Network Status Icons
A network-status icon is shown on some screens of the device. You can refer to this table to understand the
appearance of the icon and help diagnose issues with the Fusion PartyBus network.
The device is connected correctly to a network.
The device cannot detect the network. An Ethernet cable may not be connected or there may be other
problems with the network.
Specifications
Dimensions (W × H)
11 × 7 cm (4.32 × 2.76 in.)
Dust cover dimensions (W × H)
11.8 × 8 cm (4.66 × 3.15 in.)
Weight (excluding cable)
100 g (3.5 oz.)
Input voltage
From 10.8 to 32 Vdc negative ground
Current (normal operation at 12 Vdc)
150 mA
Current (normal operation at 14.4 Vdc)
125 mA
Current (device off)
Less than 50 mA
Fuse
1 A ATO blade-type
Compass-safe distance
15 cm (6.1 in.)
Operating temperature
From 0 to 50°C (from 32 to 122°F)
Storage temperature
From -20 to 70°C (from -4 to 158°F)
Water rating
IEC 60529 IPX6 and IPX7
1
1
The device withstands incidental exposure to water of up to 1 m for up to 30 min, and is protected against powerful jets of water. For more information, go to
12
More Information
Summary of Contents for Fusion Apollo MS-ERX400
Page 1: ...FUSION Apollo MS ERX400 O W N E R S M A N U A L ENGLISH...
Page 4: ......