background image

Magnum 6KM Mobile Ethernet Switch Installation and User Guide 

07/10

 

 
 

15

www  GarrettCom  com

.

.

Pair 1

 

Pin 6 =  TX+ (MDI3+)

 

 

Pin 4 =  TX- (MDI3-) 

Pair 2  Pin 1 =  TX- (MDI0+) 
 

Pin 7 =  TX+ (MDI0-) 

Pair 3  Pin 5 =  RX+ (MDI1-) 
 

Pin 8 =  RX- (MDI1+) 

Pair 4  Pin 2 =  RX+ (MDI2-) 
 

Pin 3 =  RX- (MDI2+) 

 

Fig 3.2.2a  1000Mb 8-Pin A-Coded M12 pin configuration 

 

3.2.3 Connecting 

Single-Mode Fiber Optic 

 

When using single-mode fiber cable, be sure to use single-mode fiber port 

connectors.  Single-mode fiber cable has a smaller diameter than multi-mode fiber cable 
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx 
are the diameters of the core and the core plus the cladding respectively). Single-mode 
fiber allows full bandwidth at longer distances, up to 70km with the single-mode LC. 

3.2.4 

Connecting Fiber Optic Cable to LC ports 

1. 

Before connecting the fiber optic cable, remove the protective dust caps from  

 

the tips of the connectors. Save these dust caps for future use. 

2. 

Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens 

 

tissue dampened in alcohol.  Make certain the connectors are clean before 

 connecting. 

3.  

Connect the Transmit (TX) port on the Magnum 6KM to the Receive (RX) port 

 

of the remote device. Connect the Receive (RX) port on the 6KM to the 

 

Transmit (TX) port of the remote device. 

 

While connecting fiber media to LC connectors, simply snap on the two square 

 

male connectors into the LC female jacks of the Fiber connector until it clicks 

 and 

secures. 

The LINK LED on the front of the 6KM will illuminate and turn Green, when a proper 
connection has been established at both ends (and when power is ON in the unit). If 
LINK is not lit or OFF after cable connection, the normal cause is improper cable 
polarity.  Swap the fiber cables at the 6KM connector and also check the connectivity on 
the target device to remedy this situation. 

Reconfigure or reboot both of the devices if required. 

If connected properly, you can check via (MNS-6K) software for verifying the validity of 
SFF Gigabit ports. 

Summary of Contents for MAGNUM MAGNUM 6KM

Page 1: ...www GarrettCom com Magnum 6KM Mobile Ethernet Switch Hardware Installation and User Guide...

Page 2: ...serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6KM Switch products consult Section 6 Troubleshooting C...

Page 3: ...atement This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur le mat riel du Cana...

Page 4: ...Mobile Ethernet Switches 18 3 5 Alarm Contacts for monitoring internal power and Software Traps 19 3 6 Connecting the Console Terminal to Magnum 6KM 20 3 6 1 M12 Console Port pin assignments 20 4 0 OP...

Page 5: ...APPENDIX D AC Power Input 41 Revisions Rev A 07 10 Initial Release Rev B 10 10 Updated Electrical requirements pg ii replaced 14mil conformal coating with 8mil updated Wall mount brackets Rev C 11 10...

Page 6: ...tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking IEEE 802 1x Port based Network access control IEEE 802 3af Power over Ethernet Maximum 10 Mbps E...

Page 7: ...Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection optional Request quote Alarm Relay Contacts One NC indicating internal power one NC...

Page 8: ...ment Console connector M12 interface female see details in Section 3 6 6KM Mounting Vertical or horizontal mounting normal Suitable for wall or DIN Rail mounting Agency Approvals and Standards Complia...

Page 9: ...Same as 6KM 110VDC except the power input is 12VDC Magnum 6KM 24VDC Same as 6KM 110VDC except the power input is 24VDC Magnum 6KM 48VDC Same as 6KM 110VDC except the power input is 48VDC Magnum 6KMP 4...

Page 10: ...100 1000Mb M12 copper ports 6KM 2GMLC adds two MM 2Km 1000Mb LC fiber ports 6KM 2GSLC adds two SM 20Km 1000Mb LC fiber ports 6KM 2GSLCL adds two SM 40Km 1000Mb LC fiber ports MM Multi mode fiber SM Si...

Page 11: ...ckage should contain 1 Magnum 6KM Mobile Ethernet Switch base unit configured with user selected port module options installed 2 Set of two metal vertical mounting brackets with screws to the case 1 6...

Page 12: ...eets mns6kds pdf Magnum 6KMs are ideal for mobile networks such as on passenger railways public service and emergency vehicles shipboard mining equipment and military vehicles Applications include in...

Page 13: ...ave heavy duty steel cases and are readily available with standard Industrial grade DC power Internal AC power and DC power input types may be 12V 24V 48V 110 125V 250V and dual source DC input is opt...

Page 14: ...6K SECURE which allow the user to configure the Magnum 6KM as a Managed Switch and implements security features and other software enabled features NOTE Magnum 6KM managed switch will work with MNS 6...

Page 15: ...rations One is for hardware and will signal loss of power internally The other is software controlled and will signal user defined software events such as a security violation or an S Ring fault condi...

Page 16: ...availability They provide the flexibility of 100Mbps fiber and copper ports as well as dual Gigabit 1000Mb ports with industry standard LAN management software Magnum 6KMs are ideal for mobile network...

Page 17: ...verloading of the building s electrical circuits 5 If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This se...

Page 18: ...UTP or STP The M12 ports of the Magnum 6KM can be connected to the following two media types 100BASE TX and 10BASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are u...

Page 19: ...STP The M12 Gigabit ports of the Magnum 6KM can be connected to the media types 1000BASE T or CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable The CAT 5E or better 100 ohm UTP...

Page 20: ...ectors Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before conn...

Page 21: ...ap the bracket into holding position by moving the bottom of the 6KM inwards to a vertical position The DIN Rail bracket is heavy duty and will hold the 6KM securely in position even with cabling atta...

Page 22: ...into the metal support structure Since the 6KM has special internal thermal techniques to move the heat generated by the electronic components inside into the case the case may be quite warm to the to...

Page 23: ...options are available to suit the 6KM Mobile Ethernet Switches to special high availability communications and or heavy industrial grade applications including 12VDC 48VDC 24VDC 110VDC 125VDC and 250...

Page 24: ...gers an alarm in the user s monitoring system The second NC Alarm Contact is held closed when there is power on the main board inside of the Switch This provides a Hardware Alarm labeled H W because t...

Page 25: ...m 6KM Switch Configuration information please refer to Magnum 6K Software Manual available on GarrettCom s FTP site It is also available on GCI s website at http www garrettcom com techsupport sw_down...

Page 26: ...d ports which must be configured through MNS software per unit as per the requirement The internal functions of both are described below Filtering and Forwarding Each time a packet arrives on one of t...

Page 27: ...he remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at the...

Page 28: ...hen data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protra...

Page 29: ...is 0 2 dB km ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 Magnum 6KM Mobile Ethernet Switch Port Modules This chapter describes...

Page 30: ...upplied to the unit M12 4 pin D coded 10 100Mb 1 LED per port Link A LED ON 10 100Mb LINK established BLINKING ACTIVITY M12 PoE 4 pin D coded 10 100Mb 1 LED per port ON PoE PoE device detected M12 8 p...

Page 31: ...and User Guide 07 10 26 www GarrettCom com LC 100Mb Fiber port 2 LED per port L A LED ON LINK established BLINKING ACTIVITY F H LED ON Full Duplex OFF Half Duplex LC 1000Mb Fiber port 1 LED per port L...

Page 32: ...is a powered up device at the other end of the cable in order for a Link LED to provide valid indications of operating conditions on that port Using the 6K MNS 6K or MNS 6K SECURE management software...

Page 33: ...properly to an IEEE 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE PoE LEDs Summary For PoE de...

Page 34: ...er optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has a Link Activity L A LED indicating proper co...

Page 35: ...otiating and auto crossover MDIX for operation at 10 or 100Mb speed in full or half duplex mode i e each independently selects a mode and speed to match the device at the other end of the twisted pair...

Page 36: ...ble of distances up to 2km The 1000Mb Gigabit fiber port module on the Magnum 6KM are normally set factory default to operate at AUTO mode for best fiber distance and performance Each port has a Link...

Page 37: ...network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation Abo...

Page 38: ...URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your compa...

Page 39: ...responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants...

Page 40: ...roduct for use in 12 24 48 110 125 and 250VDC applications in different industries DC Power Terminals are internally floating so that user may ground either GND ground wire connection to the 6KM chass...

Page 41: ...This section describes the proper connection of the 12 24 48 110 125 and 250VDC to the DC power connector on the Magnum 6KM Switch The DC input connector on the Magnum 6KM Mobile Switch is located on...

Page 42: ...Connect supply line to the unit 3 Apply power to the supply line 4 Confirm that the PWR led is illuminated B4 0 UL Requirements for DC powered units CAUTION 48VDC products shall be installed with a r...

Page 43: ...to the hub chassis screw Input Two separate sources each at 36 60 VDC Power Supply Internal 110VDC Dual Source model Dual Src 110V DC Power Connector First Source A A 2nd Source B B GND ground wire co...

Page 44: ...DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is absent or even if it is connected with reverse polarity...

Page 45: ...ting live power lines to the input connector of 48VDC 12VDC 24VDC 110VDC 125VDC or 250VDC products always use a digital voltmeter to measure the output voltage of the power supply and determine the le...

Page 46: ...7 to 63 Hz auto ranging The mating power cable connection to the 6KM switch is made utilizing a RD24 locking female connector Simply align the keyed female AC power cable connector to the 6KM male AC...

Reviews: