 7

www  GarrettCom  com

.

.

Terminal block for -48v DC input (range of 46 to 60V dc), built in for +, - , ground. The 8-
15V DC jack is also present, but it can only be used to power the PS14P unit itself, not PoE 
devices attached. 

POWER OUTPUT: (PS14P(POE) unit only) 

PoE available on all four RJ-45 ports via Ethernet twisted pair cabling on port pins using 
spare  pairs 4,5(+) 7,8(-), not the data pair 1,2(-), 3,6(+) 
802,3af Power Consumption: 61.6 watts max. (15.4(max)/port) 
PoE Ports Output voltage: 44 to 57 VDC 
Over Current Protection, per port: resettable fuse 

 

Port Connectors:

 

RJ-45 Port:  Auto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin 
female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded 
(STP) and unshielded (UTP) Cat 3, 4, 5 cable. For PoE pass-through option on P 
models, use Model # PS14P. 

 

 
 

Summary of Contents for Magnum PS14P

Page 1: ...Magnum S14 Convenient Switch PS14P Power Source Switch PoE...

Page 2: ...E Convenient Switches Installation and User Guide Part 84 00100 Rev B 01 06 Trademarks GarrettCom Magnum Link Loss Learn S Ring Convenient Switch and Converter Switch are trademarks and Personal Hub i...

Page 3: ...tatement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference...

Page 4: ...nvenient Switches Installation and User Guide 01 06 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr F...

Page 5: ...06 TABLE OF CONTENTS Page 1 0 SPECIFICATIONS 1 1 1 Technical Specifications 1 2 0 INTRODUCTION 11 2 1 Inspecting the Package and the Product 12 2 2 Product Description 13 2 3 Magnum PS14P S14 Series w...

Page 6: ...ement for PS14P PoE Power Source Switch 54 3 8 Connecting Twisted Pair RJ 45 ports 55 3 8 1 Connecting Twisted Pair Unshielded or Shielded 56 3 8 2 Connections to NICs which support Auto Neg RJ 45 por...

Page 7: ...ower supply option 09 04 Small edit and updates on UL 06 04 Small revision of the Agency Approvals Rev A 03 04 Initial release of this user manual for the S14 Converter Switch GarrettCom Inc reserves...

Page 8: ...ent Switches Installation and User Guide 01 06 1 0 SPECIFICATIONS 1 1 Technical Specifications Ports Performance When a port is operating at 100Mbps Data Rate 100Mbps When a port is operating at 10 Mb...

Page 9: ...rwarding Rate from 100Mbps ports 148 800 pps max Filtering and Forwarding Rate from 10 Mbps ports 14 880 pps max Processing type Store and Forward non blocking Auto learning 2K address table Address b...

Page 10: ...ng Environment Ambient Temperature S14 32 F to 104 F 0 C to 40 C S14H 13 F to 140 F 25 C to 60 C Long term per independent agency tests UL 40 F to 167 F 40 C to 75 C Short term per IEC Type tests S14P...

Page 11: ...models are designed for NEBS compliance including vibration shock and altitude Packaging Enclosure Robust sheet metal Steel Dimensions Switch unit Height x Width x Depth S14 S14H S14P PS14P 3 5 in H...

Page 12: ...or a Listed ITE Power Supply marked LPS which has suitably rated output voltage i e 9vdc 12vdc 24vdc 48vdc and suitably rated output current i e 100mA to 500mA When connected to a 48 V centralized dc...

Page 13: ...on and User Guide 01 06 DC to unit 12V DC 2 5mm jack center ve 6ft cord Power Supply Direct DC built in screw terminal block for ground The 12V DC jack is also present 12V DC internal range of 8 0 to...

Page 14: ...an only be used to power the PS14P unit itself not PoE devices attached POWER OUTPUT PS14P POE unit only PoE available on all four RJ 45 ports via Ethernet twisted pair cabling on port pins using spar...

Page 15: ...4 has front only POWER Steady ON when power applied S14 model ON for 48V power applied to the PS14P unit PoE ports 1 2 3 4 ON when delivering power PS14P 10 100 100Mbps OFF 10 Mbps LK ACT Steady ON fo...

Page 16: ...60950 cUL CE Emissions meet FCC Part 15 Class A NEBS L3 and ETSI compliant H P models IEEE P1613 Env Std for Electric Power Substations P model NEMA TS 2 and TEES for traffic control equipment P mode...

Page 17: ...y S14H Hd Hi Hardened four 10 100 RJ 45 ports Switch Factory floor Int 8 15VDC Ext AC Hardened power supply included S14H 12VDC Same as S14H model except Ext AC Hardened power supply not included S14H...

Page 18: ...age rated for un controlled outdoor env All four RJ 45 Ethernet ports support Power Source PoE as per the IEEE 802 3ad standard Includes integral 48V DC terminal block for power unit NOTE If you want...

Page 19: ...ner for obvious damage prior to installing this product notify the carrier immediately of any damage which you believe occurred during shipment or delivery Inspect the contents of this package for any...

Page 20: ...unit at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container Refer to Section 5 Troubleshooting for sp...

Page 21: ...oE Convenient Switches Installation and User Guide 01 06 GarrettCom A1 LA3 F H A2 PWR PORT 2 P O R T 3 P O R T 4 LK AC T 10 100 3 2 PORT 4 PORT 1 PORT 2 PORT 3 10 100 LK A C T LK ACT 10 100 10 100 LK...

Page 22: ...upply A metal case with convection cooling is featured Operation may be in 0 to 50 C ambient temperature The units can be mounted securely on a closet wall or metal cabinet or by using the metal panel...

Page 23: ...1 06 GarrettCom LA3 F H PWR PORT 2 PO R T 3 P O R T 4 LK AC T 10 100 3 2 PORT 1 PORT 2 PORT 3 10 100 LK A C T LK ACT 10 100 10 100 LK A C T POWER Ambient temperature rating is up to 25 C to 60 C for a...

Page 24: ...T 2 PORT 3 10 100 LK A C T LK ACT 10 100 10 100 L K A C T POWER The red label Magnum S14P as shown in Fig 2 2e is a premium rated unit suitable for temperature un controlled outdoor applications Speci...

Page 25: ...nuous efforts of designing reliable and premium rated Industrial Ethernet products with the latest technology while being a cost effective solution has successfully yielded their first Industrial PoE...

Page 26: ...ernet cables So a single Ethernet twisted pair cable will be able to transmit voice data and power from the attached devices The PS14P switches are Power Sourcing Equipment PSE and are fully compatibl...

Page 27: ...compliant way to power and connect a few small Ethernet devices at the edge of a network where AC power is not cost effective to deploy Since PoE is rapidly emerging as an Ethernet option in industri...

Page 28: ...ide 01 06 These are applications where the Magnum PS14P can be used to provide the power and data for these PoE Powered Devices which require 12 13watts maximum Wireless LAN access points and WLAN Mob...

Page 29: ...rst worldwide standard power plug The futuristic applications of PoE look promising as a convenient point providing Notebook computer Cell phone charger and PDA games through the PoE devices The sleek...

Page 30: ...models come with two 2 sets of LED indicators One set is mounted in the end adjacent to three of the RJ 4 ports for easy viewing when the unit is mounted in a rack mount tray The Magnum PS14P Power S...

Page 31: ...used to power the PS14P unit when no PoE devices are attached While using a 12vdc Adaptor to power on the switch the unit will not function as a PoE power source switch but as a non PoE switch only 2...

Page 32: ...n the top of the unit as well as the end LEDs mounted next to each port indicate LK ACT as LA1 LA2 LA3 LA4 10 100 ON for 100Mbps and full half duplex F H is ON for full duplex The DC power plug connec...

Page 33: ...ad frames to propagate out to the Ethernet segments connected This cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the networ...

Page 34: ...observer See Section 4 6 for additional details Another feature implemented in Magnum S14 Series PS14P PoE Convenient Switches is a collision based flow control mechanism when operating at half duple...

Page 35: ...pplications Expansion of Ethernet connectivity is needed to connect edge devices into the LAN the Magnum S14 Series Switches provide 10 100 switching in a convenient and compact package that fits righ...

Page 36: ...hes operate as LAN switches only forwarding those packets from each domain that are needed on the other domains Internal address tables are self learning All ports are auto cross Two sets of LEDs for...

Page 37: ...iety of types external AC and internal DC at 12V 24V or 48VDC AC may be at extreme temperatures DC input models can operate as dual source S14 series The 12V DC jack is present on DC input models so t...

Page 38: ...t Compact design for all purpose convenient mounting Featuring a compact metal case Magnum S14 Series PS14P POE can be installed in minimal space in a rack mount MC14 TRAY on DIN Rail optional or pane...

Page 39: ...h for high performance Port 1 on the back end is typically used for an up stream connection When expansion is needed add another S14 and connect it into port 1 with twisted pair cabling to add 3 more...

Page 40: ...T LK ACT 10 100 10 100 L K A C T PO WER GarrettCom Magnum S14 Convenient Switch LA1 LA3 F H LA2 PWR 0 PORT 1 PORT 2 P O RT 3 P O R T 4 L K AC T 10 100 P 3 2 1 PORT 4 PORT 1 PORT 2 PORT 3 10 100 L K A...

Page 41: ...ers Any attached node can change speed at any time without affecting network operation or impacting other users The multi functional S14 Convenient switches provide this solution very efficiently and...

Page 42: ...PWR PORT 1 PO RT 2 PO RT 3 PO R T 4 L K ACT 10 100 3 2 1 PORT 4 PORT 1 PORT2 PORT 3 10 100 L K A C T LK ACT 1 0 1 00 10 100 L K A C T PO WER GarrettCom Magnum S14 Convenient Switch LA1 LA3 F H LA2 PW...

Page 43: ...of options of AC and DC power supplies the cost effective Magnum S14Hs Convenient Switches easily qualify to be used in highly controllable industrial applications The S14H Switches act as a network...

Page 44: ...es Installation and User Guide 01 06 Magnum 6K25 W W W G a r r e t t C o m C o m IBM Compatible M a g n u m m P 6 2 G arrettC om and Workstations 100Mb Servers 100 and Workstations 100Mb Servers 100 M...

Page 45: ...l solution for any temperature un controlled environments This sleek designed convenient Switch can easily meet the ongoing demand of a growing network Example 4a Magnum PS14P Power Source Switch for...

Page 46: ...Magnum S14 Convenient Switch GarrettCom Magnum S14 Convenient Switch L A L A F H L A P W 10 10 0 P O R P O R P O R P O R L K 1 0 9 V D C PORT PORT PORT PORT WWW GarrettCo 1 0 L K L K 1 0 1 0 L K P O...

Page 47: ...power Source Switch capability easily meets the demand to provide power through its RJ 45 cable and allows for a very neat Network setup The Magnum PS14P POE is enabling the efficient deployment of r...

Page 48: ...ower IBM IBM Router Router GarrettCo Magnum S14 Convenient Switch LA 1 LA 3 F H LA 2 PW R 10 100 P O P O P O P O L K 1 0 9 V D C POR POR PORPOR 48vdc power IBM GarrettCo Magnum S14 Convenient Switch L...

Page 49: ...ON This section describes the installation of the Magnum S14 Series PS14P PoE Convenient Switches including location mountings power supply and media connection 3 1 Locating the Convenient Switch Unit...

Page 50: ...an AC power outlet or power strip and where convection cooling is not inhibited The green Power PWR Led must turn ON when power is applied through the internal DC input 12V 24V or 48V DC or external...

Page 51: ...e mounting spaces of the MC14 TRAY are specific to the S14 series and do not permit other models A typical installation of the model MC14 TRAY 19 rack mount tray will hold a few often three to eight S...

Page 52: ...itches for MC14 TR PS9 and 16 units S14 Series for MC14 TR PS9X2 The MC14 TR PS9X2 Model has two groups of eight units per power supply These models are equipped with auto ranging AC input to the powe...

Page 53: ...verters each with their power input plugged into the built in common AC power supply in the rear area of the tray PS units that come with the MC s are not used Metal mounting screws in the bottom fron...

Page 54: ...ches designed for use in Factory Floor Industrial Ethernet environments are also available for DIN Rail mounting in an enclosure having DIN Rails The metal DIN Rail mounting hardware is optional and n...

Page 55: ...power and have the DIN Rail MC2 bracket included and assembled with the MC unit at the factory 3 5 Power Requirements Power Supply Types for S14 Series Switches Magnum S14 Series Switches are power ef...

Page 56: ...on and User Guide 01 06 The S14 Series are designed to provide reliable operation withstand higher temperature environments and provide the Direct DC power choices to the user to deploy in uncontrolle...

Page 57: ...and User Guide 01 06 3 6 Powering the S14H S14P DC internal with 12V 24V or 48VDC power input Each Magnum S14H S14P is reliably equipped with a Direct DC power supply and have built in screw terminals...

Page 58: ...er Guide 01 06 present and optionally can be used with an external P rated AC power supply to provide dual source power input DC Power Terminals floating GND Terminal for earth or ground wire connecti...

Page 59: ...1 06 3 7 S14H S14P DC powered 48VDC 24VDC and 9VDC Installation This section describes the proper connection of the 48VDC leads or 24VDC 12VDC leads to the Direct DC power terminal block on the Magnum...

Page 60: ...s power terminals positive and negative screws The use of Ground GND is optional it connects to the S14H chassis Ensure that each lead is securely tightened from the top as shown here NOTE Always use...

Page 61: ...l block for 48v DC input range of 46 to 60V dc built in for ground Note The 8 15V DC option is also present but can only be used to power the PS14P POE unit when no PoE devices are attached The device...

Page 62: ...P POE Convenient Switches can be connected to only one media type with two different speed i e 100BASE TX and 10BASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are...

Page 63: ...connect a 10BASE T or 100BASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert eithe...

Page 64: ...eries Convenient Switches will function properly with NICs Network Interface Cards which support Auto Negotiation and the Fast Link Pulse FLP coding for the 100BASE TX signaling system When connecting...

Page 65: ...PoE Convenient Switches provide four switched ports three ports in the front and one on the rear The architecture supports a dual speed switching environment with auto negotiation capability The swit...

Page 66: ...on is taken to either filter or to forward the packet Packets whose source and destination addresses on the same port segment will be filtered constraining them to one port and relieving the rest of t...

Page 67: ...Address Learning The Magnum S14 Series PS14P PoE units have address table capacity of 2K node addresses and are suitable for use in large networks They are self learning so that as nodes are added or...

Page 68: ...he manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in the S14 and PS14P PoE Switches will still work The auto cross function cannot be disabled When an R...

Page 69: ...lluminates GREEN to indicate power applied LK ACT Steady ON for LINK w no traffic blinking for activity per port LINK will turn off in the event connectivity is lost between the ends of the twisted pa...

Page 70: ...t products are designed to provide reliability and consistently high performance in all network environments The installation of Magnum S14 Series PS14P PoE 10 100 Mb s Switches is a straightforward p...

Page 71: ...allation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they hav...

Page 72: ...ctioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum S14 Series PS14P PoE 10 100 Mb s Switch unit or if unknown contact GarrettCom Inc by fax...

Page 73: ...terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to sys...

Page 74: ...iption of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sen...

Page 75: ...ould be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing m...

Page 76: ...p for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defectiv...