Magnum 6K25e Gigabit Fiber Switch            Installation and User Guide (10/07)

 

 

58 

www  GarrettCom  com

.

.

APPENDIX B : Internal DC Power Supply Options 

 
B1.0 

SPECIFICATIONS FOR MAGNUM 6K25E SWITCHES, DC POWER 

 

 

Power Supply (Internal -48VDC Option) 
 

 

DC Power Connector:  3 terminals:  “

-

“, “GND”, “+” 

 

 

Input Voltage:      36 - 70 VDC  

 

    Power Consumption: Same as for AC models (see Section 1.1)  

Power Supply (Internal 24 VDC Option) Industrial Applications 
 

 

DC Power Connector:  3 terminals:  “

-

“, “GND”, “+” 

 

 

Input Voltage:      20 - 36 VDC  

 

    Power Consumption: Same as for AC models (see Section 1.1) 

Power Supply (Internal 125 VDC Option) Industrial Applications 
 

 

DC Power Connector:  3 terminals:  “

-

“, “GND”, “+” 

 

 

Input Voltage:     88 - 150 VDC  

 

    Power Consumption: Same as for AC models (see Section 1.1) 

 

   

With the exception of the power supply, all specifications and 

functions of Magnum 6K25e Switch -48VDC, 24VDC and 125VDC models are 

identical to those listed in the main manual. 

 

B2.0 

-48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

  

 

The -48VDC, 24VDC and 125VDC power options are designed using diodes 

inside on each DC power input line behind the two external power connection terminals, 

so that the power from an external 

source can only flow into the hub. 

This allows the Switch to operate 

only whenever DC power is 

correctly applied to the two inputs.  

It protects the Switch from incorrect DC input connections. An incorrect polarity 

connection, for example, will neither affect the Switch, its internal power supply, nor will 

it blow the fuse in the internal power supply.  

 

The manual power “On-Off” Switch (optional) is used for powering the unit on 

and off when it is placed into or taken out of service. 

 

B3.0 

 APPLICATIONS FOR DC POWERED SWITCHES 

 

Magnum 6K25e Fiber Switches are easily installed in a variety of applications 

where -48VDC, 24VDC and 125VDC power is used as the primary power source. The- 
48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking 
solution utilizing a special power supply in a managed Fiber Switch.  
 

The –48VDC solution is particularly useful in the telecommunication industry, 

where it is common for facilities to operate on -48VDC power. Such companies include 
regular and wireless telephone service providers, Internet Service Providers (ISPs) and 

A+

A-

GND

GND

CHASSIS

FUSE

+

-

SUPPLY

HUB

POWER  SWITCH

Summary of Contents for Magnum 6K25e

Page 1: ...i www GarrettCom com Magnum 6K25e Gigabit Fiber Switch Hardware Installation and User Guide...

Page 2: ...onal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6K25e Managed Fiber Switch contains no user serviceable parts Attempted service by unauthor...

Page 3: ...ctions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15...

Page 4: ...dia 22 3 2 1 Connecting Fiber Optic ST type twist lock 22 3 2 2 Connecting Fiber Optic SC type Snap In 23 3 2 3 Connecting Single Mode Fiber Optic 23 3 2 4 Connecting Twisted Pair RJ 45 CAT3 CAT5 23 3...

Page 5: ...45MTmulti mode FX MTRJ Small Form Factor 49 5 2 7 6KP8 MLC multi mode LC connector Small Form Factor 49 5 2 8 6KP8 45LC Combo multi mode LC small formfactor 50 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8...

Page 6: ...erformance Quad Series Fiber Switches 100 10Mbps fiber and copper ports mixed speed and mixed media types full switching performance mP62 and P62F Outdoor Ethernet SwitchES for temperature uncontrolle...

Page 7: ...ity protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted p...

Page 8: ...pe Test rating 40 to 185 F 40 to 85 C Storage 40 to 185 F 40 to 85 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating option Request quote Packa...

Page 9: ...Alarm Contact option is offered as a configuration option The two alarm contacts are SPST NC Form C relays and an open condition indicates abnormal status The Hardware Alarm monitors internal power o...

Page 10: ...eR 125VDC Same as 6K25eR except the power input is 125VDC Configuration Options Each Magnum 6K25e and 6K25eR base unit has four port module slots The first three A B C may be one of the modules below...

Page 11: ...pening in a Magnum 6K25e or 6K25eR chassis CONSOLE CBL Industry standard serial cable DB 9 connectors for RS 232 null modem connection sometimes called an Xmodem cable used to connect a PC or a charac...

Page 12: ...w PI6KP8 45RJ 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 10 100 auto negotiating auto cross RJ 45 ports New PI6KP8 45MT 4 4 port PoE module for 6ks with 48vdc PS w four...

Page 13: ...rettCom Inc as soon as possible In the event there are items missing or damaged contact the party from whom you purchased the product If the unit needs to be returned please use the original shipping...

Page 14: ...y to 802 3af PoE end devices PoE is managed by a multi stage handshake to protect equipment from damage and to manage power budgets The PoE ports will discontinue supplying power when the PoE powered...

Page 15: ...ty of applications especially using fiber media The Magnum 6K25e port modules are normally factory installed but may be changed or added in the field See Section 5 Figure 2 2 1a Regular 6K25e front vi...

Page 16: ...when OFF and the blinking ACT LED indicates receiving Activity on the port A fiber cable must be connected into a SFF port and the Link LK indicator for that port must be ON indicating there is a pow...

Page 17: ...that port Using the 6K8 Series MNS 6K management software the user may disable auto negotiation and fix the desired operation of each RJ 45 port User may select 10Mb or 100Mb speed and full or half d...

Page 18: ...an be configured in the A B or C slot of any 6K s with 48vdc power input The PoE modules are also available with mix n match with fiber modules Please check the ordering information Sec 1 2 for all th...

Page 19: ...100 copper and 2 10Mb fiber mm ST ports The 4 RJ 45 2 10 Mb ST operation of the SFF fiber and the RJ 45 half of the module is as described for those port types above For detailed information about 10M...

Page 20: ...be configured in the modular slot The Gigabit port option for the modular slot comes in couple of different configuration The Giga port has been offered as single Gigabit module comes in flavor of G 4...

Page 21: ...andwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethern...

Page 22: ...25e hardware For additional information about MNS 6K see the Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or F...

Page 23: ...select the desired mix of port types speeds The port modules are normally factory installed and tested but may be changed in the field Rack mounting may be standard or reverse 19 inch or ETSI or 23 T...

Page 24: ...normal straight cable SFP Gigabit module being supported on Slot D Due to design constrains Slot D will be populated With either Dual SFP Giga or Dual RJ 45 Gigabit or combo of both No GBIC module wi...

Page 25: ...lding The entire spread network is managed to provide easy detectable uninterrupted support through a viewable SNMP monitor Magnum QS5116 Fiber Switch GARRETT Magnum QS5116 PW Managed Fiber Switch Mag...

Page 26: ...15 16 14 12 10 8 6 4 2 F H F H 10 100 10 100 1 LK ACT LK ACT 15 16 14 12 10 8 6 4 2 F H F H 10 100 10 100 1 LK ACT LK ACT 15 16 14 12 10 8 6 4 2 F H F H 10 100 10 100 1 LK ACT LK ACT 15 16 14 12 10 8...

Page 27: ...ly adequate airflow must be maintained for proper and safe operation 3 If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly...

Page 28: ...r types are as follows IEEE Standard Media Type Max Distance Port Module Fiber 100BASE FX mm1 Fiber 220m ft GBIC SXSC sgl m2 Fiber 5Km GBIC LXSC 100BASE FX mm1 Fiber 2 0km 6 562 ft 6K6 MSC MST sgl m2...

Page 29: ...gle mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 micron...

Page 30: ...6K25e passes the 1613specifications for zero packet loss with fiber ports with RJ45 ports used as indicated here 3 2 5 Connecting Twisted Pair CAT5E or better Unshielded or Shielded The RJ 45 Gigabit...

Page 31: ...A ensuring compatibility with a wide range of networking kit Side View Duplex LC connector Front view Note It is highly recommended to remove the fiber cable first before removing the SFP transceiver...

Page 32: ...or 6K25e 6KE 2GSFP 2 SFP 6KE 2GCUSFP 1 CU 1SFP 6KE 2GCU 1GCU 2 CU 1 CU 6KE 1GSFP 1 SFP GBPM DOTX 1 GBIC Gb SFP fiber optic transceivers SFP SX Gb SX 850nm wavelength 500 m distance SFP LX10 Gb LX 1310...

Page 33: ...both sides The bracket mounting holes in the sides of the Magnum 6K25e permits it to be mounted in various ways The same holes fit all three types 19 ETSI 23 of brackets The mounting for the 23 is ill...

Page 34: ...ard 19 frame or the 23 frame or ETSI 21 frame The 19 brackets are included with each unit the other two may be purchased if desired With each bracket type there are three different mounting options is...

Page 35: ...two features occupy the same space in the case The first NC Alarm Contact top position is a Software Alarm operated by user settings in the MNS 6K software The user can disable the Software Alarm fea...

Page 36: ...warranty Caution Avoid Static Discharge The port modules like most electronic equipment are sensitive to static discharge Use proper ESD measures when handling port modules Step 1 Make sure the 6KPM C...

Page 37: ...ectors provided on the main board along with four stand off s for each 6KPM card position See Figure 3 5 1b Figure 3 5 1b Magnum 6K25e Top view without chassis cover Step 3 Remove front panel face pla...

Page 38: ...5 2a and 3 5 2b on the chassis built in stand off female provided at the front of the 6K25e Main Board and screw down tightly with the three 5 16 stand off male on the top of the Granddaughter board T...

Page 39: ...ig Fig 3 5 2d Daughter Board shown upside down with two male latch connectors Step 4 Hold the daughter board with both hands at the end and align the two cream color latching connectors male placed at...

Page 40: ...te Magnum 6K8 BLNK to cover the slot opening in the front panel This will maintain proper cooling air flow safety and operation as required by FCC CE and other regulations Step 6 Now screw down the da...

Page 41: ...A to the center standoff on the main mother board The bracket provide the stability to the Gigabit module The slot D can be configured with dual Gigabit SFP ordualRj 45 or dual combo of SFP RJ 45 modu...

Page 42: ...low the steps as described for installing a 6KPM card discussed in Section 3 5 1 3 6 Connecting the Console Terminal to Magnum 6K25e Management Use a DB 9 null modem cable to connect the Magnum6K25e C...

Page 43: ...IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console ports are intended for temporary connectivity to other equipment such as PCs Since the console port conn...

Page 44: ...ed Traffic needed for maintaining the operation of the network such as occasional multi cast packets are forwarded to all ports The Magnum 6K25e Switches operate in the store and forward switching mod...

Page 45: ...full duplex mode by MNS Software for each RJ 45 port separately For detail information See Section 10 1 at page no 52 of this manual to access the 6K MNS Rel 3 7 Software user guide One frequently us...

Page 46: ...t or the LINK is re established on a port after being lost temporarily NOTE Some NIC cards only auto negotiate when the computer system that they are in is powered up These are exceptions to the negot...

Page 47: ...et Calculations for Magnum 6K25e PM s with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fi...

Page 48: ...5 17 10 5 21 GBIC LXSC25 1000Mb Single mode 25 1550 9 125 4 0 21 15 37 5 17 5 43 GBIC ZXSC40 1000Mb Single mode 40 1550 9 125 4 0 21 15 60 17 5 70 GBIC ZXSC70 1000Mb Single mode 70 1550 9 125 3 0 23 1...

Page 49: ...Ms separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container if possible Refer to Chapter 5 fo...

Page 50: ...cates the speed if the LED is ON 100Mbps if it is OFF 10Mbps 5 2 1a 6KP6 RJ10ST 4 10 100Mbps RJ 45 and 2 10Mb multi mode FX ST twist lock Combo Module The 6KP6 RJ10ST is a six port combo module that l...

Page 51: ...rough 10Mb fiber ports It supports distances according to the 10Base FL standard i e 2Km distance for multi mode fiber Single mode for 10Km distance may be available as a special order Each port has a...

Page 52: ...imilar to the 6K6 RJMST It has the same LEDs indicating port activity ACT Link LK and FDX HDX and 10 100 operation and the same face plate lettering While the functionality of these two modules is ess...

Page 53: ...le mode Long Reach fiber network segments The 6KP6 RJSSC when installed in a Magnum 6K25e Switch has copper supporting the 100m distance and Fiber supporting single mode fiber cable lengths of as much...

Page 54: ...is 100BASE FX multi mode 8 Port module is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FDX or HDX operation 5 2 5a 6KP6 MT10ST 4 1...

Page 55: ...module The 6KP8 45MT is equipped with 4 10 100 RJ 45 ports and 4 MTRJ fiber ports When installed in a Magnum 6K25e Switch it supports the standard distances as mentioned on 5 2 3 and the LEDs also ac...

Page 56: ...i mode fiber ports When installed in a Magnum 6K25e Switch it supports the standard distances as per mentioned on 5 2 8 and the LEDs also acts similarly as mentioned above 5 2 9 6KP8 RJ45 Twisted Pair...

Page 57: ...telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6K25e It is not recommended to use these ports in substation applications to interface to field devi...

Page 58: ...In the case where the 48VDC power in not internally connected and no power is coming to the PoE ports for some reason all the PoE port LEDs are ON simultaneously to indicate a trouble condition The po...

Page 59: ...input act as a pass through so the 48VDC power source must be strong enough to provide power to the 6K switch and to all the 8 RJ 45 ports with PD devices connected up to 15 watts per PoE port In the...

Page 60: ...at full duplex The GBIC transceiver is fastened using snap in clips Insert the transceiver take care to insert it the right way up arrows on top until it clicks in space While removing the transceiver...

Page 61: ...ect these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 6K25e Sw...

Page 62: ...when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is us...

Page 63: ...in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping c...

Page 64: ...wer input line behind the two external power connection terminals so that the power from an external source can only flow into the hub This allows the Switch to operate only whenever DC power is corre...

Page 65: ...and 125VDC power terminal block on the Magnum 6K25es see figure at right In this picture the 48VDC terminal block on the Magnum 6K25e is located on the rear of the unit and is equipped with three 3 sc...

Page 66: ...add a suffix of 48VDC after the product s standard model Example Magnum 6K25eR 48VDC Similarly to order the optional 24VDC or 125VDC industrial specific power supply factory installed add a suffix of...

Page 67: ...ernal power connection terminals so that power from an external source can only flow into the unit This allows the unit to operate whenever DC power is correctly applied to either or both of the two i...

Page 68: ...power terminals positive and negative screws The use of Ground GND is optional it connects to the Switch chassis Ensure that each lead is securely tightened The 24VDC 125VDC terminal block on Magnum...

Page 69: ...63 www GarrettCom com Dual Src24V for regular models with no ON OFF switch Or Dual Src125V Switch for models with the ON OFF switch C7 0 OPERATION Operation of the Dual Source Magnum 6Ks 48VDC 24VDC a...

Reviews: