Part # 4521357 (12/07)
Page 6
Table D: Injector Size
MODEL/
SECTION
G20/G25 @ 20/25 mbar
(NATURAL)
G31 @ 37mbar
(PROPANE)
G31 @ 50 mbar
(PROPANE)
Injector Size
Injector Size
Injector Size
I.D. #
mm
I.D. #
mm
I.D. #
mm
All
43
2 .3
53
1 .5
54
1 .4
NOTE:
The pressure must be measured at the pressure test nipple located on the main manifold pipe
with all burners lit .
Table E: Setting Pressure For “Min” Tap Position
MODELS
2ND Family, Group H
3RD Family, Group 3P
(G20 @ 20 mbar) NATURAL GAS
(G31 @ 37/50 mbar) PROPANE
mbar
“ W.C.
mbar
“ W.C.
ALL
1 .25
0 .5
2 .49
1
Table F: Aeration Shutter Setting / Pilot Flame Length
MODELS
2ND Family, Groups H,L & E.
3RD Family, Group 3P
Pilot Flame Length
( G20/G25 @ 20/25 mbar)
NATURAL GAS
( G31 @ 37/50 mbar ) PROPANE
mm
Ins.
mm
Ins.
mm
Ins.
ALL
19
0 .75
27
1 .062
12 .5
0 .5
Table G: Australia Only – Injector Size, NGC And Pressure
MODELS
NATURAL GAS
PROPANE GAS
Inj. Dia
mm
MJ/H
Gas
Pressure
(kPa)
Inj. Dia.
mm
MJ/H
Gas
Pressure
(kPa)
G24-24GSFD
2 .85
63 .3
1 .0
1 .7
63 .3
2 .49
G24-36GFSD
2 .85
95 .0
1 .0
1 .7
95 .0
2 .49
G24-48GFSD
2 .85
126 .6
1 .0
1 .7
126 .6
2 .49
G24-60GFSD
2 .85
158 .3
1 .0
1 .7
158 .3
2 .49
G24-72GFSD
2 .85
189 .9
1 .0
1 .7
189 .9
2 .49
TECHNICAL SPECIFICATIONS continued