background image

Garland Commercial  

Industries, LLC

185 East South Street

Freeland, PA 18224

Phone: (570) 636-1000

Fax: (570) 636-3903

Garland Commercial Ranges Ltd

1177 Kamato Road,  

Mississauga, Ontario  

L4W 1X4 CANADA

Phone: 905-624-0260

Fax: 905-624-5669

Enodis UK LTD

Swallowfield Way,  

Hayes, Middlesex  

UB3 1DQ ENGLAND

Telephone: 081-561-0433

Fax: 081-848-0041

34-1/2"

[876mm]

1-1/2"

[38mm]

1"

 N.P.T.

REAR GAS

INLET

23-1/4"

[590mm]

11-3/4"

[300mm]

TYP

59"

[1500mm]

8-1/4"

[210mm]

18-3/8

[466mm]

23-5/8"

[600mm]

12.3/4"

[324mm]

38-3/8"

[974mm]

6"

[152mm]

13-7/8"

[352mm]

ADD WHEN

DOOR OPEN

31-1/8"

[791mm]

12-1/8"

[307mm]

51"

[1296mm]

STD BACKGUARD

W/HIGH SHELF

2-1/2"

[57mm]

3-1/4"

[82mm]

27-1/4"

[692mm]

4"

[102mm]

1-3/4"

[45mm]

41"

[1041mm]

LOW PROFILE

BACKGUARD

X S
er

ies 60" R

aised Gr

iddle/Br

oiler G

as R
ange

Form# XRB60 Series (09/02/08)

Model

Number

Description

Total 

BTU/Hr

Natural

Shipping  

Information

Lbs.

Kg

Cu Ft

X60-6R24SS

6 Open Burners, 24" Raised Griddle/Broiler w/ Double Storage Base

213,000

662

300

81

X60-6R24RR

6 Open Burners, 24" Raised Griddle/Broiler w/ (2) Standard Ovens

279,000

828

376

81

X60-6R24RS

6 Open Burners, 24" Raised Griddle/Broiler w/ (1) Standard Ovens & Storage Base 246,000

787

357

81

Width 

In (mm)

Depth 

In (mm)

Height 

w/shelf 

In (mm)

Oven Interior-in (mm)

Combustible Wall 

Clearance-In (mm)

Entry Clearances

In (mm)

Manifold Operating 

Pressure

Height Depth Width

Sides

Rear

Crated

Uncrated

Natural

Propane

59-1/16

 

(1500)

33-1/2

 

(8512

57

 

(1448)

13

 

(330)

22 

(559)

26-1/4

 

(667)

14

 

(356)

(152)

37 

 

(940)

36-1/2

 

(927)

4.5" WC

 

11 mbar

10"

 

25 mbar

Burner Ratings (BTU/Hr/kW)

Gas 

Type

Open Top

Hot Top

Standard 

Oven

Raised  

Griddle/Broiler

Natural

30,000/8.79 18,000/5.27

33,000/9.67

33,000/9.66

Propane 26,000/7.61 18,000/5.27

29,000/8.50

33,000/9.66

Note: Installation clearance reductions are appli

-

cable only where local codes permit.
This product is not approved for residential use. 

Gas input ratings shown for installations up to 2000 

ft.,(610m) above sea level. Please specify altitudes 

over 2000 ft.

Reviews: