Step Six (Fill Cylinder)
You will need the motor in the down position and
the cylinder fittings pointing straight up.
Disconnect the rod end of the cylinder from its
mount. Find the kinked piece of tubing that you
removed in step one. Remove the tie wrap and cut
the tubing in half. Push one half on each cylinder
barbed fitting. Open the fluid bottle. Insert pieces
of tubing into the fluid. They need to go to the
bottom of the bottle. Now hold the tubing in the
bottle with one hand and pull and push the rod in
and out of the cylinder until you stop seeing air
bubbles in the hose. Refer to fig. 16
Fig. 16
Fig. 17
Slide the rod into the cylinder as far as it will go. Now remove the short clear hose from the cylinder and
drain the fluid from the tubing into the bottle. Be sure both cylinder fittings are full to the top. Point the
rod end of the cylinder toward the pin that engages it but leave it pushed into the cylinder.
Step Seven (Correctly connect the hose)
At the cylinder, kink the black hose (bend it
over sharply and use a tie wrap to pinch hose
shut). See Fig. 17. Cut the hose as shown just
above the tie wrap and keep a thumb over the
right side to keep the fluid in the hose. Keep
the hose full to the brim and push the right
hose (hose that has tape) onto the right cylinder
fitting as shown in Fig.17-A
Cut the tie wrap on the left hose and insert it on
the left fitting on the cylinder as shown in
Fig.17-B. Reconnect the cylinder rod end.
Fig. 17-A Fig. 17-B
17
17