T

he warranty will only apply only if the warranty card that is shipped with the equipment 
has been returned to Garnet Instruments Ltd.

DISCLAIMER OF WARRANTY ON HARDWARE

Garnet Instruments Ltd. warrants equipment manufactured by Garnet to be free from defects in 
material and workmanship under normal use and service for a period of one year from the date 
of sale from Garnet or an Authorized Dealer.  The warranty period will start from the date of 
purchase or installation as indicated on the warranty card.  Under these warranties, Garnet shall 
be responsible only for actual loss or damage suffered and then only to the extent of Garnet’s 
invoiced price of the product.  Garnet shall not be liable in any case for labor charges for indirect, 
special, or consequential damages.  Garnet shall not be liable in any case for the removal and/or 
reinstallation of defective Garnet equipment.  These warranties shall not apply to any defects or 
other damages to any Garnet equipment that has been altered or tampered with by anyone other 
than Garnet factory representatives.  In all cases, Garnet will warrant only Garnet products which 

are being used for applications acceptable to Garnet and within the technical specifi cations of the 

particular product.  In addition, Garnet will warrant only those products which have been installed 

and maintained according to Garnet factory specifi cations.

LIMITATION ON WARRANTIES

These warranties are the only warranties, expressed or implied, upon which products are sold by 

Garnet and Garnet makes no warranty of merchantability or fi tness for any particular purpose in 

respect to the products sold.  Garnet products or parts thereof assumed to be defective by the 
purchaser within the stipulated warranty period should be returned to the seller, local distributor, 
or directly to Garnet for evaluation and service.  Whenever direct factory evaluation, service or 

replacement is necessary, the customer must fi rst, by either letter or phone, obtain a Returned 

Material Authorization (RMA) from Garnet Instruments directly.  No material may be returned to 
Garnet without an RMA number assigned to it or without proper factory authorization.  Any returns 
must be returned freight prepaid to: Garnet Instruments Ltd, 286 Kaska Road, Sherwood Park, 
Alberta, T8A 4G7.  Returned warranted items will be repaired or replaced at the discretion of Garnet 
Instruments.  Any Garnet items under the Garnet Warranty Policy that are deemed irreparable by 
Garnet Instruments will be replaced at no charge or a credit will be issued for that item subject to 
the customer’s request.

If you do have a warranty claim or if the equipment needs to be serviced, contact the installation 
dealer.  If you do need to contact Garnet, we can be reached as follows:

CANADA 

UNITED STATES

Garnet Instruments Ltd. 

Garnet US Inc.

286 Kaska Road 

5360 Granbury Road

Sherwood Park, AB  T8A 4G7 

Granbury, TX  76049

CANADA   

USA

email:  [email protected] 

email:  [email protected]

CHAPTER 10 - SERVICE & WARRANTY INFORMATION

Summary of Contents for SeeLevel Special 807-ICE 05

Page 1: ..._____________________________________ MAXIMUM TANK READOUT ____________________________________________________________________ FULL SCALE ANALOG CALIBRATION VALUE ____________________________________________________ NOTES __________________________________________________________________________________________ ______________________________________________________________________________________...

Page 2: ... of Contents CHAPTER 1 INTRODUCTION 3 CHAPTER 2 FEATURES OF THE 807 ICE 05 4 CHAPTER 3 WIRING DIAGRAMS 5 CHAPTER 4 DISPLAY PROGRAMMING 6 CHAPTER 4 TROUBLESHOOTING GUIDE 8 CHAPTER 10 SERVICE WARRANTY INFORMATION 9 MAIL IN WARRANTY 11 807 ICE 05_v8 2 11 Aug 2017 TM ...

Page 3: ...put proportional to the fluid volume displayed This analog output can be used to com municate the tank level to other pieces of equipment The full scale value of the analog output can be set using the but tons on the back of the display no additional equipment is re quired for calibration The 807 ICE 05 display has been designed to withstand the vibra tion and shock encountered in mobile applicati...

Page 4: ... to 60 C 40 F to 140 F ambient temperature 5 Easy installation and servicing with a one year limited war ranty Additional 807 ICE 05 Remote Display Features 1 An analog 0 5V output with 0V corresponding to zero dis played volume and 5V corresponding to the full scale dis played volume programmed into the remote display 2 The model 807 ICE 05 provides an easy to read LED display inside a compact ed...

Page 5: ...for easy installation with your 808 or 810 series SEELEVEL gauge Installation instruc tions for the gauge were supplied with the equipment and are available online at www garnetinstruments com The 807 ICE 05 Remote Display is easy to install 808 P2 Wiring Diagram 810 PS2 Wiring Diagram ...

Page 6: ...ttons on the back panel the display will show ACAL Release both buttons 3 The display will show the existing calibration with the left digit bright Press the UP button to change the bright digit Press the SEL button to go to the next digit 4 Set all 4 digits then press SEL again to set the decimal point it will be bright to indicate that it is selected Press the UP but ton to select either x xxx x...

Page 7: ...on the back panel the display will show the existing full scale analog cali bration while the button is held down Release the button to return to normal operation To test the analog output 1 While either the SEL or UP button on the back panel is pressed the display will show the full scale calibration and the analog output will go to full scale 5V This can be used to test or calibrate the equipmen...

Page 8: ...ing for errors or bad connections Also ensure that the 808 P2 or the 810 PS2 is working properly 6 For either condition 3 or 4 the display will need to be serviced or replaced Accuracy The analog output has an accuracy of 0 5 of the full scale val ue so any output value should be within 25 mV of the ideal value There are no user adjustments that can be made to alter the accuracy As with any digita...

Page 9: ...TATION ON WARRANTIES These warranties are the only warranties expressed or implied upon which products are sold by Garnet and Garnet makes no warranty of merchantability or fitness for any particular purpose in respect to the products sold Garnet products or parts thereof assumed to be defective by the purchaser within the stipulated warranty period should be returned to the seller local distribut...

Page 10: ...Page 10 807 ICE 05 Manual NOTES ...

Page 11: ...NUMBER OF EACH UNIT IT IS DIFFICULT TO DETERMINE WARRANTY VALIDITY DEALERS NAME WARRANTY CONTACT ADDRESS TELEPHONE FAX IN UNITED STATES RETURN TO Garnet US Inc 5360 Old Granbury Road Granbury TX 76049 USA IMPORTANT RETURNING THIS CARD WILL ENABLE US TO NOTIFY YOU IN THE EVENT OF A PRODUCT RECALL OR TO SUPPLY YOU WITH REQUIRED PRODUCT SAFETY INFORMATION TO MAXIMIZE YOUR WARRANTY PLEASE REGISTER ONL...

Page 12: ...uments com CANADA Garnet Instruments Ltd 286 Kaska Road Sherwood Park AB T8A 4G7 USA Garnet US Inc 5360 Old Granbury Road Granbury TX 76049 P 780 467 1010 F 780 467 1567 TF 1 800 617 7384 P 817 578 8601 F 817 573 0005 TF 1 877 668 7813 ...

Reviews: