, or mental capabilities or lack of experience and knowledge unless

   they have been given supervision or instruction concerning use of the appliance by a

   person responsiblefor their safety . (applicable for other countries except those in Europe).
   Children should be supervised to ensure that they do not play with the appliance. 

   If the supply cord is damaged, it must be replaced by the manufacturer, its service 

   agent, or similarly qualified persons in order to avoid a hazard.

   The appliance shall be installed in accordance with national wiring regulations.

   Do not operate  your  air  conditioner  in  a  wet  room, such  as  a  bathroom  or  laundry  room.

    The appliance with electric heater shall  have  at l east 1  m

  eter of s pace from c ombustible

    materials.

    Contact an authorized service technician for repair or maintenance of this unit.

   Contact an authorized installer for installation of this unit.

   

   

Summary of Contents for 2498547

Page 1: ...PUMP Before using your air conditioner please read this manual carefully and keep it for future reference Model 2498546 2498547 2498548 2498549 2498550 2498551 2498552 2498553 2498554 2498555 2498556...

Page 2: ...involved Children shall not play with the appliance Cleaning and user maintenance shall notbe made by children without supervision applicable for European countries This appliance is not intended for...

Page 3: ...e fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause machine failure or electric shock It may cause fire and...

Page 4: ...etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the pow...

Page 5: ...thin the air conditioner The appliance shall be installed in accordance with national wiring regulations Do not use an extension cord or an adapter plug WARNING For Your Safety Do not store or use gas...

Page 6: ...lug head on some products NOTES Do not use this device to turn the unit on or off Always make sure the RESET button is pushed in for correct operation The power supply must be replaced if it fails to...

Page 7: ...ure 2 There is a 3 minute minimum compressor runtime at any setting to prevent short cycling The indoor fan motors starts before the compressor and stops after the compressor cycles off 3 Push S1 on t...

Page 8: ...e unit displays LC pads on the control panel are not available The unit can be set with a wire controller only You can install the accessory on the control panel NOTE For some models there is a corres...

Page 9: ...20 C 24 C Two configurations S4 S5 combine to select set point range S6 S7 Fan Continuous Run for Heating Fan Cycle for Heating Fan Continuous Run for Cooling Fan Cycle for Cooling Electric Heat Only...

Page 10: ...the dip switch to the DOWN OFF position as shown below Insert the wire connector of the wall t into the relevant terminal according to different shapes as shown below hermostat Terminal of some types...

Page 11: ...High fan is desired wire the G output from the themostat to HI FAN on the unit s terminal block The range of set temperature of must match the range of DIP switch setting must be set to match the uni...

Page 12: ...and exhaust airflow See Fig 2 CAUTION There are sharp edges that can cause serious cuts When lifting the air conditioner VY people to lift COOLED AIR INTAKE AIR WALL WALL HEAT RADIATION SLEEVE Over 2...

Page 13: ...with 4 screws and washers supplied in the SLEEVE ASSEMBLY through the unit flange holes See Fig 7 and Fig 8 Fig 7 Fig 8 1 2 Fig 9 Place tabs over top rail Push Inward at bottom until panel snaps into...

Page 14: ...t thing you can do to maintain unit efficiency is to clean the filters once every two weeks as required CAUTION Failure to follow this caution may result in equipment damge or improper operation Do no...

Page 15: ...f F UNIT MAKING NOISES Clicking gurgling and whooshing noises are normal during operation of unit WATER DRIPPING OUTSIDE If a drain kit has not been installed condensation runoff during very hot and h...

Page 16: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...