190-01279-01
GTS 8XX Part 23 AML STC Maintenance Manual
Rev. 2
Page 7-4
7.3.1.1 Normal Tab
The
Normal
tab, shown in
Figure 7-1, displays GTS 8XX
system status during normal
operation, including operating
status, antenna alpha values,
system faults, and status flags. The
Normal
tab is also used to enable
or disable GTS 8XX system
ground test. When the
Normal
tab
is selected, the GTS 8XX reboots
into Normal System mode.
Operating Status
The
Normal
tab’s Operating
Status portion displays the
GTS 8XX total power-on count
and time, as well as the current
temperature of the GTS 8XX.
Alpha Values
Alpha values are phase measurement values for the top and bottom antennas used to determine if the
installation has an adequate ground plane for each antenna. Alpha values are updated after a self-test is
performed.
System Faults
GTS 8XX system faults are listed in the System Faults column of the
Normal
tab, shown in Figure 7-1.
Red bold text indicates an active fault. Gray text indicates an inactive fault. See Section 5.3 for GTS 8XX
system fault descriptions.
Status Flags
GTS 8XX system status flags are listed in the Status Flags column of the
Normal
tab, shown in
Figure 7-1. Black bold text indicates a status flag that has been set. Gray text indicates a status flag that has
not been set. Status flags are described in Table 7-1.
Figure 7-1 GTS Processor Install Tool - Normal Tab