8. TROUBLESHOOTING
Depending on the symptons that you observe, you can probably know the cause of the problem and could even
solve it:
If after carrying out these checks the pump still does not work correctly, take the pump to a technical service.
Failure
Symptom
Action
The engine does not
work
The LCD screen is off.
The machine is not connected to power. Plug the machine
into power.
The cable is damaged. Send the machine to technical
service. Never repair the cable with electrical tape.
Internal fault. Send the machine for service
LCD screen works but
motor does not turn
The pump is in “Power On” mode. Change to Continuous
Mode “Ever - On Mode” and check that it works.
If the pump does not work in Continuous Mode unplug
the machine, remove the filter and check that there are
no objects blocking the rotation of the turbine. Clean
everything, clean the filter and retest.
If the engine still does not work, send the machine for
service.
Overload protection activated. Let cool 15 minutes.
The engine runs but
does not pump water
or pumps little
No water comes out
Stopcocks closed. Open the keys.
Water below the minimum suction level. Stop the pump
and lower the height of the pump relative to the water.
Suction pipe takes air. Check the tightness of the suction
pipe.
Incorrect priming of the machine. Follow the steps in
section 6.2.1
Excessive height of the water outlet point that exceeds
the capacities of the pump. Decrease the height of the
exit point.
Little water comes out
Dirty filter. Clean the filter.