Page 8
815 Manual
4. Mount the SpillStop indicator light (not supplied -- use a
standard clearance light) in a convenient location. Label the
indicator as an equipment monitoring light.
5. Route a single wire from each gauge to the socket housing.
Connect the gauge end of this wire to the wire coming out of
the gauge module. From the inside, seal the wire entry into
the enclosure with RTV silicon rubber. Make sure that the RTV
fully surrounds the wire where it goes though the fitting.
6. Route a single wire from the socket housing to the SpillStop
indicator light. Connect this wire to the hot side of the light,
and ground the other light terminal.
7.
Insert the plug module into the socket housing and connect
the YELLOW plug module wire to the wire from the SpillStop
indicator.
8. Wire the socket as follows:
a.
White socket terminal to ground and to the GREEN plug
module wire.
b. Blue socket terminal to the RED plug module wire.
c.
Brown socket terminal to the wire from gauge #1, and to
one of the GREY plug module wires.
d.
Green socket terminal to the wire from gauge #2, and to
one of the GREY plug module wires.
e.
Red socket terminal to the wire from gauge #3, and to one
of the GREY plug module wires.
f.
Yellow socket terminal to the wire from gauge #4, and to
one of the GREY plug module wires.
Note: If there are left over GREY plug module wires, connect
them to one of the used ones. If this is not done the indicator will
not work. For one or two gauge applications, there are two GREY
plug module wires, and for three or four gauge applications, there
are four GREY plug module wires.
9.
Wire the plug so that the socket colors can be identified at the
other end of the 7 conductor cable. Route the cable to the
SpillStop controller.
Follow these instructions for a body truck installation:
1. Route a single wire from each gauge to the SpillStop controller.
Connect the gauge end of this wire to the wire coming out of
the gauge module. From the inside, seal the wire entry into
the enclosure with RTV silicon rubber. Make sure that the RTV
fully surrounds the wire where it goes though the fitting.