Specifications - Magnum 3024, Magnum 3012
Performance
Data Rate:
10 Mbps
RPM Partitioning:
Enforced after 32 consecutive collisions
RPM Reconnect:
Occurs after 512 bits error-free reception
BPM Auto-Learning Address List:
256 nodes capacity
BPM Filtering and Forwarding Rate:
14,880 pps max.
Maximum Ethernet Segment Lengths
DTE (AUI Drop Cable)
- 50 m (164 ft)
10BASE-T (twisted pair)
- 100 m (328 ft)
Shielded twisted pair
- 150m (492 ft)
10BASE2 ThinNet (BNC)
- 185 m (607 ft)
10BASE5 ThickNet
- 500 m (1,640 ft)
FOIRL multi-mode Fiber optic
- 1 km (3,281 ft)
10BASE-FL multi-mode Fiber optic
- 2 km (6,562 ft)
Single-mode Fiber optic
- 10 km (32,810 ft)
Network Standards
Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5,
10BASE2, 10BASE-FL & FOIRL, and DTE
Operating
Environment
Ambient Temperature:
25
º
F to 120
º
F (-5
º
C to 50
º
C)
Storage
Temperature:
-40
º
F to 185
º
F (-40
º
C to 85
º
C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 Ft. (-60 to 4000 m)
Conformal coating option: Request quote
Port Connector Types
RJ-45:
Shielded, 8-Pin Female (Note:
Shielded 10BASE-T
connectors accept either unshielded or shielded wiring
plugs for standard twisted pair media wiring.)
Fiber Optic:
ST (Twist-Lock Connector, for single and multi-mode)
Fiber Optic: SC (Snap-in Connector, for multi-mode fiber cables only)
ThinNet:
BNC
AUI:
D-Sub 15-Pin Female (with slide lock)
DTE:
D-Sub 15-Pin Male (with lock posts)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed, rear of chassis
Input Voltage: 100 - 240 vac (auto-ranging)
Input Frequency: 47 - 63 Hz (auto-ranging)
Power Consumption: Model
3024
: 18 watts typical; 30 watts max,
Model
3012
: 10 watts typical; 20 watts max,
3000-AGT
: 9 watts typical; 20 watts max,