EXPLANATION OF CONTROLS (Standard Models)
60
55
50
45
40
35
30
25
20
15
LOW
Mechanical Control, (Standard Models
)
Moisture Control
This controls the duration of the moisture injection into the
oven cavity . This is a rotary dial .
Moisture Switch
This rocker switch has three positions . The center position is
OFF . This shuts off electrical power to the moisture system .
The AUTO position energizes the system until the switch is
turned off . This activates the injecting timer at the intervals
manually set with the moisture control . The MANUAL position
is momentary . Pressing will cause the moisture injector to
inject moisture .
Fan Speed Switch
The left rocker switch, the fan speed switch, has two positions .
The motor and fan can be run at either high speed, (1725
RPM), by pressing the switch upward to HI, or low speed,
(1140 RPM), by pressing the switch downward to LO .
Power Switch
The right rocker switch . This main control switch has three
positions . The center position is OFF . This shuts off electrical
power to all functional components . The COOK position
energizes the timer, thermostat and moisture functions . The
COOL DOWN position energizes the motor and fan only .
Light Switch
This switch activates the oven interior light . This is a
momentary switch . The light will stay lit as long as this button
is held in the on position . The light will operate in any mode,
whenever there is electrical power connected to the oven .
Temperature
The temperature range is from 150°F, (66°C), to 500°F, (260°C) .
Temperature is controlled by aligning the indicator to the
desired temperature .
Timer
The timer is set by rotating the dial clockwise aligning the
indicator to the desired time cycle . At the end of the timing
cycle, a buzzer will sound . The buzzer is turned off by rotating
the dial counterclockwise to the OFF position . The buzzer will
sound continuously until manually turned off .
Summary of Contents for moisture+ MP-GD-10-S
Page 2: ...Part MPSM07 03 24 08 Page ...
Page 4: ...Part MPSM07 03 24 08 Page ...
Page 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual ...
Page 38: ...Part MPSM07 03 24 08 Page 38 ...
Page 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service ...
Page 60: ...Part MPSM07 03 24 08 Page 60 ...
Page 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List ...
Page 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS ...
Page 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE ...
Page 77: ...Part MPSM07 03 24 08 Page 77 ...
Page 78: ...Part MPSM07 03 24 08 Page 78 ...
Page 79: ...Part MPSM07 03 24 08 Page 79 ...
Page 80: ......