GarrettCom Magnum P62-Series Installation And User Manual Download Page 33

Magnum P62-Series Hardened Switches                               Installation and User Guide (12/02)

29

www  GarrettCom  com

.

.

An address-aging algorithm causes least-used addresses to fall out in favor of new

frequently-used addresses.  To reset the address buffer, cycle power down-and-up.

4.2

Auto-negotiation and Speed-sensing

All six RJ-45 ports independently support auto-negotiation for speed in 10BASE-T and

100BASE-TX modes. Operation is according to the IEEE 802.3u standard.

When a RJ-45 cable connection is made, and each time a LINK is enabled, auto-

negotiation takes place. The P62-Series advertises its capability for 10 or 100 Mbps speed, and

the device at the other end of the cable should similarly advertise / respond and both sides will

agree to the speed being used.  Depending upon the device connected, this will result in

agreement to operate at either 10 Mbps or 100Mbps speed.

When the ‘

LK/ACT’

 LED is ON, steady ON indicates LINK with no traffic, blinking

ON indicates the port is transmitting / receiving.  The port has auto-negotiated for operation. (If a

P62s RJ-45port is connected to a non-negotiating device, it will default to 10 Mbps speed and

half-duplex mode, per the IEEE 802.3u standard).

4.3          LED’s for P62-Series Hardened Switch

POWER: 

Illuminates GREEN, steady on when power applied.

SELF TEST:

Indicates the self-test at power up was not successful.

F/H:

ON = Full-Duplex and Link, OFF = Half-Duplex and / or no Link.

LK/ACT: 

Per port, steady ON for LINK with no traffic, blinking indicates port is

transmitting and receiving.

10/100:

Per port, ON = 100Mbps; OFF = 10 Mbps (when LINK is made).

Summary of Contents for Magnum P62-Series

Page 1: ...www GarrettCom com Magnum P62 Series P62F and managed mP62 models Hardened Ethernet Switches Installation and User Guide...

Page 2: ...h and Link Loss Learn patent pending are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum P62 Series Hardened Ethernet Switches contain no user serviceable...

Page 3: ...e frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found t...

Page 4: ...100 and 2 100Mb fiber ports managed and unmanaged models all fiber types Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing AC and DC power Dual Speed 8 port and 16 port Stackables 10 100 au...

Page 5: ...iber Optic 22 3 2 5 Power Budget Calculations for P62 Series Fiber Media 23 3 2 6 Connections to NICs which support Auto Negotiation RJ 45 ports 24 3 3 Powering the Magnum P62 Series Hardened Switch 2...

Page 6: ...Mbps ports 14 880 pps max Processing type Store and Forward Auto learning 4K address table 16K on P62F shared for all ports Packet buffers 256KB dynamically shared on all domains Latency not includin...

Page 7: ...and 10 100 speed each inde pendently auto negotiating on P62F models S W controlled on mP62 models Fiber Ports 1 and 8 The switched fiber ports 1 8 are fixed at full duplex only 100Mb speed Mechanica...

Page 8: ...TBF Email sales GarrettCom com for details Agency Approvals UL Listed UL 60950 cUL CB CE Low Volt Dir Electro Magnetic Comp IEEE P1613 Draft Environmental Standard for Electric Power Subs C37 90 Emiss...

Page 9: ...that filters and forwards data moving between the ports The internal switch has 16K nodes address table and 1MB packet buffers DC power input 18 70VDC auto ranging Steel case acts as a heat sink Rated...

Page 10: ...e ports Software and buffers same as mP62 AC 2MSC Dc power input 18 70VDC auto ranging Magnum mP62 1MISSC Same as mP62 2MSC except one fiber port is 20km single mode SC No PSX unit required Magnum mP6...

Page 11: ...tion and User Guide 1 Product Registration Card Optional if AC power 1 PSX A Power Source Extended Temp unit 1 6 ft long AC Power chord for PSX A Unit only Optional PSX T 125 or 250VDC 1 PSX T Power S...

Page 12: ...provide the switching speed and the reliability to smoothly support multiple workgroups at 100Mbps or 10Mbps speed The optional fiber ports are normally configured and tested with Magnum P62 units in...

Page 13: ...her bandwidth and longer distances on fiber All the LEDs are mounted on the top cover to conveniently indicate operating status of all ports There is a power on PWR indicator and a SELF TEST self test...

Page 14: ...Magnum mP62 5V mP62 5V with the PSX A AC model The Managed mP62 model is equipped with industry standard network management and utility software operating features to make this Switch suitable to dep...

Page 15: ...max of 75 C which is 5 C more than the P62F product ratings of 70 C Equipped with high thermal dissipation features patent pending power supply flexibility management MNS mP software capability and a...

Page 16: ...ort GarrettCom com for further information 2 2 4 Connecting the Console Terminal to Magnum mP62 Management Use a DB 9 null modem cable to connect the Magnum mP62 Console Port the RS 232 port on the mP...

Page 17: ...Magnum P62 Series unit via a cable A proper link LK light must be made between both devices at each end of the cable in order for each LINK LED to provide a valid indication of operating conditions 2...

Page 18: ...industry standard full duplex only PAUSE packets out to the devices sending packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic cat...

Page 19: ...ng in any situation As the units are normally vertical for wall or pedestal mounting top surface viewing is most convenient Installation is Plug n Play operation is transparent to software The Magnum...

Page 20: ...witch serves this requirement economically and efficiently The six full and half duplex switched ports make the required setup simple for collection of traffic data The uncontrolled outdoor temperatur...

Page 21: ...ide an exceptional Ethernet product Figure 2 6 2 Three P62F connects together to provide 10 Mbps and100Mbps network with Fast Ethernet backbone In this example the extended temperature rated P62F take...

Page 22: ...requirement The Managed mp62 equipped with STP VLAN QoS etc features provide a very economical and efficient solution to this requirement The advanced Link Loss Learn feature will provide a very secur...

Page 23: ...for high reliability and AC power for convenience in out of the way locations Locate the P62 Series unit near any AC power or any 20 70VDC three wire GND power source for DC models that is within the...

Page 24: ...62 S base plate to the vertical mounting surface The PSX Power Source mounting is similar The mechanical drawings in Figures 1 2 below provide the mounting holes measurement information for the PSX un...

Page 25: ...dth than copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode 100BASE FX SC Fiber Single mode 100BASE FX SC NOTE 1 It...

Page 26: ...the Fiber port connector until it clicks and secures Note One strand of the duplex fiber optic cable may be coded using color bands at regular intervals you should use the color coded strand on the as...

Page 27: ...lti mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km The following data has been collected from component manufacturer s HP s and Siemens web sites and catalogs to provide guida...

Page 28: ...n high reliability record DC Power Terminals internally floating GND Terminal for earth or ground wire connection to the P62 chassis Input Voltage 20 to 70 VDC Input current 0 7 amp max Power Consumpt...

Page 29: ...crew lock female plug for secure attachment to the P62 5V Switch Input Voltage 85 264 VAC 47 63HZ Auto ranging AC Power Connector IEC type male recessed Wiring Pin out P62F 5V Power Adaptor Pin 1 ve v...

Page 30: ...shown in Figure above The 125 250 VDC terminal block on the External PSX T is located on the left side of the unit and is equipped with three 3 screw down lead posts covered by a removable safety shie...

Page 31: ...provided as part of the package design The Magnum P62 Series Hardened Switches have a tie wrap holder as part of the base plate of the unit for cable strain relief The strain relief feature is applica...

Page 32: ...orts is user dependent and changes by auto negotiation to full or half duplex as the unit attached with these ports The internal functions of P62 Series Switch is described below Switching Filtering a...

Page 33: ...advertise respond and both sides will agree to the speed being used Depending upon the device connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed When the LK ACT LED...

Page 34: ...tion Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have be...

Page 35: ...s workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any...

Page 36: ...e unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the ship...

Reviews: