CSG14 Series Gigabit Converter Switch
Installation and User Guide (05/08)
53
www GarrettCom com
.
.
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125
μ
m
(m.m.) is 2.8 dB/km,
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
The following data has been collected from component manufacturer’s (HP’s, and
Siemens’) web sites and catalogs to provide guidance to network designers and installers
Summary of Contents for Magnum CSG14
Page 1: ......
Page 43: ...CSG14 Series Gigabit Converter Switch Installation and User Guide 05 08 Example 3 CSG14P...
Page 45: ...CSG14 Series Gigabit Converter Switch Installation and User Guide 05 08 3 0 INSTALLATION...
Page 69: ...CSG14 Series Gigabit Converter Switch Installation and User Guide 05 08 5 0 TROUBLESHOOTING...
Page 75: ...CSG14 Series Gigabit Converter Switch Installation and User Guide 05 08...