![Garmin GNC 420 Maintenance Manual Download Page 30](http://html1.mh-extra.com/html/garmin/gnc-420/gnc-420_maintenance-manual_3740566030.webp)
Page 3-4
400 SERIES MAINTENANCE MANUAL
Rev. C
P/N 190-00140-05
F501
1 AMP
J6
F502
1 AMP
Figure 3-4. Nav Board Fuse Locations
3.3.2
Power Supply Checks
3.3.2.1
Current Measurements
Taking intra-board and external current measurements is one way of determining a faulty board.
To measure the currents, use a spare ribbon cable and spread the cable wires, then use a DC probe
to measure the current in the appropriate wire (connector pin). The following external and
intra-board current measurements can be taken during troubleshooting (the intra-board currents
are given as reference):
x
Com Board (Tables 3-2 and 3-3):
J26: Intra-board (Main Board to Com Board)
J2: External Connector
x
Glideslope Board (Table 3-4):
J25: Intra-board (Nav Board to Glideslope Board)
x
Nav Board (Table 3-4):
J10: Intra-board (Main Board to Nav Board)
J6: External Connector