background image

Magnum 6KQE Managed Edge Switch Installation and User Guide             02/09

 

 
 

41

www  GarrettCom  com

.

.

connection, for example, will neither affect the Switch, its internal power supply, nor will 
it blow the fuse in the internal power supply.  

 
B3.0 

 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES 

 

 

Magnum 6KQE Switches are easily installed in a variety of applications where 

12, 24, -48VDC, 125 and 250VDC power is used as the primary power source. The DC 
power configuration capability provides an Ethernet networking solution utilizing a 
special power supply in switches with a proven track record.  
 

The –48VDC solution is particularly useful in the telecommunication industry, 

where it is common for facilities to operate on -48VDC power. Such companies include 
regular and wireless telephone service providers, Internet Service Providers (ISPs) and 
other communication companies.  In addition, many high availability equipment services, 
such as broadcasters, publishers, newspaper operations, brokerage firms and other 
facilities often use a battery backup system to maintain operations in the event of a power 
failure. It is also frequently used for computer system backup, management and 
operations monitoring equipment. 
 

The 24V and 125VDC options are particularly useful in the industrial 

environment, where it is common for facilities to operate on 24VDC or 125VDC power. 
The 125VDC options are mainly used in power utilities, such as electrical substations, 
electrical generating plants, etc. The 24VDC applications are mainly in heavy duty 
industrial automation such as factory floor, process plants, HVAC, military equipment, 
etc.  

 

B4.0        6KQE, 12, 24, –48, 125 and 250VDC INSTALLATION  

 

This section describes the proper connection of the 12, 24, –48, 125 and 

250VDC leads to the DC power terminal block on the Magnum 6KQE Switch.

 

The DC 

terminal block on the Magnum 6KQE Managed Switch is located on the left front of the 
unit and is equipped with four (4) screw-down lead posts. The power terminals are 
identified as positive (+) and negative (-), and they are electrically floating inside the unit 
so that either may be grounded by the user if desired.  The chassis is “earth” or ground 
(GND).

 

 

The connection procedure is straightforward. Simply insert the DC leads to the 

Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground 
(GND) connects to the Switch chassis screw provided under the DC terminal. Ensure that 
each lead is securely tightened.  

  

NOTE:  Always use a voltmeter to measure the voltage of the incoming power supply 
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead 
will connect to the post labeled “+ve” and the rest to the “-ve”.  The GND can be 
hooked up at the last 

Summary of Contents for Magnum 6KQE

Page 1: ...www GarrettCom com Magnum 6KQE Managed Edge Switch Hardware Installation and User Guide 5 00 USD...

Page 2: ...iceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6KQE Switch products consult Section 6 Trouble Shooting Copy...

Page 3: ...anadian Emissions Statement This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur...

Page 4: ...mensions for 6KQE with metal brackets 20 3 3 1 DIN Rail Mounting the Magnum 6KQE 21 3 4 Powering the Magnum 6KQE Managed Edge Switch 22 3 5 Alarm Contacts for monitoring internal power and Software Tr...

Page 5: ...SFP Fiber ports Slot D 35 5 2 6KQEP 48VDC Base Unit w PoE Power pass through 36 6 0 TROUBLESHOOTING 37 6 1 Before Calling for Assistance 37 6 2 When Calling for Assistance 37 6 3 Return Material Autho...

Page 6: ...E 802 3ab 1000BASE X Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad L...

Page 7: ...or UL60950 and Component Parts rating 40 to 195 F 40 to 85 C for IEC 60068 Type Test short term rating Storage Temperature 60 to 210 F 50 to 100 C Ambient Relative Humidity 5 to 95 non condensing Alti...

Page 8: ...nting Vertical mounting normal Suitable for wall or DIN Rail mounting 6KQE Agency Approvals and Standards Compliance UL listed UL60950 cUL CE Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI C...

Page 9: ...the complete Configuration Guide for the Magnum 6KQE http www garrettcom com techsupport insertion_guides 6kqecg pdf Configuration Options Each Magnum 6KQE base unit may be configured with a choice o...

Page 10: ...m wavelength 25Km SFP ZX40 Gb SFP transceiver 1000Mb ZX 1550nm wavelength 40Km SFP ZX70 Gb SFP transceiver 1000Mb ZX 1550nm wavelength 70Km MNS 6K License MNS 6K managed software is pre loaded from th...

Page 11: ...ckage should contain 1 Magnum 6KQE Managed Edge Switch base unit configured with user selected port module options installed 2 Set of two metal vertical mounting brackets with screws to the case 1 6KQ...

Page 12: ...ened Ethernet network infrastructure connecting edge devices such as PLCs and IEDs with upstream switches or routers Designed for use in industrial applications such as factory floors and control cabi...

Page 13: ...ursty data traffic and priority streaming traffic for video surveillance and cell tower applications are present Magnum 6KQE Managed Edge Switches have heavy duty aluminum cases and are readily availa...

Page 14: ...lculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result...

Page 15: ...MNS 6K see the Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com using...

Page 16: ...t convection cooling no fans extended temperature Mounting brackets for vertical mounting are included DIN Rail mounting hardware is optional Ethernet signal and power cables attach at the bottom Two...

Page 17: ...ty of 100Mbps fiber and copper ports as well as single or dual Gigabit 1000Mb ports with industry standard LAN management software Magnum 6KQE Switches are easily used in a variety of applications inc...

Page 18: ...here the factory floors are networked with Ethernet based mixed media LANs equipped with PLCs computers for taking readings and data from Machines Client Server databases etc and sending these importa...

Page 19: ...be reconfigured and up and running in milliseconds The ring topology of the network consists of high speed LAN segments supported by 100Mbps full duplex future proof fiber media to provide a secure l...

Page 20: ...ily qualifies for this requirement with the various features and modularity it has Loaded with MNS 6K management software the edge switch provides a very effective and economical solution for the vide...

Page 21: ...loading of the building s electrical circuits 5 If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This secti...

Page 22: ...nnecting Twisted Pair CAT3 CAT5 UTP or STP The RJ 45 ports of the Magnum 6KQE can be connected to the following two media types 100BASE TX and 10BASE T CAT 5 cables should be used when making 100BASE...

Page 23: ...commended to use when making 1000BASE TX connections In either case the max distance for unshielded twisted pair cabling is 100 meters 328 ft The following procedure describes how to connect a 1000BAS...

Page 24: ...s advised not to remove and insert a SFP transceiver frequently as this may shorten its useful life Note Always use an ESD wrist strap while handling the SFP transceivers since the SFP modules are sta...

Page 25: ...oth of the devices if required If connected properly you can check via MNS 6K software for verifying the validity of SFP Gigabit ports 3 3 Mounting Dimensions for 6KQE with metal brackets Each Mangum...

Page 26: ...t it securely in a metal factory floor enclosure maintained vertically for proper convection cooling of the unit The Magnum 6KQE requires one DIN Rail bracket for secure mounting This may be ordered a...

Page 27: ...DIN Rail mounting bracket is optional and needs to be ordered as separate items e g Model DIN RAIL 6KQ 3 4 Powering the Magnum 6KQE Managed Edge Switch The DC internal power supply supports installat...

Page 28: ...ware Security violation or an S Ring Fault causes the contact to open and thus triggers an alarm in the user s monitoring system The second NC Alarm Contact is held closed when there is power on the m...

Page 29: ...http www garrettcom com techsupport sw_downloads htm 3 6 1 RS 232 DB 9 Console port Serial port pin assignments DB 9 Console port connector Pin Signal Description 1 DCD Data Carrier detect not used 2...

Page 30: ...Full duplex mode and 10Mbps or 100Mbps selection for the switched ports which must be configured through MNS software per unit as per the requirement The internal functions of both are described belo...

Page 31: ...e remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at the...

Page 32: ...en data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protrac...

Page 33: ...s 0 2 dB km ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 Magnum 6KQE Managed Edge Switch Port Modules This chapter describes each...

Page 34: ...Duplex 4 BLINKING Activity RJ45 PoE 1 ON 100Mb OFF 10Mb 2 ON Link BLINKING Link Activity 3 ON Full Duplex OFF Half Duplex 4 ON PoE device detected MTRJ Fiber 1 ON Link 2 BLINKING Activity LC Fiber 1 O...

Page 35: ...Slot C The 6KQE4 RJ45 4 port Copper module provides four 10 100Mb switched RJ 45 ports The 10 100Mb switched ports normally as a default setting are independently N way auto negotiating and auto cros...

Page 36: ...lect 10Mb or 100Mb speed and full or half duplex mode per port as per user requirements See Magnum MNS 6K Software Manual for additional info NOTE for Power Substations In support of the IEEE 1613 Cla...

Page 37: ...5 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When installed in a Magnum 6KQE Series Managed Switch the...

Page 38: ...in wiring closets while providing the advantage of future proof fiber optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly...

Page 39: ...ot C see Section 5 1 7 for more information 5 1 10 6KQE4 xSLC LC Singlemode 20km RJ45 Module The 6KQE4 xSLC 4 port Fiber Copper modules provide 100Mb Singlemode LC Fiber ports supporting distances up...

Page 40: ...e modular slot Up to two Gigabit ports maximum can be configured in Slot D only There are six LEDs provided for each Gigabit port Each Copper Gigabit port has LEDs that indicate FH Full or Half Duplex...

Page 41: ...wer pass through PoE ports are dependent upon the 48VDC input power to supply the PD power for these RJ 45 10 100 ports Each port supplies up to 15watts to power attached PoE PD devices The LEDs on th...

Page 42: ...it refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connector...

Page 43: ...URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your compan...

Page 44: ...responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants i...

Page 45: ...del with 2Gb 15 watts typical for 8 ports copper and 100Mb fiber 12VDC Power Input nominal range 8 to 18VDC 24VDC Power Input nominal range 18 to 36VDC 48VDC Power Input nominal range 36 to 60VDC 125V...

Page 46: ...y useful in the industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 125VDC options are mainly used in power utilities such as electrical substations electr...

Page 47: ...dily accessible disconnect device in the building installation supply circuit to the product Minimum 18AWG cable for connection to a Centralized DC power source 1 Minimum 14AWG cable for connection to...

Page 48: ...h at 88 150 VDC Power Supply Internal 250VDC Dual Source model Dual Src 250V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate s...

Page 49: ...age input i e the two DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is absent or even if it is connected...

Page 50: ...the terminal block always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from a ve or ve power sup...