190-01182-02
GTR 225/GNC 255 TSO Installation Manual
Rev. F
Page 5-13
5.2.9
RMI/OBI
5.2.9.1
RMI/OBI Function
VOR OBI output provides bearing information from the currently tuned VOR station for Bendix/King
Serial OBI devices based upon the VOR receiver. When a localizer channel is tuned on the VOR/LOC
window, there is a bit in the data stream set to indicate that a localizer frequency is tuned which stows the
needle or drives it to the three o’clock position.
5.2.9.2
RMI/OBI Electrical Characteristics
The output driver is an Active-Low. The driver output voltage is not more than 1.0 V when sinking 20 mA.
The maximum off state leakage current with respect to ground is less than 10
μ
A.
Pin Name
Connector
Pin
I/O
VOR OBI CLOCK
P2002
25
In
VOR OBI SYNC
P2002
26
In
VOR OBI DATA
P2002
27
In